Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

BL-983314-1

BL-983314-1
Panel mounted resistivity mini controller 115/230V
HANNA Instruments BL-983314-1
The BL-983314 is ideal for continuous monitoring of process solutions. Setpoint and calibration are manually adjusted with a trimmer, and the alarm relay allows for simple control. Adjustable dry cont

Overview

The BL-983314 is ideal for continuous monitoring of process solutions. Setpoint and calibration are manually adjusted with a trimmer, and the alarm relay allows for simple control. Adjustable dry contact dosing relay The BL-983314 features a dosing relay that is activated when the reading is below a user programmable set point.

Programmable Overdose Protection For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled. Relay Control Override With the flick of a switch, the mini controller's relay can be disabled (off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.

Multicolour LED Indicator Multicolour LED indicator allows an operator to quickly check the status of the controller. Green = Meter in measurement mode and reading is above the set point. Orange/Yellow = Reading is below the set point and the relay is activated.

Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded. Fuse Protected Dosing Contacts The relay dosing contact is rated for up to a 2A load and is fuse protected. Labelled Termination Connections Quick-connect terminal blocks are clearly labelled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.

Specifications

ParameterValue
SKUBL-983314-1
Range0.00 to 19.90 MΩ•cm
Resolution0.10 MΩ•cm
Accuracy(@25°C/ 77°F) ±2% F.S.
Temperature Compensationautomatic and linear from 5 to 50°C
Temperature Coefficientβ=2.4 ; 3.5 ; 4.5 %/°C selectable through jumper on the rear panel
Calibrationfactory calibrated
Dosing Relaymaximum 2A (fuse protected), 250 Vac, 30 VDC contact closed when measure below setpoint
Setpointadjustable from 0 to 19.90 MΩ•cm
Overtimeadjustable, typically from 5 to approximately 30 minutes
Power SupplyBL983314-1: 115/230 VAC; 50/60Hz input: 10 VA for 115/230 VAC, 50/60 Hz models; 3 W for 12 VDC models; fuse protected; installation category II.
Dimensions:83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’)
Weight:BL-983314-1: 300 g (10.6 oz.)
Ordering Information:BL983314-1 (115/230V) is supplied with mounting brackets, transparent cover and an instruction manual.
Recommended Probe:HI-3314 resistivity probe with 2 m (6.6’) cable (included)