Overview
The HI-8006L/C is a 500 mL bottle of 6.86 pH buffer solution in a FDA bottle with Certificate of Analysis. The pH 6.86 buffer in a 500ml bottle now has expanded stability to match pH7.01. Hanna solutions in FDA compliant bottles are opaque, light-tight bottles that meet FDA requirements.
pH6.86 is ideal for those requiring an accurate neutral reading, particularly those working in water purification plants, the food industry, aquatics, and Hydroponics, and wherever the pH is expected to be neutral. Latest Hanna portable and bench microprocessor instruments can now be calibrated with pH 6.86 and pH 7.01. Buffer solutions should be stored at 25◦C, away from direct sunlight for accurate readings.
To correctly maintain your meter/electrode, we highly recommend use of a Hanna cleaning solution, as well as a buffer, for maximum performance every time. pH7 can be used as an emergency storage solution. Hanna buffer solutions are prepared, ready-to-use, according to precise formulas and standardised in accordance with the National Institute of Standards and Technology (NIST) to ensure quality and accuracy.
All solutions show a batch number, an expiry date, and the correlation table between pH and temperature. A certificate of analysis is available on request. All bottled solutions are sealed with an air tight, tamper-proof seal to prevent any Carbon Dioxide from entering and causing a change in the pH buffer value.
Browse the Hanna complete range of solutions pH buffer solutions Standard solutions for conductivity, Total Dissolved Solids (TDS), turbidity, salinity and Ion-Selective Electrode (ISE) calibration Oxidation Reduction Potential (ORP) test and pre-treatment solutions Reference fill solutions for refillable electrodes General and specific cleaning solutions for electrodes Solutions for electrode maintenance and storage Solutions for sample preparation Solutions are available in many sizes ranging from 20ml sachets for small users to 3.78L (1 gallon) containers for large quantity usage in laboratories. For safety and traceability, all Hanna solutions are provided with a label showing the batch number and expiry date. A certificate of analysis is available on request in line with NIST standards.
*Millesimal and Technical Buffer solutions explained Designed and manufactured for those where accuracy really is vital, Millesimal buffer solutions are produced to a premium quality for customers who require a greater resolution of 0.001 for pH measurements. Accuracy can be guaranteed at +/- 0.002 @ 25◦C. To achieve the more accurate results, Millesimal Buffer solutions are available in pH1.000, pH1.679, pH2.000, pH3.000, pH4.010, pH6.000, pH6.862, pH7.010, pH8.000, pH10.010, pH11.000, pH12.000, pH12.450, pH13.000.
For those requiring a greater spectrum, as well as increased accuracy to readings, Hanna also manufacture a Technical Buffer solution range which share the accuracy of standard buffers, +/- 0.01 @ 25◦C, and feature two extra pH levels, pH1.00 and pH5.01 , along with pH4.01, pH6.86, pH7.01, and pH10.01. Both technical and Millesimal buffer solutions come with a certificate of analysis on purchase. Read More
Related Products
HANNA InstrumentsFoodcare pH 7.01 Buffer Solution - 500ml FDA Bottle
HANNA Instruments7.01 pH Buffer Calibration Solution, 500 mL FDA bottle
HANNA InstrumentsFoodcare pH 9.18 Buffer Solution - 500ml FDA Bottle
HANNA Instruments9.18 pH Buffer Calibration Solution, 500 mL FDA bottle
HANNA InstrumentsFoodcare pH 10.01 Buffer Solution - 500ml FDA Bottle
HANNA InstrumentsElectrode Cleaning Solution for Proteins, FDA 500 mL bottle
HANNA InstrumentsElectrode Cleaning Solution for Oil and Fats, FDA 500 mL bottle
HANNA Instruments