Application Industries:
The 2100Q portable turbidimeter is mainly used in environmental protection, tap water, health and disease control, government and universities, municipal water supply, industrial water, pharmaceutical industry, wastewater treatment, etc.
Instrument Features:
-
Compact and lightweight, suitable for field and emergency measurement occasions. Utilizing HACH's ratio measurement technology, the measurement results are more accurate and reliable. The system's unique rapid settling mode determines whether the sample has reached steady state, avoiding errors that may arise from human judgment. IP67 protection class makes field measurement more reassuring and reliable.
-
Optical system capable of precise on-site testing
-
The optical system of the 2100Q portable turbidimeter utilizes HACH's ratio measurement technology and features a dual-detector optical system that compensates for sample color, light fluctuations, and stray light. For most samples, even under harsh field conditions, it maintains laboratory-grade measurement performance and delivers accurate and reliable measurement results.
-
Accurately measures rapidly settling samples
-
The 2100Q portable turbidimeter employs an innovative Rapid Settling Turbidity (RST) measurement mode. For rapidly settling samples that are difficult to measure, the 2100Q provides accurate and reproducible measurement results. Based on a series of automatic readings, a special algorithm calculates the turbidity value without the need for extra measurements and estimations.
-
Convenient data transfer
-
With the optional USB+Power Module, data transfer from the 2100Q portable turbidimeter is very convenient and flexible, requiring no additional software. All data can be transferred to the module and downloaded to a computer via USB connection, providing you with useful and complete data. The 2100Q has two different modules available, allowing you to choose the connection method and power supply method according to your own needs.
-
Convenient data storage function
-
The 2100Q portable turbidimeter can automatically store up to 500 measurement values, making it easy for users to access and back up. The stored information includes: date and time, operator ID, reading mode, sample ID, sample number, unit, calibration time, calibration status, error messages, and results.
-
Easy calibration and verification
-
The 2100Q portable turbidimeter's calibration and verification Chinese prompt function saves you time and ensures accuracy. The operation interface is simple. For routine calibration, it can be completed without referring to complex operation manuals. Single-point Rapid-CaI calibration provides a simple solution for low-range measurement.
Technical Specifications
-
Measuring method Ratio measurement technology - 90-degree scattered light and transmitted light
-
Compliant regulations Complies with EPA Method 180.1
-
Measuring range 0-1000NTU
-
Accuracy Between 0-1000NTU, accuracy is ±2% of reading plus stray light
-
Resolution 0.01NTU at the lowest range
-
Stray light <0.02NTU(FNU)
-
Reading modes (user selectable) Normal mode (press key to read) Signal averaging Rapid settling turbidity
-
Data storage 500 data sets
-
Power requirements AC100-240V, 50/60Hz (using power supply or USB+Power Module);
-
4AA alkaline batteries;
-
Rechargeable NiMH batteries (used together with USB+Power Module)
-
Languages Selectable USB Chinese, English, etc., 22 languages
-
Interface Selectable USB
-
Instrument protection class IP67 (except sealed cover and battery compartment)
Related Reagents
| Order No. | Description | Parameter | Analysis Method | Packaging | Measuring Range | Guaranteed Shelf Life (days) |
|---|---|---|---|---|---|---|
| 2659405-CN | STABLCAL ampoule kit, 2100P | Turbidity | 180.1 | 4 vials, sealed | 0-1,000NTU | |
| 2660549-CN | STABLCAL standard, 800NTU, 500mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
- | - | 150 |
| 2464105 | GELEX standard kit, 2100 portable TURBS | - | Turbidity 180.1 0-1,000 NTU Turbidity 180.1 0-10,000 NTU Turbidity 180.1 0-100 NTU Turbidity 180.1 0-4,000 NTU Turbidity 7027 0-1,000 FNU Turbidity 7027 0-10,000 FNU Turbidity 7027 0-4,000 NTU |
