Overview
HI-7214 Pool Line Iron Checker® Handheld colorimeter About iron About 6.3% of the earth’s crust is made of iron with 43% of this amount held in the soil. As a result, iron is naturally present in most water supplies. Left in the water, iron will stain pipework and swimming pool, hot tub and spa surfaces, causing brown spots, cloudiness or brown water.
Testing should therefore form an important part of any water monitoring process in your swimming pool, hot tub or spa with the maximum concentration of iron in a bath being 0.2 mg /L. Key features Accurate and easy to use Phenanthroline method Accuracy ±0.04 mg/L (ppm) 0.01 mg/L (ppm) resolution Designed to work with Hanna reagents Large, easy to read digits Auto shut-off Fits into the palm of your hand Supplied with: 2 sample cuvettes and caps Starter pack of 6 reagents for Iron (re-ordering information HI-7214-25 x 25 tests) 1 x 1.5V AAA battery Instructions Four steps. One click.
Instant Readout. 1. ‘Zero’ the Checker®HC with your vial inside 2.
Place a 10ml water sample into the vial and add your reagent 3. Place your vial into your Checker®HC 4. Press the button and read the results Use calibration check set HI-7214-11 with the HI-7214 Pool Line High Range Iron Handheld Colorimeter - Checker®HC.
Use reagent HI-7214-25 with the HI-7214 Pool Line High Range Iron Handheld Colorimeter - Checker®HC, 25 tests. Safety Data Sheets When using any form of chemical, such as Hanna reagents, it is important you download the relevant safety data sheet and make yourself aware of any precautions you should take when handling the chemical. You can access our library of safety data sheets and download a copy by following the link below.
Please note that the '-' in HI- products should be removed from all searches to find the correct information. CLICK HERE
Specifications
| Parameter | Value |
|---|---|
| SKU | HI7214 |
| Range | 0.00 to 5.00 ppm (mg/L) |
| Resolution | 0.01 ppm (mg/L) |
| Precision | 2% of reading ±0.04 ppm (mg/L) @ 25°C |
| Light Source | LED @ 525 nm |
| Light Detector | Silicon photocell |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
| Battery Type | (1) 1.5V AAA |
| Auto-off | After 2 minutes of non-use and after read |
| Dimensions | 86 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) |
| Weight | 64 g (2.25 oz.) |
| Method | Adaptation of EPA Phenantroline method 315B, for natural and treated waters. The reaction between iron and the reagent will cause an orange tint to the sample. |
| PLEASE NOTE: | In some cases, samples may contain other parameters which may interfere with results |
| Interferences may be caused by: | Alkalinity: above 2,000 mg/L (as CaCO 3 ). May slow down colour development (negative error). To resolve this, neutralise the sample with diluted HCl. Calcium (Ca 2+ ): above 10,000 mg/L as CaCO 3 Copper (Cu 2+ ): does not interfere: reagent contains a masking agent. Magnesium (Mg 2+ ): above 100,000 mg/L as CaCO 3 Molybdate Molybdenum: above 25 mg/L (as Mo-MoO 4 ) (positive error) Sample containing up to 50 mg/L Mo-MoO 4 may be measured if a reading is taken after 1 minute instead of 3 minutes. High Iron concentrations up to 200 mg/L do not inhibit colour development; above 200 mg/L colour development may be inhibited. High sulphide concentrations (S 2- ): high sulphide concentrations may interfere. To reduce sulphide: acidify the sample and boil for about 20 minutes, neutralise and adjust volume before measurements. Silica (SiO 2 ): above 175 mg/L (as SiO 2 ). May slow down colour development (negative error) |
Manuals and documentation
Related Products
HANNA InstrumentsPool and Spa Controller
HANNA InstrumentsTotal Chlorine Buffer Solution - PCA, 500ml
HANNA InstrumentsPCA320 Free & Total Chlorine, pH and Temperature Analyser
HANNA InstrumentsFree & Total chlorine, pH & °C controller/analyser
HANNA InstrumentsFree chlorine reagents set for PCA, 500ml (2), plus 5 sachets (DPD)
HANNA InstrumentsInjection saddle for 63 mm pipe diameter half-inch thread
HANNA InstrumentsFree and Total Chlorine Portable Photometer
HANNA Instruments