Multi 3630 IDS SET KS2
MultiLine® 3630 IDS - Digital multiparameter portable meter
MultiLine® 3630 IDS: High-quality digital portable IDS multi-parameter measuring device with three universal measuring channels.
| Variants | ||||
| Art.-No. | Name | Description | ||
| 2FD570 | MultiLine® 3630 IDS | Single unit in field case with buffer STP 4 and STP 7, 0,01 mol/l KCl conductivity standard solution, short instruction manual, CD-ROM and rechargeable batteries, driver software for USB, cable, power supply, armoring SM Pro | ||
| 2FD57F | MultiLine® 3630 IDS Set F | Multi set in field case with IDS sensors (SenTix® 940, TetraCon® 925, FDO® 925, QSC-Kit (EVE obligatory)), with buffer STP 4 and STP 7, 0,01 mol/l KCl conductivity standard solution, short instruction manual, stand, beaker, CD-ROM and rechargeable batteries, driver software for USB, cable, power supply, armoring SM Pro | ||
| 2FD57G | MultiLine® 3630 IDS Set G | Multi set in field case with IDS sensors (SenTix® 940-3, TetraCon® 925-3, FDO® 925-3, QSC-Kit (EVE-pflichtig)), with buffer STP 4 and STP 7, 0,01 mol/l KCl conductivity standard solution, short instruction manual, stand, beaker, CD-ROM and rechargeable batteries, driver software for USB, cable, power supply, armoring SM Pro | ||
| 2FD57V | MultiLine® 3630 IDS Set KS2 | Single unit in field case with QSC Kit (EVE obligatory), buffer STP 4 and STP 7, 0,01 mol/l KCl conductivity standard solution, short instruction manual, stand, beaker, CD-ROM and rechargeable batteries, driver software for USB, cable, power supply, armoring SM Pro | ||
| 2FD57W | MultiLine® 3630 IDS Set WL | Single unit in field casebuffer STP 4 and STP 7, 0,01 mol/l KCl conductivity standard solution, short instruction manual, CD-ROM and rechargeable batteries, driver software for USB, cable, power supply, armoring SM Pro, IDS WLM-M Module | ||
Highlights:
- One unit for up to four parameters: pH/ORP, dissolved oxygen, conductivity, turbidity
- Measure, display and document three parameters plus secondary information
- Wireless ready
- Digital sensor detection
- Three galvanically isolated sensor inputs
Triple – 3 channels, 4 parameters: Three measuring channels, freely combinable for same or different parameters: The simultaneous multi-parameter measurement without compromise. Use also the wireless modules together with the nee IDS plug head sensors, be independent from cables and measure conveniently also at hardly accessible locations. Another highlight: This meter allows the operation with the digital multi-parameter probes MPP 910 IDS and MPP 930 IDS.
The Multi 3630, just like the MultiLine® series, has a brilliant color graphic display and two USB interfaces. The batteries can be charged directly in the device. The activing user administration can also be used alternatively to mark measuring points. The 10,000 data sets include up to three main parameters, three temperature values as well as the water depth if using the depth probe.
The scope of delivery includes the MultiLab® Importer to capture data via Excel® as well as the MultiLab® User (user administration).
| MultiLine® | 3630 IDS | 3630 IDS Set F | 3630 IDS Set G |
| Art.-No. | 2FD570 | 2FD57F | 2FD57G |
| Parameters | pH, ORP, dissolved oxygen, conductivity, turbidity | ||
| Channels | 3 | ||
| Measuring range air pressure | 300 ... 1100 mbar | ||
| Accuracy air pressure | ± 4 mbar | ||
| Operating temperatur | -10 °C ... + 55 °C with pluged-in power supply connected (batterie charging): 0 °C ... + 40 °C |
||
| Protection class | IP 67 | ||
| Data storage | Manually: 500, Automatically: 10.000 | ||
| Contents | Single unit in field case with buffer STP 4 and STP 7, 0,01 mol/l KCl conductivity standard solution, short instruction manual, CD-ROM and rechargeable batteries, driver software for USB, cable, power supply, armoring SM Pro | Multi set in field case with IDS sensors (SenTix® 940, TetraCon® 925, FDO® 925, QSC-Kit (EVE obligatory)), with buffer STP 4 and STP 7, 0,01 mol/l KCl conductivity standard solution, short instruction manual, stand, beaker, CD-ROM and rechargeable batteries, driver software for USB, cable, power supply, armoring SM Pro | Multi set in field case with IDS sensors (SenTix® 940-3, TetraCon® 925-3, FDO® 925-3, QSC-Kit (EVE-pflichtig)), with buffer STP 4 and STP 7, 0,01 mol/l KCl conductivity standard solution, short instruction manual, stand, beaker, CD-ROM and rechargeable batteries, driver software for USB, cable, power supply, armoring SM Pro |
| MultiLine® | 3630 IDS Set KS2 | 3630 IDS Set WL |
| Art.-No. | 2FD57V | 2FD57W |
| Parameters | pH, ORP, dissolved oxygen, conductivity, turbidity | |
| Channels | 3 | |
| Measuring range air pressure | 300 ... 1100 mbar | |
| Accuracy air pressure | ± 4 mbar | |
| Operating temperatur | -10 °C ... + 55 °C with pluged-in power supply connected (batterie charging): 0 °C ... + 40 °C |
|
| Protection class | IP 67 | |
| Data storage | Manually: 500, Automatically: 10.000 | |
| Contents | Single unit in field case with QSC Kit (EVE obligatory), buffer STP 4 and STP 7, 0,01 mol/l KCl conductivity standard solution, short instruction manual, stand, beaker, CD-ROM and rechargeable batteries, driver software for USB, cable, power supply, armoring SM Pro | Single unit in field casebuffer STP 4 and STP 7, 0,01 mol/l KCl conductivity standard solution, short instruction manual, CD-ROM and rechargeable batteries, driver software for USB, cable, power supply, armoring SM Pro, IDS WLM-M Module |
Case Studies
Municipal Wastewater Treatment · WTW — Stock Configuration Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.
Food & Beverage · WTW — Stock Configuration Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.
Solution
The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.
Chemical & Pharmaceutical · WTW — Stock Configuration Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.
Power & Energy · WTW — Stock Configuration Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.