3-pack | 0 | 180 |
| 2660149-CN | STABLCAL standard solution, 20NTU, 500mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
- | - | 365 |
| 126936-CN | Silicone oil 15mL, SCDB | - | Turbidity 8237 0-1,000 FAU Turbidity 8237 21-1000 FAU |
15mL | 0 | 150 |
| 2660249-CN | STABLCAL standard solution, 100NTU, 500mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
500mL | 0 | 150 |
| 2660142-CN | STABLCAL standard solution, 20NTU, 100mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
- | - | 150 |
| 246142-CN | FORMAZIN turbidity standard solution, 4000NTU, 100mL | Turbidity | Turbidity 180.1 0-1,000 NTU Turbidity 180.1 0-10,000 NTU Turbidity 180.1 0-100 NTU Turbidity 180.1 0-4,000 NTU Turbidity 7027 0-1,000 FNU Turbidity 7027 0-10,000 FNU Turbidity 7027 0-4,000 NTU |
100mL | 0 | 150 |
| 2659949-CN | STABLCAL standard solution, 10NTU, 500mL | Turbidity | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
500mL | 0 | 150 |
| 2659842-CN | STABLCAL standard solution, 1.0NTU, 100mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
- | - | 150 |
| 2589200 | GELEX SEC turbidity standard kit, 2100AN | Turbidity | 180.1 | 6-pack | 0-100NTU | |
| 2589000 | GELEX SEC turbidity test kit, 2100N | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
5-pack | 0 | |
| 2660242-CN | STABLCAL standard solution, 100NTU, 100mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
100mL | 0 | 150 |
| 2659942-CN | STABLCAL standard solution, 10NTU, 100mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
100mL | 0 | 150 |
| 2660449-CN | STABLCAL standard, 200NTU, 500mL | - | Turbidity 8237 0-1,000 FAU Turbidity 8237 21-1000 FAU |
500mL | 0 | 150 |
| 2660649-CN | STABLCAL standard, 1000NTU, 500mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
500mL | 0 | 150 |
| 2660642-CN | STABLCAL standard, 1000NTU, 100mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
100mL | 0 | 150 |
| 2660442-CN | STABLCAL standard, 200NTU, 100mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
100mL | 0 | 150 |
| 2659749-CN | STABLCAL solution, <0.1NTU, 500mL | - | Turbidity 180.1 0-4,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-1,000NTU |
500mL | 0 | 150 |
| 2659400-CN | STABLCAL calibration kit, 2100P | Turbidity | 180.1 | 4-pack | 0-1,000NTU | 150 |
| 2698042-CN | STABLCAL verification standard solution, 0.50NTU, 100mL | - | Turbidity 180.1 0-4,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-1,000NTU Turbidity 7027 0-1,000FNU Turbidity 7027 0-4,000NTU |
100mL | 0 | 150 |
| 2697942-CN | STABLCAL verification standard solution, 0.30NTU, 100mL | - | Turbidity 7027 0-1,000 FNU Turbidity 7027 0-4,000 NTU Turbidity 180.1 0-100 NTU Turbidity 180.1 0-1,000 NTU Turbidity 180.1 0-4,000 NTU |
100mL | 0 | 150 |
| 2659849-CN | STABLCAL standard, 1.0NTU, 500mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
- | - | 150 |
| 2723342-CN | STABLCAL verification standard solution, 0.10NTU, 100mL | - | Turbidity 180.1 0-100 NTU Turbidity 180.1 0-4,000 NTU |
100mL | 0 | 150 |
| 2659742-CN | STABLCAL solution, <0.1NTU, 100mL | - | Turbidity 180.1 0-1,000NTU Turbidity 180.1 0-10,000NTU Turbidity 180.1 0-100NTU Turbidity 180.1 0-4,000NTU |
100mL | 0 | 365 |
| 2659410-CN | STABLCAL calibration kit, 2100P | Turbidity | 180.1 | 4-pack | 0-1,000NTU | 150 |
Spare Parts
| Spare Part Order No. | Instrument Model | Chinese Description | English Description |
|---|---|---|---|
| 4653900 | 2100Q Portable Turbidimeter | Lamp | LAMP ASSY |
| YAB110 | 2100Q Portable Turbidimeter | Mainboard (EPA) | ZBA949,PCBA MAINBOARD |
| YAB111 | 2100Q Portable Turbidimeter | Mainboard (ISO) | ZBA950,PCBA MAINBOARD |
Accessory Information
-
Order No. Description
-
LQV161.53.10000 Thermal printer
-
58360-00 Printing paper for Citizen PD-24 printer, 5/pk
-
29712-05 StabICal-grade standard solution in sealed vials
-
LZV813 USB+Power Module
Ordering Guide
-
Order No. Description
-
2100Q-01 2100QIS-01 Includes main unit, carrying case, alkaline batteries, StabICal primary calibration solution, 10NTU primary verification standard, 6 sample cells, instrument operation manual, quick start guide, silicone oil, and oil cloth.
