WTW 2EA312
Professional pH/conductivity meter with 2 inputs (DIN, 8-pin socket), backlit graphic display, for mobile applications with data logger and USB interface. Portable meter, including SenTix®41, TetraCon®325, buffer solutions STP 4 and STP 7, conductivity standard 0.01 mol/L KCl, operating manual, stand, beakers, CD-ROM, USB driver software, batteries, cable.

ProfiLine pH/Cond 3320 analog portable meter

ProfiLine pH/Cond 3320: Universal multi-parameter portable meter with two inputs for pH, mV, ISE and conductivity measurements for demanding applications

Variants
Art.-No. Name Description
2EA310 pH Cond 3320 Single unit in field case with buffers STP 4 und STP 7, 0,01 mol/l KCl, manual, CD-ROM and batteries, driver software for USB, cable
2EA312 pH Cond 3320 Set 2 Single unit in field case with SenTix® 41, TetraCon® 325, buffers STP 4 and STP 7, 0,01 mol/l KCl. manual, stand, beaker, CD-ROM, driver software for USB, batteries, cable


Highlights:

  • Two inputs for the simultaneous measurement of pH/mV/ISE and conductivity
  • Backlit graphic display for the parallel display of the measured values
  • Perfect for monitoring process applications

The pH/Cond 3320 has a robust, waterproof housing (IP67) and is equipped with a memory as well as a data logger with an adjustable interval between 1 s and 60 minutes. All entries contain GLP-supporting data, like the date, time and ID number. The modern, waterproof USB interface is used for easy and quick data transfers. It can be used almost anywhere - in process chemistry, Life Science, food and beverage industry all the way to the pharmaceutical industry (measurement of pH and conductivity according to pharmacopeia).

ProfiLine pH Cond 3320 pH Cond 3320 Set 2
Art.-No. 2EA310 2EA312
Parameters pH, Conductivity/Salinity/spec. Resistance, TDS
Measuring range pH -2,000 … 19,999
Accuracy pH +/- 1 digit +/- 0,005/ +/-0,01/0,1
Measuring range Temperature - 5,0 ... + 105,0 °C
Accuracy Temperature +/- 1 digit +/-0,1 K
Measuring range mV -1250,0 ...+1250,0 / -2500...+2500 mV
Accuracy mV +/- 1 digit +/- 0,3 mV/ +/- 1 mV
Measuring range SAL 0,0 ... 70,0
Measuring range Cond. 0,001 µS/cm ... 1000 mS
Resolution conductivity bis 0,001 µS/cm
Accuracy Measurements +/- 1 digit +/- 0,5 %
TDS 0 ... 199,9 g/l
specific resistance 1,000 ... 1999 Ohm*cm
Operating temperature -10 °C ... + 55 °C
Protection class IP 67
Data storage Manuell: 200, Automatisch: 5.000
Content Single unit in field case with buffers STP 4 und STP 7, 0,01 mol/l KCl, manual, CD-ROM and batteries, driver software for USB, cable Single unit in field case with SenTix® 41, TetraCon® 325, buffers STP 4 and STP 7, 0,01 mol/l KCl. manual, stand, beaker, CD-ROM, driver software for USB, batteries, cable
Municipal Wastewater Treatment

Municipal Wastewater Treatment · WTW — Stock Configuration Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · WTW — Stock Configuration Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · WTW — Stock Configuration Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.

Power & Energy

Power & Energy · WTW — Stock Configuration Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.