Overview
This design consideration is ideal for measuring the pH in municipal and industrial wastewater, swimming pools, and various field applications. Titanium Body Built-In Temperature Sensor Extendable Cloth Junction The HI-1297D is a pH/ORP electrode for wastewater, municipal water, water treatment and swimming pools. The HI-1297D uses general purpose (GP) glass, spherical bulb, titanium body, and cloth junction with gel electrolyte.
General Purpose Glass Formulation General Purpose (GP) glass, as the name implies, is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25°C and is suited for measuring pH of samples that are at ambient temperatures. The HI-1297D is suitable to use with samples that measure from 0 to 80°C.
Spherical Bulb The spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements. Titanium Body A titanium body increases immunity to electrostatic and magnetic fields.
It also allows for strong corrosion resistance, even in seawater. Our titanium bodied electrodes’ outer casings also serve as a matching pin. A matching pin is a differential measurement technique used to eliminate ground loops and common mode perturbations for the measurement system.
In a system without a matching pin, electrical currents in the samples can affect the reference half cell voltage. The matching pin isolates these current/magnetic fields from the reference electrode for safe, precise pH measurements. Cloth Junction This type of junction is often used on electrodes with gelled electrolytes.
The advantage of this junction is it is renewable; as the cloth-like material is pulled out from its position, the junction is renewed with an uncontaminated, fresh surface. DIN Connector The HI-1297D uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable.
Other types of connectors include BNC, screw type, T-type, and 3.5mm to name a few.
Specifications
| Parameter | Value |
|---|---|
| SKU | HI1297D |
| Reference | single, Ag/AgCl |
| Junction/Flow Rate | cloth |
| Electrolyte | gel |
| Max Pressure | 3 bar |
| Range | pH: 0 to 13; ORP |
| Recommended Operating Temp. | 0 to 80°C |
| Tip/Shape | pH: conic (3 mm); ORP: platinum sensor |
| Temperature Sensor | yes |
| Amplifier | yes |
| Body Material | titanium |
| Cable | 7-pole; 1 m (3.3') |
| Connection | DIN |
Accessories
- HI-7004L: HI-7004L pH 4.01 Buffer Solution, 500 mL bottle
- HI-7007L: HI-7007L pH 7.01 Buffer Solution, 500 mL bottle HI7007
- HI-7010L: HI-7010L pH 10.01 Buffer Solution, 500 mL bottle
- HI-70300L: HI-70300L pH Electrode Storage Solution, 500 mL
- HI-7061L: HI-7061L Electrode Cleaning Solution - General Purpose, 500mL
Related Products
HANNA InstrumentsT-Type Glass Body pH Electrode
HANNA InstrumentsPotassium Combination ISE Electrode
HANNA InstrumentsORP electrode with PTFE junction, Pt sensor, BNC 5m cable
HANNA InstrumentsIndustrial Flat Tip pH Electrode, PTFE junction, low temperature
HANNA InstrumentsGeneral Purpose Penetration Probe
HANNA InstrumentspH Electrode with Temperature Sensor
HANNA InstrumentsIndustrial Flat Tip ORP electrode, PTFE junction, Pt sensor, BNC
HANNA Instruments