Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

106395 NH 500/2

106395 NH 500/2

NH 500/2

WTW 106395
Ammonia gas-sensitive combination electrode with plug head, 0.02 to 900 mg/l, requires ionic strength adapter MZ/NH3/CN standard solution ES/NH4. 3 exchange heads and 50 ml electrolyte solution.

Ion-selective electrodes

Potassium, Fluoride, Aluminium, Phosphate, Lithium, Ammonium, Copper, Cyanide, Chloride, Sodium, Calcium, Magensium, Silver, Nitrate, Bromide

Ion-selective and gas-sensitive electrodes are used for measuring the dissolved concentration of specific ions or gases in water. Similar to the pH electrode, the membrane interacts with the dissolved ions and delivers a concentration-dependent voltage signal  that is converted to the corresponding measurement result.

Highlights:

  • Space-saving through integrated reference electrode
  • broad selection of applications including ammonium measurement

  • Slim and space-saving design with 12 mm shaft diameter

Variants
Art.-Nr. Name Description Connection
106395 NH 500/2 Ammonium-selective electrode S7-Plug head, without cable
106649 Na 800/S7 Sodium-selective electrode S7-Plug head, without cable
106651 Ag/S 800 DIN Silver-/Sulphide-selective electrode 1 m DIN cable
106653 Br 800 DIN Bromide-selective electrode 1 m DIN cable
106655 Ca 800 DIN Calcium-/Magnesium-selective electrode 1 m DIN cable
106656 Ca 800/AT Exchange head for Ca 800 -
106661 Cl 800 DIN Chloride-selective electrode 1 m DIN cable
106663 CN 800 DIN Cyanide-selective electrode 1 m DIN cable
106665 Cu 800 DIN Copper-/Nickel-selective electrode 1 m DIN cable
106666 F 800 BNC Fluoride-/Aluminium-/
Phosphate-/Lithium-selective electrode
1 m BNC cable
106667 F 800 DIN Fluoride-/Aluminium-/
Phosphate-/Lithium-selective electrode
1 m DIN cable
106671 K 800 DIN Potassium-selective electrode 1 m DIN cable
106672 K 800/AT Exchange head for K 800 -
106675 NO 800 DIN Nitrate-selective electrode 1 m DIN cable
  • Electrode NH 500/2 Na 800/S7 Ag/S 800 DIN Br 800 DIN
    Art.-No. 106395 106649 106651 106653
    Ions Ammonium Sodium Silver-/Sulphide Bromide
    Measuring range 10-6 ... 5 · 10-2 mol/l NH4+
    0,02 ... 900 mg/l NH4+
    10-6 ... 1 mol/l Na+
    0,01...23000 mg/l Na+
    Ag: 0,01 ... 108.000 mg/l
    Sulfid: 0,003 bis 32.000 mg/l
    0,4 ... 79000 mg/l Br-
    Reference electrolyte - 3 mol/l KCl - -
    Diaphragm - Platin - -
    pH range   8 ... 11 2 ... 12 1 ... 12
    Temperature range 0 ... 50 °C -10 ... +80 °C 0 ... 80 °C 0 ... 80 °C
    Membrane resistance   < 500 MΩ < 1 MΩ < 0,1 MΩ
    Shaft length 120 mm 120 mm 120 mm 120 mm
    Shaft diameter 12 mm 12 mm 12 mm 12 mm
    Immersion depth min. 5 mm
    max. 50 mm
    min. 20 mm
    max. 100 mm
       
    Needs: Ionic strength-adjusting
    solution MZ/NH3/CN,
    Standard solution ES/NH4
    Ionic strength-adjusting
    solution ISA/Na,
    Standard solution ES/Na,
    Cable AS/DIN or AS/BNC
    Bridge electrolyte ELY/BR/503,
    Ionic strength-adjusting solution ISA/FK (Ag-Ionen) or according
    to the operating
    instructions for sulphide
    measurement
    Bridge electrolyte ELY/BR/503,
    Ionic strength-adjusting solution ISA/FK,
    Standard solution ES/Br
    Addit.
    scope of delivery
    3 exchange heads, 50 ml electrolyte solution - - Electrolyte
    Connection S7-plug head, without cable S7-plug head, without cable 1 m DIN cable 1 m DIN cable
     
