Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

AV88EB0C2

AV88EB0C2
Orion acid-base concentration transmitter AV88EB0C2
Other AV88EB0C2
4~20 mA output Power supply: 230V Operating temperature: -10~70°C Storage temperature: -15~75°C

Product Overview

The Thermo Scientific Orion 2105AB acid-base concentration meter is used for detection in power plant pure water analysis systems.

Product details:

Applications:

Wastewater discharge (purified water), complete water treatment systems, food/beverage process, pharmaceutical process water, power system pure water monitoring.

Features:

1. Wide measuring range: 0%-10% (acid-base concentration), 0-2,000,000μS/cm (conductivity)

2. Customizable and addable standard curves

3. High-precision temperature compensation

4. Fouling resistant

5. 0-20mA or 4-20mA analog output

AV88EB0C2
Technical parameters
Measuring range 0%-10% (acid-base concentration), 0-2,000,000μS/cm (conductivity)
Resolution 5 significant digits
Accuracy 0.1% of reading
Response time 30s to reach 90%
Sample requirements Temperature: -5℃-75℃
Pressure: max. 85PSIG
Flow rate: max. 3.0m/s
Meter installation 1/4"DIN or 1/2"DIN panel mount or wall mount
Electrode 1 inch NPT or flange
1 inch NPT or flange PG11, PG16
Power supply 90-240VAC; 50/60Hz
 
Model parameters
Order No. AV88EB0C2
Name  Controller AV88 universal type
Brand Thermo Scientific Orion 
Power supply 230V
Storage temperature -15~75°C
Display LCD
Analog output signal 4~20 mA
Operating temperature -10~70°C
 
Accessories list:
2105AB acid-base concentration meter
AV88 controller AV88EB0C2
Acid-base concentration meter probe ST230C
Municipal Wastewater Treatment

Municipal Wastewater Treatment · VEGA — Stock Configuration Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on VEGA and the core task is covering level and pressure measurement with VEGA instruments.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So VEGA cannot be specified generically — it calls for choosing radar or pressure families by dust, vapour and corrosion.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves choosing radar or pressure families by dust, vapour and corrosion, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is friendly commissioning software that shortens start-up.

Food & Beverage

Food & Beverage · VEGA — Stock Configuration Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted VEGA properly configured on the existing plant, with the aim of covering level and pressure measurement with VEGA instruments.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the VEGA configuration has to involve choosing radar or pressure families by dust, vapour and corrosion.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant choosing radar or pressure families by dust, vapour and corrosion, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is friendly commissioning software that shortens start-up, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · VEGA — Stock Configuration Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was covering level and pressure measurement with VEGA instruments.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing radar or pressure families by dust, vapour and corrosion.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around choosing radar or pressure families by dust, vapour and corrosion, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — friendly commissioning software that shortens start-up, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · VEGA — Stock Configuration Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from VEGA, focusing on covering level and pressure measurement with VEGA instruments.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The VEGA specification must therefore cover choosing radar or pressure families by dust, vapour and corrosion.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on choosing radar or pressure families by dust, vapour and corrosion, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — friendly commissioning software that shortens start-up, with confidence in this measuring point improving markedly.