VEGAPULS 63

VEGAPULS 63
VEGAPULS 63
VEGA PS63
Configurable Models 10 models
VEGAPULS 63 is a radar sensor for continuous level measurement of aggressive liquids or for applications with hygiene requirements. It is suitable for use in storage tanks, process vessels, dosing vessels and reactors. The plastic-encapsulated antenna system of VEGAPULS 63 protects it against contamination and ensures maintenance-free long-term operation. Front-flush with the
Compare

Measurement

Measuring range up to 35 m (114.8 ft)
Deviation ±2 mm

Process conditions

Process fitting Hygienic fitting, pipe thread fitting, flange from DN 50, 2"
Process pressure -1 … +16 bar/-100 … +1600 kPa (-14.5 … +232 psig)
Process temperature -196 … +200 ℃ (-321 … +392 ℉)
Ambient, storage and transport temperature -40 … +80 ℃ (-40 … +176 ℉)

Electrical & communication

Operating voltage 9 … 32 V DC

Application area

The VEGAPULS 63 is a radar sensor for continuous level measure­ment of aggressive liquids or with hygienic requirements. It is suitablefor applications in storage tanks, process vessels, dosing vessels andreactors. The encapsulated antenna system of VEGAPULS 63 protectsagainst pollution and ensures a maintenance-free permanent operation.The front-flush mounting ensures an optimum cleanability even withhigh hygienic requirements.

Your benefit

  • Maintenance-free operation thanks to non-contact measuring princi­
  • ple
  • High plant availability, because wear and maintenance free
  • Exact measuring results independent of process conditions

Function

Extremely short microwave pulses are emitted by the antenna system inthe direction of the measured product, reflected by the product surfaceand received back again by the antenna system. The time from emis­sion to reception of the signals is proportional to the level in the vessel.A special time stretching procedure allows reliable and precise meas­urement of the extremely short signal running times.

10 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Flow Meter Accessories — Stock Configuration Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was completing flow meters with electrodes, liners, seals and mounting kits.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means matching electrode material, liner type and pressure rating against the original model.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around matching electrode material, liner type and pressure rating against the original model, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — restoring metering quickly instead of replacing whole instruments, with routine maintenance falling noticeably.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Analyzer Accessories — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Analyzer Accessories properly configured on the existing plant, with the aim of supplying electrodes, flow cells, tubing and calibration consumables for analysers.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Analyzer Accessories configuration has to involve selected per measuring principle and range, never mixing principles.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected per measuring principle and range, never mixing principles, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is restoring original calibration intervals and data comparability, and the readings are now used for process tuning.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Online Analyzer Accessories — Stock Configuration Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on Online Analyzer Accessories and the core task is completing online analysers with sampling, conditioning and flow-path parts.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So Online Analyzer Accessories cannot be specified generically — it calls for sizing conditioning stages to sample temperature, pressure and solids.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves sizing conditioning stages to sample temperature, pressure and solids, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is better sample representativeness and higher online availability.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Ultrasonic level meter — Stock Configuration Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is Ultrasonic level meter; the focus is non-contact continuous level measurement in tanks and sumps.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with checking how vapour, foam and agitation affect the acoustic echo.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on checking how vapour, foam and agitation affect the acoustic echo, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means no fouling because nothing touches the medium, so maintenance stays low, which cut the workload on the site maintenance team.