Overview
Hanna's cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction. HI-7061-023 GroLine General Purpose Cleaning Solution, 230 mL Electrodes can become dirty from use and will produce inaccurate results even if they read correctly in a pH buffer.
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardisation curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV.
The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.
Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI-7061-023 cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings. Key Features Specially formulated for cleaning electrodes Air tight bottle with tamper-proof seal to ensure the quality and freshness of solution Each bottle is marked with a lot number and expiry date.
Hanna recommends using HI-50036p Groline Quick Cal Solution alongside this product.
Specifications
| Parameter | Value |
|---|---|
| SKU | HI7061-023 |
| Description | general purpose cleaning solution |
| Package | bottles |
| Size | 230 mL |
| Quantity | 1 |
| Certificate of Analysis | No |
Accessories
- HI-7004-023: HI-7004-023 GroLine pH 4.01 Calibration Buffer, 230 mL
- HI-7007-023: HI-7007-023 GroLine pH 7.01 Calibration Buffer, 230 mL
- HI-7061-023: HI-7061-023 GroLine Cleaning Solution, 230 mL
- HI-70300-023: HI-70300-023 GroLine Electrode Storage Solution, 230 mL
Related Products
HANNA InstrumentsGroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester
HANNA InstrumentsGroLine Cleaning Solution for pH electrodes, 120ml
HANNA InstrumentsGroLine pH/Conductivity probe with built-in temperature sensor DIN connector and 1m cable
HANNA InstrumentsActivation & Cleaning Solution for HI-83900 Lysimeters, 500ml
HANNA InstrumentsGroLine pH dosing system with HI-10063 pH probe
HANNA InstrumentsCleaning Solution for Soil Deposits (Agriculture), 25 x 20 mL sachets
HANNA InstrumentsGroLine Nutrient dosing system with HI-30033 conductivity probe EC/TDS/Temp
HANNA Instruments