Overview
The HI-93715-03 are high quality, pre-measured reagents that allow users to achieve fast and accurate colorimetric measurements. This reagent provides enough to do 300 tests. Range: 0.00 to 10.00 mg/L Benefits highlighted: Pre-made reagents for ease of use Prepared with high purity chemicals Marked with expiry date and lot number for traceability These reagents follow the Nessler Method in which the reaction between ammonia and the reagent causes a colour change in the sample.
The intensity of colour is determined by a compatible photometer. The concentration, based upon the meter in use, will be displayed in mg/L (ppm) as ammonia (NH 3 ) or ammonia nitrogen (NH 3 -N). These reagents are designed to be used with samples that have an expected range of 0.00 to 9.99 mg/L ammonia.
Please download the Safety Datasheet(s) which provide more detail on the reagents before use; click on the link in the “safety data sheets” paragraph below. The HI-93715-03 Ammonia, medium range reagent is suitable for use with the HI-96715 portable photometer, the HI-83200-02 and HI-83099-02 multi-parameter bench photometer, and other meters where specified. About Ammonia Present naturally in surface and waste waters, ammonia mainly results from the deamination of organic nitrogen-containing compounds and hydrolysis of urea.
Ammonia may also be present from water treatment processes that utilise chloramines for disinfection, where ammonia is added to the water to react with chlorine. Ammonia is less likely to appear in groundwater due to adsorption to soil particles. Safety Data Sheets Access safety data sheets online here.
When using any form of chemical, it is important you download the relevant safety datasheet and make yourself aware of any precautions you should take when handling the chemical. You can access our library of safety datasheets and download a copy by following the link below. Please note that the '-' in HI- products should be removed from all searches to find the correct information.
click here
Specifications
| Parameter | Value |
|---|---|
| SKU | HI93715-03 |
| Package | dropper bottles ‘A’ and ‘B’ |
| Quantity | 300 tests |
| Method | ASTM Manual of Water and Environmental Technology, D1426-93, Nessler Method. The reaction between ammonia and the reagents causes a yellow tint in the sample. |
Related Products
HANNA Instruments1382mg/L (ppm) TDS Calibration Solution, 230mL bottle
HANNA Instruments111 800uS/cm Conductivity Solution, 230 mL bottle
HANNA Instruments5000µS/cm Conductivity Solution, 230mL bottle
HANNA InstrumentsPotassium Iodide Powder Packets, 100 Packets
HANNA InstrumentsCombination Buffer Kit 10.01 & 7.01 pH 5 x 5 Sachets & Certificate of Analysis
HANNA InstrumentsCombination Buffer Kit 10.01 & 7.01 pH 5 x 5 20ml Sachets
HANNA InstrumentsCombination pH/TDS Buffer Kit 1500 ppm & 7.01 pH
HANNA Instruments