Alyza IQ NH4-110
The perfect solution for monitoring ammonium in the treatment plant effluent as well as surface water bodies – on-site analyzer for ammonium measurement in the IQ SENSOR NET
Ammonium Analyzer for the IQ SENSOR NET:
- Minimized reagent consumption and waste
- Reliable results even at very low NH4 concentrations
- Minimum maintenance
- Easy to operate
- Compatible with IQ SENSOR NET
The Alyza IQ NH4 ammonium analyzer is the latest addition to the IQ SENSOR NET. It can be easily integrated into new and existing systems just as simple as a sensor. The measuring principle is based on the photometric indophenol method according to DIN 38 406, which has been a proven detection method for ammonium. Thanks to the wet chemical measurement directly in the process, Alyza IQ is the perfect solution for monitoring the treatment plant effluent as well as surface water bodies.
Highlights:
- Minimized reagent consumption and waste
Alyza IQ boasts an extremely low use of reagents – an advantage that significantly reduces operating costs and waste generation - Simple Service
Regular maintenance takes only 10 minutes every 2-3 months. - Reliable results from low to high measuring levels
Thanks to the new technology, Alyza IQ provides an accurate and reliable measurement over the whole range of 0.02–5.00 mg/l and 0.10–20.00 mg/l NH4-N. - Automatic cleaning and calibration with standards
The fully automated cleaning as well as 2-point calibration with selectable intervals ensures an exceptional degree of operational safety. - On-site installation
Alyza IQ NH4 can be installed directly at the basin. This guarantees short transport distances and promptly measured values. Thanks to the climate package, the analyzer is perfectly suited for all weathers.
Models:
Alyza IQ NH4-110 NH4 analyzer, 2 measurement ranges, 1 channel
Alyza IQ NH4-111 NH4 analyzer, 2 measurement ranges, 1 channel, incl. pump
Alyza IQ NH4-112 NH4 analyzer, 2 measurement ranges, 2 channels, incl. 2 pumps
Applications:
- Wastewater treatment plant effluent monitoring
- River monitoring
| Model | Alyza IQ NH4-110 | Alyza IQ NH4-111 | Alyza IQ-NH4-112 |
| Order No. | 825010 | 825011 | 825012 |
| Measurement method | Berthelot method (Indophenol method) | ||
| Measurement range | Two measuring ranges: | ||
|
MR1: Displayed: Resolution: Accuracy: |
0.02 … 5.00 mg/l NH4-N 0.00 … 5.00 mg/l NH4-N 0.01 mg/l NH4-N ± 2 % ± 0.02 mg/l |
||
|
MR2: Displayed: Resolution: Accuracy: |
0.10 … 20.00 mg/l NH4-N 0.00 … 20.00 mg/l NH4-N 0.01 mg/l NH4-N ± 3 % ± 0.10 mg/l |
||
| Sample streams/channels | 1 | 1 | 2 |
| Cleaning | Automatic cleaning with cleaning solutions | ||
| Calibration | Automatic 1- and 2-point calibrations | ||
| Operational temperature | -4 ... 104 °F (-20 … +40) °C | ||
Case Studies
Municipal Wastewater Treatment · WTW — Stock Configuration Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.
Food & Beverage · WTW — Stock Configuration Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.
Solution
The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.
Chemical & Pharmaceutical · WTW — Stock Configuration Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.
Power & Energy · WTW — Stock Configuration Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.