Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

825511 Alyza IQ PO4-111

825511 Alyza IQ PO4-111

Alyza IQ PO4-111

WTW 825511
Orthophosphate analyzer Alyza IQ PO4 for the IQ Sensor Net, Measurement range 1, 1-channel with pump. Scope of delivery: Orthophosphate analyzer for indoor and outdoor use, spare parts for the first year, pre-installed 2 m SNCIQ and power cables (please order controller and reagents separately).

The perfect solution to support phosphate elimination as well as phosphate load monitoring – on-site analyzer for orthophosphate measurement in the IQ SENSOR NET

Orthophosphat analyzer for the IQ SENSOR NET

  • Minimized reagent consumption and waste
  • Simple Service-Regular maintenance takes only 10 minutes every 3 months
  • Reliable results from low to high measuring levels
  • Compatible with IQ SENSOR NET

The Alyza IQ PO4 orthophosphate analyzer is another component for the IQ SENSOR NET. It can be easily integrated into new and existing systems just as simple as a sensor. The measuring principle is based on the photometric yellow method (molybdate vanadate), which has been a proven detection method for orthophosphate. Thanks to the wet chemical measurement directly in the process, Alyza IQ is the perfect solution to support phosphate elimination as well as monitoring the phosphate load.


Highlights:

  • Minimized reagent consumption and waste
    Alyza IQ boasts an extremely low use of reagents - an advantage that significantly reduces operating costs and waste generation
  • Simple Service
    Regular maintenance takes only 10 minutes every 3 months.
  • Reliable results from low to high measuring levels
    Thanks to the new technology, Alyza IQ provides an accurate and reliable measurement over the whole range of 0.02-15.00 mg/l and 0.2-50.0 mg/l PO4-P.
  • Automatic cleaning and calibration with standards
    The fully automated cleaning as well as 1- or 2-point calibration with selectable intervals ensures an exceptional degree of operational safety.
  • On-site installation
    Alyza IQ PO4 can be installed directly at the basin. This guarantees short transport distances and promptly measured values. Thanks to the climate package, the analyzer is perfectly suited for all weathers.

Models:

Alyza IQ PO4-110 PO4 analyzer, measurement range 1, 1-channel
Alyza IQ PO4-111 PO4 analyzer, measurement range 1, 1-channel, incl. pump
Alyza IQ PO4-112 PO4 analyzer, measurement range 1, 2-channel, incl. pump
Alyza IQ PO4-120 PO4 analyzer, measurement range 2, 1-channel
Alyza IQ PO4-121 PO4 analyzer, measurement range 2, 1-channel, incl. pump
Alyza IQ PO4-122 PO4 analyzer, measurement range 2, 2-channel, incl. pump


Applications:

  • Precipitation control
  • Wastewater treatment plant effluent monitoring
Alyza IQ PO4 -110 -111 -112 -120 -121 -122
Order No. 825510 825511 825512 825520 825521 825522
       detailed technical data see data sheet D2.25
Measurement method Molybdate-Vanadate method (Yellow method)
Measurement range MR1: 0.02 … 15.00 mg/l PO4-P MR2: 0.2 … 50.0 mg/l PO4-P
Displayed:

0.00 … 15.00 mg/l PO4-P

0.0 … 50.0 mg/l PO4-P

Resolution:

0.01 mg/l PO4-P

0.05 mg/l PO4-P
Accuracy:

±2 % ±0.02 mg/l

±2 % ±0.2 mg/l
Sample streams/channels 1 1 2 1 1 2
Cleaning  Automatic cleaning with cleaning solutions
Calibration  Automatic 1- and 2-point calibrations
Operational temperature -4 ... 104 °F (-20 … +40) °C
Municipal Wastewater Treatment

Municipal Wastewater Treatment · WTW — Stock Configuration Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · WTW — Stock Configuration Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · WTW — Stock Configuration Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.

Power & Energy

Power & Energy · WTW — Stock Configuration Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.