Product Overview
-
Power supply modules for the IQ SENSOR NET, 230VAC or 24 V AC/DC
-
Module to supply voltage to the system components in the IQ SENSOR NET – thanks to the modular principle and simple installation this is individually customizable:
-
Individually adaptable to the energy requirement - up to 6 modules can be installed in one system
-
Simple mounting - mount anywhere in the system, stacked without additional mounting hardware
-
Integrated lightning protection ensures high operational safety in any weather
-
The power supply modules to operate the IQ SENSOR NET are available in two models: The wide range power supply MIQ/PS for 100–240 VAC and the low-voltage power supply MIQ/24V for 24 VAC/24 VDC.
-
By the ability to stack these in the IQ SENSOR NET, you can quickly and easily dock these modules onto already existing ones - anywhere in the system. Therefore, you will not require any additional mounting hardware.
|
Models |
MIQ module MIQ/PS |
MIQ module MIQ/24V |
|
Order No. |
480004 |
480006 |
|
MIQ Module Coupling at Front |
Combined mechanical and electrical connection for rapid docking and removal of the MIQ/TC 2020 3G |
|
|
MIQ Module Coupling at Rear |
Combined mechanical and electrical connection, for rapid coupling to MIQ modules, up to 3 modules as a stack mounted unit possible |
|
|
Cable Feeds |
4 screw cable glands M 16 x 1.5 |
|
|
Terminal Connections |
Screw terminal strips |
|
|
IQ Sensor Net Terminal Connections |
Terminal connections for the IQ Sensor Net are available on each module and can be used as required: |
|
|
Other Functions |
Two LEDs, yellow and red, for monitoring the operating voltage of the IQ Sensor Net; IQ Sensor Net connection, Integrated local identity function; Integrated switchable terminal resistor (SN terminator) |
|
|
Electric Supply |
Directly via the IQ Sensor Net |
|
|
Ambient Conditions |
Operating temperature: -4 °F … 131 °F (-20 °C … +55 °C); Storage temperature: -13 °F … 149 °F (-25 °C … +65 °C) |
|
|
Housing Material |
PC – 20 % GF (polycarbonate with 20 % fiberglass) |
|
|
Protection Rating |
IP67 |
IP 66 |
|
corresponding to NEMA 4X (not for direct conduit connections). Conduits need to be connected with flexible adapters (CC-Box), respectively with adapters CC-PM.. |
||
|
Dimensions (W x H x D) |
5.67 x 5.67 x 2.05 in. (144 x 144 x 52 mm) |
|
|
Weight |
Approx. 1.1 pounds (0.5 kg) |
|
|
Certifications |
ETL, cETL (conforms with relevant UL and Canadian standards), CE |
|
|
Electromagnetic Compatibility |
EN 61326-1, Class B; FCC Class A |
|
|
Integrated Overvoltage Protection |
According to EN 61326-1 enhanced overvoltage protection for the entire system, implemented in each component |
|
|
Connection Medium Cable |
IQ Sensor Net cable SNCIQ or SNCIQ/UG (underground cable with additional PVC coating): |
|
|
Connection Characteristics |
Energy and data transfer via 2 wire technique; resistant to reversed polarity; Comprehensive EMC shield control; cable topology within IQ Sensor Net system as required, e.g. in the form of a line, tree, star, multiple star; Total cable length: max. 1000 m/1094 yds (without signal amplifying), with signal amplifying module MIQ/JBR additional 1000 m/1094 yds (max 3000 m/3282 yds) |
|
|
Warranty |
3 years for defects of quality |
|
Case Studies
Municipal Wastewater Treatment · WTW — Stock Configuration Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.
Food & Beverage · WTW — Stock Configuration Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.
Solution
The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.
Chemical & Pharmaceutical · WTW — Stock Configuration Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.
Power & Energy · WTW — Stock Configuration Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.