photoLab 7100 VIS
photoLab® 7100 VIS von 320 – 1100 nm offers the unique combination of systematic and spectral analysis in this class of spectrophotometers: Multi-purpose meters for the use from water analysis and wine industry to research and education. Well-proven and liked is the user guidance even for complex tasks. The brilliant HD color display supports menu-guided operations additionally with colored information and messages.
- Barcode support and automatic cuvette recognition
- Standard methods such as UVT, SAC, coloration or chlorophyll
- Multi-level AQA
- Comprehensive programming opportunities
Routine at it’s best
photoLab® 7100 VIS supports fast and affordable routine analysis via barcoded test kits for round and rectangular cuvettes. More than 250 methods are available for waste/drinking water, food & beverage industry as well as production, environmental monitoring or fish farming:
- Easy to use: place cuvette, read measurement value
- More than 250 test programs for water analysis, galvanics and general lab analytics
- Cell and reagent test kits with barcode for automatic program selection
- Automatic cuvette and measurement range detection for rectangular cuvettes
- Top reliability due to menu guided comprehensive Analytical Quality Assurance - AQA
- Measurement “Light” on the road with car battery use
- USB and Ethernet-connections for easy update, print to PDF or printer, storage and data export
From Food to Science
Special procedures for environmental and food parameters such as chlorophyll can be executed handy and clearly arranged due to an excellent menu guidance:
- Programmed multistep- and multiwavelength methods
- Comprehensive programming options for user defined requirements
- Spectra and Kinetics measurements
- Training of basics and modern photometry in education
photoLab® color: Color measurement instead of color perception
Color determination by means of photometric measurement has increased the accuracy and comparability in general compared to subjective perception of visual color measurement procedures. Color measurement is essential for many applications: from water analysis to food & beverage and quality control in production processes. Color values being a quality factor mostly lie within a certain user-specific tolerance range.
With photoLab® 7000 / 6000 Series and the optional PC-software photoLab® color common measurement procedures can be performed in a handy and neatly arranged way.
photoLab® Data spectral
The optional photoLab® Data spectral offers a GLP-compliant and convenient PC-interface to export, store and transfer data.
| Wavelength Range | 320 - 1100 nm |
| Optics | Monochromator with Grating and step motor / reference beam |
| Lamp | Wolfram-Halogen |
| Display | Farbdisplay 7" backlit |
| Bandwidth | 4 nm |
| Measurement | Concentration, Absorbance, % Transmission, Kinetics and Spectra in Abs or %Transmission, Multiwavelengths and multistep readings |
| Scan speed | 700-2000 nm/min, Scans in 1, 2, 5, 10 nm steps of wavelength range |
| Wavelength accuracy/reproduceability | ± 1 nm / < 0,5 nm |
| Photometric accuracy/reproduceability | - 0,003 E for E < 0,600; 0,5% of values for 0,600 < E < 2,000 |
| Photometric linearity | < 1 % for A ≤ 2.000 in the range 340 ... 900 nm |
| Straylight | < 0,1 %T at 220 nm with NaI, < 0.05 % transmission at 340 and 408 nm with cut-off filter |
| Barcode | Automatic method recognition including measurement range for all cuvette |
| Cuvette | 16 mm round, rectangular 10 mm, 20 mm, 50 mm with automatic cell detection for automatic measurement range setting |
| Data storage | 5000 meausrement values, spectra and kinetics approx. 40 MB => 500 spectra (300-900 nm) and 400 kinetics with 150 measurement values, |
| Methods and Profiles | > 250 pre-programmed methods, 1000 user-defined methods, profiles for kinetics and spectra, comprehensive programming options |
| Interface / Update | 1 USB-A, 1 USB-B, 1 Ethernet / Update via Internet and USB-Stick |
| IP Class | IP 30 including drainage in optical compartment |
| Power Supply | Universal power supply, optional supply via standard adaptor cable for car batteries |
| Temperature Range | Operation: +10°C bis +35°C, Storage: -25°C bis +65°C |
| Weight / Dimensions | approx. 4,5 kg / 404 x 197 x 314 (BxHxT) |
| Accessories | PC software photoLab® Data spectral+photoLab® color, field case, checking tools for AQA |
Case Studies
Municipal Wastewater Treatment · WTW — Stock Configuration Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.
Food & Beverage · WTW — Stock Configuration Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.
Solution
The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.
Chemical & Pharmaceutical · WTW — Stock Configuration Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.
Power & Energy · WTW — Stock Configuration Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.