Multi 3510 IDS
MultiLine® 3510 IDS - Digital multiparameter portable meter
MultiLine® 3510 IDS: High-quality portable digital IDS multi-parameter instrument with a universal measurement input for starting with digital measurement technology.
| Variants | ||||
| Art.-No. | Name | Description | ||
| 2FD350 | MultiLine® 3510 IDS | Single unit in field case with buffers 4 and 7, 0,01 mol/l KCl conductivity standard, short instruction manual, CD-ROM including software, batteries, USB cable | ||
| 2FD351 | MultiLine® 3510 IDS Set 1 | Single unit with SenTix® 940 in field case with buffers 4 and 7, 0,01 mol/l KCl conductivity standard, short instruction manual, CD-ROM including software, batteries, USB cable | ||
| 2FD353 | MultiLine® 3510 IDS Set 3 | Single unit with TetraCon® 925 in field case with buffers 4 and 7, 0,01 mol/l KCl conductivity standard, short instruction manual, CD-ROM including software, batteries, USB cable | ||
| 2FD354 | MultiLine® 3510 IDS Set 4 | Single unit with FDO® 925 in field case with buffers 4 and 7, 0,01 mol/l KCl conductivity standard, short instruction manual, CD-ROM including software, batteries, USB cable | ||
| 2FD35U | MultiLine® 3510 IDS Set KS1 | Single unit in field case with buffers 4 and 7, 0,01 mol/l KCl conductivity standard, short instruction manual, stand, beaker, CD-ROM including software, batteries, USB cable, armoring SM Pro | ||
Highlights:
- One unit for up to four parameters: pH/ORP, dissolved oxygen, conductivity, turbidity
- QSC function for optimum tracking of the sensor quality
- Wireless ready
The Multi 3510 IDS compact portable multi-parameter instrument for applications with digital IDS pH/ORP electrodes, dissolved oxygen sensors, conductivity cells or turbidity sensors. Calibration records and additional information are stored in the sensor. Well laid-out menus make the operation safe and easy. With a wide range of electrodes almost every application including depth measurement down to 100 m will be covered in the field and in the laboratory. The delivery also contains the MultiLab® Importer software for data acquisition via Excel®.
The scope of delivery includes the MultiLab® Importer to import data via Excel® as well as the MultiLab® User (user administration).
| MultiLine® | 3510 IDS | 3510 IDS Set 1 | 3510 IDS Set 3 |
| Art.-No. | 2FD350 | 2FD351 | 2FD353 |
| Parameters | pH, ORP, dissolved oxygen, conductivity, turbidity - according to the connected IDS sensor | ||
| Channels | 1 | ||
| Measuring range air pressure | 300 ... 1100 mbar | ||
| Accuracy air pressure | ± 4 mbar | ||
| Operating temperatur | -10 °C ... + 55 °C with pluged-in power supply connected (batterie charging): 0 °C ... + 40 °C |
||
| Protection class | IP 67 | ||
| Data storage | Manually: 500, Automatically: 4.500 | ||
| Contents | Single unit in field case with buffers 4 and 7, 0,01 mol/l KCl conductivity standard, short instruction manual, CD-ROM including software, batteries, USB cable | Single unit with SenTix® 940 in field case with buffers 4 and 7, 0,01 mol/l KCl conductivity standard, short instruction manual, CD-ROM including software, batteries, USB cable | Single unit with TetraCon® 925 in field case with buffers 4 and 7, 0,01 mol/l KCl conductivity standard, short instruction manual, CD-ROM including software, batteries, USB cable |
| MultiLine® | 3510 IDS Set 4 | 3510 IDS Set KS1 |
| Art.-No. | 2FD354 | 2FD35U |
| Parameters | pH, ORP, dissolved oxygen, conductivity, turbidity - according to the connected IDS sensor | |
| Channels | 1 | |
| Measuring range air pressure | 300 ... 1100 mbar | |
| Accuracy air pressure | ± 4 mbar | |
| Operating temperatur | -10 °C ... + 55 °C with pluged-in power supply connected (batterie charging): 0 °C ... + 40 °C |
|
| Protection class | IP 67 | |
| Data storage | Manually: 500, Automatically: 4.500 | |
| Contents | Single unit with FDO® 925 in field case with buffers 4 and 7, 0,01 mol/l KCl conductivity standard, short instruction manual, CD-ROM including software, batteries, USB cable | Single unit in field case with buffers 4 and 7, 0,01 mol/l KCl conductivity standard, short instruction manual, stand, beaker, CD-ROM including software, batteries, USB cable, armoring SM Pro |
Case Studies
Municipal Wastewater Treatment · WTW — Stock Configuration Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.
Food & Beverage · WTW — Stock Configuration Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.
Solution
The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.
Chemical & Pharmaceutical · WTW — Stock Configuration Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.
Power & Energy · WTW — Stock Configuration Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.