Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

2BA100 Oxi 3205

2BA100 Oxi 3205

Oxi 3205

WTW 2BA100
Easy-to-operate, robust DO meter with backlit LCD graphic display, for routine measurement, single instrument. Single instrument in a case including short instruction manual, CD-ROM and batteries.

ProfiLine Oxi 3205 analog portable meter

ProfiLine Oxi 3205: Professional dissolved oxygen pocket meter with mini USB interface for mobile applications or routine measurements with documentation

Variants
Art.-No. Name Description
2BA100 Oxi 3205 Single unit in field case with manual, CD-ROM, batteries
2BA101 Oxi 3205 Set 1 Single unit in field case with galvanic DO sensor CellOX® 325 with cleaning solution, electrolyte, exchange membrane heads, stand, beaker, manual, CD-ROM, batteries


Highlights:

  • Easy-to-use with simplified keypad
  • Backlit graphic display for measurements in all lighting conditions
  • For alle galvanic D.O. sensor except StirrOx
  • Robust and waterproof (IP 67)

Dissolved oxygen measurement - really simple: The Oxi 3205 is an easy to use, robust and waterproof portable meter for the measurement of dissolved oxygen, i.e. in surface waters, in wastewater treatment plants and in fish farming applications. It is suitable for galvanic oxygen sensors of the CellOx® and DurOx® series; the adjustable salinity compensates for the salt content when measuring sea water and allows correct measured values. The results can be displayed either as saturation or concentration.

  • ProfiLine Oxi 3205 Oxi 3205 Set 1
    Art.-No. 2BA100 2BA101
    Parameters Concentration/Saturation/Partial pressure/Temperature
    Concentration 0.00 … 90 mg/l
    Saturation 0.0 ... 600 %
    Partial pressure 0.0 ... 1250 hPa
    Temperature -5.0 ... 50.0 °C
    Resolution Concentration 0.01 mg/l
    Resolution Saturation 0.1 %
    Resolution Partial pressure 0.1 hPa
    Protection class IP 67
    Betriebstemperatur -10 °C ... + 55 °C
    Content Single unit in field case with manual, CD-ROM, batteries Single unit in field case with galvanic DO sensor CellOX® 325 with cleaning solution, electrolyte, exchange membrane heads, stand, beaker, manual, CD-ROM, batteries
Municipal Wastewater Treatment

Municipal Wastewater Treatment · WTW — Stock Configuration Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · WTW — Stock Configuration Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · WTW — Stock Configuration Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.

Power & Energy

Power & Energy · WTW — Stock Configuration Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.