EPA Compliant Turbidity and Free & Total Chlorine Meter
HANNA Instruments HI93414-02
The instrument is based on a state-of-the-art optical system which provides accurate results by minimising stray light and colour interferences. The colorimeter portion of the meter uses a 525nm narro

Overview

The instrument is based on a state-of-the-art optical system which provides accurate results by minimising stray light and colour interferences. The colorimeter portion of the meter uses a 525nm narrow band interference filter for maintaining the proper wavelength in the measurement of free and total chlorine. Not only does this portable meter provide reliable and accurate readings on low turbidity and chlorine values, it meets and exceeds the requirements of USEPA and Standard Methods both for turbidity and colorimetric measurements.

Turbidity measurements can be made in the 0.0 to 1000 NTU range and this instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Up to 200 measurements can be stored in the internal memory and recalled at any time. CAL Check™ The HI-93414-02 features the CAL CHECK function allowing users to be able to verify the performance of the instrument at any time.

Three measurements modes The HI-93414 features three option for measurement including ratio mode for turbidity, free chlorine, and total chlorine. Turbidity measurements can be made in the 0.00 to 100 NTU (Nephelometric Turbidity Units) range, while free or total chlorine measurements can be made in the 0.00 to 5.00mg/L (ppm) range. Data transfer For further storage or analysis options, logged data can be downloaded to a Windows compatible PC using the RS232 or USB ports and the HI-92000 software.

Fast Tracker™ For advanced field applications, the HI-93414 is equipped with Fast Tracker™ Tag Identification System that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements using iButton® tags near sampling points for quick and easy readings. Each iButton® (HI-920005) tag contains a computer chip with a unique identification code encased in stainless steel.

Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water. Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.

Specifications

ParameterValue
SKUHI93414-02
Turbidity Range0.00 to 9.99 NTU 10.0 to 99.9 NTU 100 to 1000 NTU
Range SelectionAutomatic
Turbidity Resolution0.01 NTU from 0.00 to 9.99 NTU 0.1 NTU from 10.0 to 99.9 NTU 1 NTU from 100 to 1000 NTU
Turbidity Accuracy±2% of reading plus 0.02 NTU
Turbidity MethodRatio Nephelometric Method, ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Repeatability±1% of reading or 0.02 NTU, whichever is greater
Stray Light< 0.02 NTU
Light DetectorSilicon Photocell
Turbidity Standards< 0.1, 15, 100 and 750 FTU
Turbidity CalibrationTwo, three or four point calibration
Free and Total Chlorine Range0.00 to 5.00 mg/L
Free and Total Chlorine Resolution0.01 mg/L from 0.00 to 3.50mg/L 0.10 above 3.50 mg/L
Free and Total Chlorine Accuracy±0.03 mg/L ±3% of reading
Free and Total Chlorine MethodAdaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample
Free and Total Chlorine Standards1 mg/L free chlorine, 1 mg/L total chlorine
Free and Total Chlorine Calibrationone-point calibration
General specifications
Logging Memory200 records
Light Sourcetungsten filament lamp
Serial InterfaceRS232 and USB
Environmentup to 50°C (32 to 122°F); max 95% RH non-condensing
Power Supply4 x 1.5V AA alkaline batteries or AC adapter
Auto Shut-offAfter 15 minutes of non-use
Dimensions224 x 87 x 77 mm (8.8 x 3.4 x 3.0")
Weight512 g (18 oz.)
Ordering InformationHI-93414-02 (230V) is supplied with iButton® tags with tag holders (5), sample cuvettes and caps (5), calibration cuvettes for turbidity (HI-98703-11), calibration cuvettes for chlorine (HI-93414-11), silicone oil (HI-98703-58), cuvette wiping cloth, scissors, batteries, AC adapter, instrument quality certificate, instruction manual and rugged carrying case.

Accessories

  • HI-731318: HI-731318 Cuvette Cleaning Cloths x 4
  • HI-731331: HI-731331 Glass Cuvettes for Photometers and Turbidity Meters
  • HI-92000: HI-92000 Hanna Windows Software
  • HI-920005: HI-920005 I - Button with Holder (pack of 5) for use with portable meters
  • HI-920011: HI-920011 RS232 Cable
  • HI-920013: HI-920013 USB Connector
  • HI-93414-11: HI-93414-11 Calibration Set for Turbidity meters
  • HI-93701-01: HI-93701-01 Free Chlorine Reagent, DPD Method
  • HI-93701-03: HI-93701-03 Free Chlorine Reagent, DPD Method, 300 Tests
  • HI-93703-50: HI-93703-50 Cuvette Cleaning Solution, 230ml
  • HI-93711-01: HI-93711-01 Total Chlorine Reagent, DPD Method, 100 tests
  • HI-93711-03: HI-93711-03 Total Chlorine Reagent, DPD Method (300 tests)