HANNA Instruments HI93703-0
0 FTU turbidity calibration standard

Product Overview

HI93703-0 0 FTU Turbidity Calibration Standard provides a simple solution for calibrating and verifying the HI93703 turbidity meter with a range of 0 to 1000 FTU. Hanna turbidity calibration standards are made from NIST-traceable primary standard reference materials and come with a certificate of analysis. The certificate of analysis provides the lot number, reference value, and expiration date for traceability when certifying an appropriate turbidity meter.

  • Certificate of analysis provided

  • 0 FTU standard value

  • Reusable with long shelf life and good stability

  • Turbidity meters compliant with the HI93703 ISO standard are designed for routine standardization using known light-scattering standards. Like all analytical standards or reference materials, turbidity standards should be able to perform the following: provide traceability, demonstrate the accuracy of results, calibrate equipment and methods, monitor user performance, verify tests, and facilitate comparability. Standardization ensures that, when correct procedures are followed, the same analysis performed on the same material will produce mutually consistent results regardless of when it is performed.

  • Hanna turbidity standards are prepared from AMCO AEPA-1 material, which is known for highly stable and reliable standardization. AMCO AEPA-1 turbidity standards are stable suspensions of cross-linked styrene-divinylbenzene copolymer microbeads in ultrapure water. These beads are chemically inert and maintain chemical equilibrium in aqueous media regardless of concentration. The particle size, uniform shape, and refractive index make these spheres ideal for characterizing light absorption and scattering at 90° behavior in the UV-VIS range. In addition, the spherical shape and size of the beads help prevent accumulation or settling of the standard material. For these reasons, AMCO AEPA-1 standards are very stable.

  • This standard is prepared and bottled in a cleanroom facility. It has been tested and verified for accuracy and stability and has been shown to be free of any toxic chemicals or compounds. All prepared standards are compared with formazin turbidity standard solutions. The values obtained and the analysis date are reported on the provided certificate of analysis.

  • HI93703-0 is a high-quality turbidity calibration standard that allows users to verify and calibrate the HI93703 turbidity meter with an FTU range of 0 to 1000. HI93703-0 includes a standard solution with an expected reading of 0 FTU. Calibration standards are produced in our state-of-the-art manufacturing facility using NIST-traceable reference materials in a temperature-controlled environment.

  • Certificate of analysis provided

  • Lot number

  • Expiration date

  • Standard value

  • NIST-traceable reference meter

  • Storage container provided

  • Light-proof

  • Protects against accidental breakage

  • HI93703-0 turbidity calibration standard is specifically formulated for the HI93703 turbidity meter. The calibration process is simple and quick.

SKU HI93703-0
Product Name 0 FTU Turbidity Calibration Standard - HI93703-0
Quote Required Yes
Package Standard solution
Quantity 1 bottle
Size 30 mL
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.