Instrumentación · Ingeniería · Paquete · PLC
0755-82221901 sales@ainstru.com

5100010Descontinuado

5100010
APA6000 Alkalinity AnalyzerDescontinuado
HACH 5100010
Reliable, accurate, continuous measurement of alkalinity.

产品概述

Reliable, accurate, continuous measurement of alkalinity.

Each analyzer includes an installation kit, one month's supply of reagents, a maintenance kit, a sample conditioning kit, an illustrated manual, and a quick reference card. Power cords must be ordered separately.

主要特点

  • Accurate, continuous analysis:The APA6000 provides an accurate measurement of alkalinity for your process.
  • Completely automated:The analyzer autocalibrates, set-and-forget operation frees time for other tasks.
  • Very low maintenance:The analyzer is self-cleaning, self-calibrating, and selfpriming. Reduced sample volume minimizes reagent use and allows instrument to run up to 30 days in clean water applications before maintenance and reagent replenishment.
  • Advanced process control:Two 4 - 20 mA outputs and two alarm relays allow quick configuration into standard PID control loop. Can be expanded up to 14 4-20 mA outputs and 14 alarm relays.
  • Constant protection:Fast and accurate response minimizes process excursions.

技术参数

参数名称说明
Depth(21")
Height(21")
Width(25")
AccuracyBetter than ± 5 % of reading or ± 1 mg/L whichever is greater
Analog OutputsTwo 4-20 mA outputs suitable for recorders or PID control. Output span programmable over any portion of the 1 to 500 mg/L range (130 Vac isolation from earth ground)
Calibration Interval60 minutes
CertificationsNRTL certified to UL and CSA standards and CE approved
Cycle Time8 minutes
Data Communications DistanceMaximum node-to-node distance is 400 m (1312'). Maximum total wire length is 500 m (1640')
Dimensions (H x W x D)522 mm x 627 mm x 526 mm
DrainGravity, air break or vent recommended
Drain Fitting1/4" OD NPT barbed hose fitting
Enclosure RatingNEMA 4X (indoor)/IEC 529 (IP66) with provision for air purge. Reagent enclosure is drip-proof.
InletSample filter: 3/4" NPT male or female
MountingWall, bench and panel
ParameterAlkalinity
Power Requirements (Hz)50/60 Hz
Power Requirements (Voltage)90 - 240 V AC
Range1 - 1000 mg/L total alkalinity as CaCO3 5 - 1000 mg/L CaCO3 as phenolphthalein alkalinity
Relay OutputTwo SPDT relays with contacts rated for 5A resistive load at 230 Vac. Additional relays available through optional Signal Output Module.
RepeatabilityBetter than 3 % of reading or ± 0.6 mg/L, whichever is greater
Response TimeLess than 10 minutes for 90% response to setup change at instrument sample fitting
Sample Flow Rate20 - 1000 mL/min
Sample IntervalOptionally capable of analyzing up to three sample streams
Sample Pressure0.03 - 6.9 bar
Sample Temperature5 - 50 °C (41 - 122 °F)
Weight25.5 kg
What's included?APA6000 Alkalinity analyzer, installation kit, one month's supply of reagents, a maintenance kit, Hach user manual.