inoLab® Multi 9620 IDS
inoLab® Multi 9620 IDS - Digital Multiparameter Lab Benchtop Meter
inoLab® Multi 9620 IDS: Digital high performance multi-parameter device with two inputs for pH, ISE, conductivity and dissolved oxygen and comprehensive GLP functions
| Variants | ||||
| Art.-No. | Name | Description | ||
| 1FD560 | inoLab® Multi 9620 IDS | Single unit with universal power supply, stand, manual, CD-ROM with software, USB cable | ||
| 1FD56C | inoLab® Multi 9620 SET C | Single unit with SenTix® 980, TetraCon® 925, QSC-Kit (EVE required), Buffer 4, 7 und 10.01, 3 mol/l KCl, 0,01 mol/l KCl, universal power supply, stand, manual, CD-ROM with software, USB cable | ||
Highlights:
- Measures pH, Redox, ISE, dissolved oxygen and conductivity
- Wireless ready
- Digital sensor detection
- Simultaneous measurement with two independent measuring channels
- Fatigue proof reading on brilliant color display
Modern high-performance multi-parameter meter with two galvanically isolated measuring channels pH/mV, ISE (including incremental methods), conductivity and oxygen measurement. With a large 16:9 color graphic display under a hygienic glass shield and antibacterial keyboard for use, even in critical areas. Use the new wireless modules together with the new IDS plug head sensors, be independent from cables and measure i.e. conveniently under laboratory hoods or laminar flow benches. The massive zinc diecasting lower housing adds safety against interference and ensure a safe, stable stand on the lab bench.
Two USB interfaces to communicate with the computer, printer or USB memory stick allow the transfer of all data. An activatable user administration expands the automatic GLP documentation by additional safety and traceability.
Integratable adapter available for conventional pH/ORP/ISE electrodes. The scope of delivery includes the MultiLab® Importer to capture data via Excel® as well as the MultiLab® User (user administration).
-
Parameter pH, mV, ISE, saturation, concentration, partial pressure, conductivity, spec. resistance, salinity, TDS, temperature Universal measuring channels 2 Measuring range Depends on the IDS sensor used Display LCD color graphic CMC/QSC Yes/Yes Data memory manual 500/10000 automatic Analog pH/ORP/ISE sensors ADA 94 pH/IDS DIN or ADA 94 pH/IDS BNC Logger manual/time-controlled Interface USB A/Mini USB-B Printer Three pre-installed drivers (description see Operating Instructions) Power supply Universal power supply 100 to 240 V, 50/60 Hz
Case Studies
Municipal Wastewater Treatment · WTW — Stock Configuration Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.
Food & Beverage · WTW — Stock Configuration Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.
Solution
The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.
Chemical & Pharmaceutical · WTW — Stock Configuration Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.
Power & Energy · WTW — Stock Configuration Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.