HI-7024 Pool Line Copper High Range Checker Designed as a more accurate alternative to chemical test kits, the HI-7024 provides quick, accurate results in four easy steps. HI-7024 uses an adaptation of the EPA method. The reaction between copper and the bicinchoninate reagent causes a purple tint in the sample.
Key features Small palm-sized design Accurate from ±0.05ppm ±5% of reading Dedicated to a single parameter Auto power off after 10 minutes of inactivity Built-in timer for timed reaction readings About Copper If the concentration of free copper is too high in bathing, blond hair can turn green. The maximum concentration of free copper in a bath is 0.8 mg / l. The HI-7024 is a simple, accurate and affordable way to measure copper values.
This checker uses an adaptation of the EPA method. Order Information The HI-7024 Pool Line Copper high range Checker is supplied with sample cuvettes and caps (2), Copper HR reagent starter kit x 6 tests, battery, instructions and quick start guide. Also available: HI-7024-11 Calibration set.
Replacement HI-7024-25 Reagents 25 tests. Four easy steps to testing Step one – Add a sample to the included cuvette Step two – Insert sample into the Checker HC and press the button to zero Step three – Remove sample and add reagent as stated in the manual Step four – Reinsert sample and press the button to measure your results Safety Data Sheets When using any form of chemical, such as Hanna reagents, it is important you download the relevant safety data sheet and make yourself aware of any precautions you should take when handling the chemical. You can access our library of safety data sheets and download a copy by following the link below.
Please note that the '-' in HI- products should be removed from all searches to find the correct information. CLICK HERE
Specifications
| Parameter | Value |
|---|---|
| SKU | HI7024 |
| Range | 0.00 to 5.00 ppm |
| Resolution | 0.01 ppm |
| Accuracy @ 25°C | ± 0.05 ppm ± 5% of reading |
| Light Source | LED @ 575 nm |
| Light Detector | Silicon photocell |
| Environment | 0 to 50°C; RH max 95% non-condensing |
| Battery Type | (1) 1.5V AAA |
| Auto-off | After 10 minutes of non-use |
| Dimensions | 86 x 61 x 37.5 mm |
| Weight | 64 g |
| Method | adaptation of the EPA method. The reaction between copper and the bicinchoninate reagent causes a purple tint in the sample |
Manuals and documentation
Related Products
HANNA InstrumentsPool and Spa Controller
HANNA InstrumentsTotal Chlorine Buffer Solution - PCA, 500ml
HANNA InstrumentsPCA320 Free & Total Chlorine, pH and Temperature Analyser
HANNA InstrumentsFree & Total chlorine, pH & °C controller/analyser
HANNA InstrumentsFree chlorine reagents set for PCA, 500ml (2), plus 5 sachets (DPD)
HANNA InstrumentsInjection saddle for 63 mm pipe diameter half-inch thread
HANNA InstrumentsFree and Total Chlorine Portable Photometer
HANNA Instruments