Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

1CA301 inoLab® Cond 7310 SET 1

1CA301 inoLab® Cond 7310 SET 1

inoLab® Cond 7310 SET 1

WTW 1CA301
Precise and convenient conductivity meter, menu controlled, for measurements/documentation according GLP/AQA. For AC and battery operation. Set including conductivity cell. Meter with universal power supply, stand and operation manual. Including 4-electrode graphite conductivity cell TetraCon® 325, 0.01 mol/l KCl conductivity standard, software and USB cable.

inoLab® Cond 7310 Analog Lab Conductivity Benchtop Meter

inoLab® Cond 7310: Precise and high performance laboratory conductivity meter with GLP supportung functions for documentation measuring results

Variants
Art.-No. Name Description
1CA300 inoLab® Cond 7310 Single unit with universal power supply, stand, manual, CD-ROM with software and USB cable
1CA300P inoLab® Cond 7310P Single unit with built-in printer, universal power supply, stand, manual, CD-ROM with software and USB cable
1CA301 inoLab® Cond 7310 SET 1 Single unit with 4-Pol TetraCon® 325, 0,01 mol/l KCl, universal power supply, stand, manual, CD-ROM with software and USB cable


Highlights:

  • Convenient and safe operation via plain text menus
  • Documentation of all data via USB interface or optional built-in printer - fast and error-free
  • Suitable for measurements according pharmacopeia
  • Repeatable measuring results by active, automatic AutoRead function with automatic recognition of stable values
  • The sensor symbol informs about the status of the electrode
  • Graphic display with plain text menus for the convenient and safe operation

The inoLab® Cond 7310 is highly suitable for all conductivity precision measurements connected with automatic documentation according to GLP/AQA in quality labs in all industries. It works with all modern WTW conductivity measuring cells to cover all applications. For the documentation, the serial number of the used sensor can be entered. Upon request, the measured values can be put out via the optional built-in printer.

  • Parameter Conductivity/Salinity/spec. resistivity, TDS
    Conductivity 0.001 µS/cm ... 1000 mS
    spezischer Widerstand 0.00 ... 199 MOhm cm
    Salinity 0.0 ..70.0
    TDS 0 ... 199.9 g/l
    Temperature -5.0 ... 105 °C
    Resolution Conductivity 0.1 µS/cm 
    Salinity 0.1
    Accuracy Temperature +/- 1 digit 0.1 K
    Accuracy Messwerte +/- 1 digit +/- 0.5 %
Municipal Wastewater Treatment

Municipal Wastewater Treatment · WTW — Stock Configuration Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · WTW — Stock Configuration Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · WTW — Stock Configuration Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.

Power & Energy

Power & Energy · WTW — Stock Configuration Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.