VARiON®Plus N comp SET NO3
-
Digital ISE sensor for NH4 and NO3, connectable to the IQ SENSOR NET
-
- Ammonium and nitrate measurement directly in the process
- Simultaneous compensation of potassium, chloride
- No sampling, reagent-free
- Calibration free, long-term stability
-
Ion selective measurement of ammonium and nitrate free of reagents with automatic compensation of potassium/chloride with the VARiON® Plus 700 IQ:
These especially stable electrodes ensure long operation times and a simple cleaning method. To measure, simply install the respective electrode into the IQ SENSOR NET, everything else will take place automatically. In the measured value display, the values that have already been compensated, are displayed, you can select potassium or chloride output. These values also stand for the signal output per 0/4-20 mA output or digital output (Profibus, Modbus RTU, Ethernet/IP, Modbus TCP) is directly available.
New: Measurement of media with high ammonium load
When thickening or dehydrating wastewater treatment sludge, the so-called centrate water is generated. This water has an especially high amonium content. The centrate water is not drained but rerouted into the wastewater circuit of the system or directly broken down into elementary nitrogen (deammonification). In both cases, the determination of the NH4 freight is very important for an optimal process run. High NH4 concentrations of up to 2000 mg/l can now be determined directly in the medium by means of the Varion®Plus 700 IQ, in centrate water as well as in process waters!
|
Ammonium Measurement |
Nitrate Measurement |
|
|
Measuring method |
Electrochemical |
|
|
Maximum Configuration |
Common reference electrode, two measuring electrodes, one compensation electrode |
|
|
Integrable Electrodes: |
||
|
Reference Electrode |
VARiON®Plus Ref |
|
|
Measuring Electrode |
VARiON®Plus NH4 |
VARiON®Plus NO3 |
|
Compensation Electrode |
VARiON®Plus K |
VARiON®Plus Cl |
|
Measuring range/ Resolution |
NH4-N: 1 ... 2,000 mg/l / 1 mg/l; NH4+: 1 ... 2,580 mg/l / 1 mg/l; |
NO3-N: 1 … 1,000 mg/l / 1 mg/l; NO3-: 5 … 4500 mg/l / 1 mg/l; |
|
Compensation Ranges |
K+: 0.1 ... 1,000 mg/l / 0.1 mg/l |
Cl-: 0.1 ... 1,000 mg/l / 0.1 mg/l |
|
Measuring Accuracy in laboratory standard solutions |
± 5 % of measured value ± 0.2 mg/l in standard solutions |
|
|
Calibration Procedures |
Matrix adjustment against any reference value, 2-point-calibration possible with multiple standard solution |
|
|
Working Life (typically) |
Reference electrode: 18 months, |
|
|
Temperature Measurement and Compensation |
Integrated NTC thermistor, Range 32 °F … 104 °F (0 °C … +40 °C), Accuracy ±0.5 K, Resolution 0.1 K, t95 < 20 s |
|
|
Pressure Resistance |
Maximum 0.2 bar (incl. SACIQ sensor connection cable, with installed electrodes) |
|
|
Ambient Conditions |
Operating temperature: 32 °F … 104 °F (0 °C … +40 °C), storing temperature: 32 °F … 104 °F (0 °C … +40 °C) |
|
|
Electrical connections |
2-wire shield cable with quick fastener to sensor |
|
|
Electromagnetic |
EN 61326, Class B, FCC Class A; |
|
|
Certifications |
CE |
|
|
Mechanical |
Sensor body: V4A stainless steel 1.4571 Protective cup: POM |
|
|
Weight |
Approx. 1.48 lb (670 g, without electrode, without sensor connection cable) |
|
|
Warranty |
VARiON®Plus 700 IQ: 2 years |
|
Case Studies
Municipal Wastewater Treatment · WTW — Stock Configuration Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.
Food & Beverage · WTW — Stock Configuration Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.
Solution
The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.
Chemical & Pharmaceutical · WTW — Stock Configuration Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.
Power & Energy · WTW — Stock Configuration Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.