Source: HACH Water Quality website public information
Casos de servicio
Tratamiento de Aguas Residuales Municipales — Hach-Lab: caso de aplicación
Resumen del proyecto
La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hach-Lab en la planta existente, con el objetivo de análisis de agua colorimétrico y volumétrico en laboratorio.
Retos técnicos
Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hach-Lab deba incluir selección por método, volumen de muestras y kit de reactivos.
Configuración
El suministro y la instalación se organizaron por la vía de laboratorio: configurar según métodos de laboratorio y volumen de muestras. En planta esto supuso selección por método, volumen de muestras y kit de reactivos; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.
Comportamiento
Tras la puesta en marcha el resultado es métodos normalizados que hacen comparables los datos entre laboratorios, y las lecturas se usan ya para ajustar el proceso.
Alimentación y Bebidas — Hach-Lab: caso de aplicación
Situación en planta
Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis de agua colorimétrico y volumétrico en laboratorio.
El problema
La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por método, volumen de muestras y kit de reactivos.
Qué hicimos
Adoptamos un enfoque de laboratorio: configurar según métodos de laboratorio y volumen de muestras. La entrega se construyó en torno a selección por método, volumen de muestras y kit de reactivos; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.
Resultado operativo
En servicio el sistema responde a lo previsto: métodos normalizados que hacen comparables los datos entre laboratorios, con un mantenimiento rutinario notablemente menor.
Química y Farmacéutica — Hach-Lab: caso de aplicación
Contexto de aplicación
reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hach-Lab, centrándose en análisis de agua colorimétrico y volumétrico en laboratorio.
Limitaciones del proceso
la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hach-Lab debe cubrir selección por método, volumen de muestras y kit de reactivos.
Enfoque de suministro
La entrega se gestionó como laboratorio: configurar según métodos de laboratorio y volumen de muestras. La ejecución se centró en selección por método, volumen de muestras y kit de reactivos, junto con certificación Ex y trazabilidad de datos según GMP.
Resultados en campo
La operación evidencia el beneficio: métodos normalizados que hacen comparables los datos entre laboratorios, con una confianza claramente mayor en este punto de medición.
Energía y Electricidad — Hach-Lab: caso de aplicación
Perfil del cliente
El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hach-Lab; el foco es análisis de agua colorimétrico y volumétrico en laboratorio.
Dificultades clave
Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por método, volumen de muestras y kit de reactivos.
Implementación
El alcance se canalizó por la vía de laboratorio: configurar según métodos de laboratorio y volumen de muestras. Técnicamente se apoya en selección por método, volumen de muestras y kit de reactivos, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.
Beneficio para el cliente
En la práctica esto significa métodos normalizados que hacen comparables los datos entre laboratorios, lo que redujo la carga del equipo de mantenimiento.
Recomendados similares
HACHDigestor (digestor rápido de COD)
HACHSerie de tiras reactivas para análisis de agua
HACHAnalizador electroquímico multicanal
HACHMedidor de bolsillo de agua Pro/Pro+
HACHColorímetro de líquidos
HACHAnalizador portátil de toxicidad del agua
HACHValorador potenciométrico automático serie 1000
HACH