    Elektrode Ca 800 DIN Cl 800 DIN CN 800 DIN Cu 800 DIN
    Art.-No. 106655 106661 106663 106665
    Ions Calcium Chloride Cyanide Copper/Nickel
    Measuring range 0,02 ... 40.000 mg/l Ca2+ 2 ... 35.000 mg/l Cl- 0,2 ... 260 mg/l CN- (empfohlen 0,2 ... 25 mg/l CN- )
    8 x 10-6 ... 1 x 10-2 mol/l CN-
    (empfohlen 8 x 10-6 ... 1 x 10-3 mol/l CN- )
    6 x 10-4 ... 6.350 mg/l Cu2+
    Reference electrolyte - - - -
    Diaphragm - - - -
    pH range 2,5 ... 11 2 ... 12 0 ... 14 2 ... 6
    Temperature range 0 ... 40 °C 0 ... 80 °C 0 ... 80 °C 0 ... 80 °C
    Membrane resistance 1 bis 4 MΩ < 1 MΩ < 30 MΩ < 1 MΩ
    Shaft length 120 mm 120 mm 120 mm 120 mm
    Shaft diameter 12 mm 12 mm 12 mm 12 mm
    Immersion depth        
    Needs: Bridge electrolyte ELY/BR/503,
    Ionic strength-adjusting solution ISA/Ca,
    Standard solution ES/Ca
    Bridge electrolyte ELY/BR/503,
    Ionic strength-adjusting solution ISA/FK,
    Standard solution ES/Cl
    Bridge electrolyte ELY/BR/503,
    Ionic strength-adjusting solution MZ/NH3/CN
    Bridge electrolyte ELY/BR/503,
    Ionic strength-adjusting solution ISA/FK
    Standard solution ES/Cu
    Addit.
    scope of delivery
    Electrolyte and exchange heads Electrolyte Electrolyte Electrolyte
    Connection 1 m DIN cable 1 m DIN cable 1 m DIN cable 1 m DIN cable
     
    Elektrode F 800 BNC F 800 DIN K 800 DIN NO 800 DIN
    Art.-No. 106666 106667 106671 106675
    Ions Fluoride/Aluminium/
    Phosphate/Lithium
    Potassium Nitrate
    Measuring range 0,02 mg/l F- (10-6 mol/l) bis Sättigung 0,04 ... 39.000 mg/l K+ 0,4 ... 62.000 mg/l NO3-
    Reference electrolyte - - -
    Diaphragm - - -
    pH range 5 ... 7 2 ... 12 2,5 ... 11
    Temperature range 0 ... 80 °C 0 ... 40 °C 0 ... 40 °C
    Membrane resistance 0,15 ... 0,2 MΩ < 50 MΩ 1 bis 5 MΩ
    Shaft length 120 mm 120 mm 120 mm
    Shaft diameter 12 mm 12 mm 12 mm
    Immersion depth      
    Needs: Bridge electrolyte ELY/BR/503,
    Ionic strength-adjusting solution TISAB,
    Standard solution ES/F
    Bridge electrolyte ELY/BR/503/K,
    Ionic strength-adjusting solution ISA/K,
    Standard solution ES/K
    Bridge electrolyte ELY/BR/503/N,
    Ionic strength-adjusting solution TISAB/NO3,
    Standard solution ES/NO3
    Addit.
    scope of delivery
    Electrolyte and exchange heads Electrolyte and exchange heads Electrolyte and exchange heads
    Connection 1 m BNC cable 1 m DIN cable 1 m DIN cable 1 m DIN cable
Municipal Wastewater Treatment

Municipal Wastewater Treatment · WTW — Stock Configuration Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · WTW — Stock Configuration Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · WTW — Stock Configuration Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.

Power & Energy

Power & Energy · WTW — Stock Configuration Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.