Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI2202

HI2202

Bluetooth smart pH meter

Bluetooth system pH-temperature °C meter
  • Innovative global design pH meter with Bluetooth smart technology

  • The Bluetooth electrode connects quickly to the H2202 (edgeblu) meter with one button press, and the electrode name and built-in electrode battery status are displayed on the meter interface; blue indicator light, built-in temperature sensor and microprocessor amplifier, equipped with Bluetooth smart technology, eliminating cable length constraints, enabling measurement data to be transmitted directly on-site or in the laboratory within a 10-meter range.

Powerful management functions

  • Unique automatic electrode type recognition, automatically enters the measurement item mode, the electrode sensor automatically stores calibration data, automatically recalls and queries GLP stored data, CAL-CHECK electrode verification system, prompts electrode contamination and standard buffer information, and timely reminds of the pH electrode status (good, damaged) and electrode connection status.

  • GLP records the last calibration information, including calibration date and time, buffer 1 standard solution, and stores this information in the electrode. When a smart Bluetooth electrode with stored GLP information is connected to another H12202 meter, the GLP data in the electrode is automatically transmitted to the instrument, achieving automatic matching between electrode and instrument without the need for recalibration.

Data management functions

Up to 1000 data sets (basic mode: 400 sets) including measurement data, GLP data, time and date; manual spot storage of 200 data sets, manual continuous storage of 200 data sets, time interval (automatic 600, manual 100 sample storage), USB data interface for measurement data output, micro USB interface for data transmission and charging, ensuring further analysis and management of measurement data.

On-screen operation step prompts

Concise full-text information prompts are displayed at the bottom of the screen, abandoning troublesome abbreviations, making operation convenient and quick.

Extra-large screen, ultra-thin design, touch operation

Ultra-light and portable, 12.7 mm ultra-thin body, 250 g lightweight design, stylish and beautiful touch buttons, integrated screen and button design, keeping you away from sample residue on the keypad and preventing sample damage to the operation panel. 5.5-inch extra-large viewing angle LCD screen, 150° viewing angle, measurement data clearly visible within 5 meters.

Custom dedicated holder

Enables flexible adjustment of the electrode to the suitable measurement position and the display to a visible angle. Can be used suspended with the holder, used on a benchtop, or handheld without the holder. Space-saving and easy to carry.

pH Technical Specifications

Measuring range

-2.00 to 16.00 pH, -2.000 to 16.000 pH; pH-mV conversion: ±1000 mV

Resolution

0.01 pH, 0.001 pH, 0.1 mV

Accuracy@25°C/77°F

±0.01 pH, ±0.002 pH, ±0.2 mV

Calibration mode

Three-point or five-point automatic recognition calibration and two custom calibrations, built-in pH standard calibration points: 1.68, 4.01, 3.00, 6.86, 7.01, 9.18, 10.01, 12.45 pH

Temperature compensation Automatic temperature compensation, -5.0 to 100.0°C; -23.0 to 212.0°F
Electrode diagnostics

Electrode condition, response time, calibration expiration reminder

Temperature Technical Specifications

Measuring range

-20.0 to 120.0°C; -4.0 to 248.0°F

Resolution/Accuracy

Resolution: 0.1°C, 0.1°F; Accuracy: ±0.5°C, ±0.9°F

Other Technical Specifications

Standard electrode

HI11102 smart Bluetooth glass composite pH electrode with built-in temperature sensor, Bluetooth transmission distance ≤10 meters
Note: You can select the appropriate Bluetooth pH electrode according to different measurement items

Data storage

Automatic storage of 1000 data sets, interval storage of 200 data sets; manual storage of 600 data sets

Interface type

1 USB port for data storage; 1 micro USB port for charging and computer data transmission

Power supply

Built-in rechargeable battery, 5V power adapter and multi-function charging holder

Operating environment

0 to 50 °C (32 to 122 °F) max. RH 95% non-condensing

Dimensions and weight

Meter dimensions: 202 x 140 x 12 mm (7.9" x 5.5" x 0.5"), meter weight: 250 g (8.82 oz.)

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.