Reliable, accurate, continuous measurement of alkalinity.

产品概述

Reliable, accurate, continuous measurement of alkalinity.

Each analyzer includes an installation kit, one month's supply of reagents, a maintenance kit, a sample conditioning kit, an illustrated manual, and a quick reference card. Power cords must be ordered separately.

主要特点

  • Accurate, continuous analysis:The APA6000 provides an accurate measurement of alkalinity for your process.
  • Completely automated:The analyzer autocalibrates, set-and-forget operation frees time for other tasks.
  • Very low maintenance:The analyzer is self-cleaning, self-calibrating, and selfpriming. Reduced sample volume minimizes reagent use and allows instrument to run up to 30 days in clean water applications before maintenance and reagent replenishment.
  • Advanced process control:Two 4 - 20 mA outputs and two alarm relays allow quick configuration into standard PID control loop. Can be expanded up to 14 4-20 mA outputs and 14 alarm relays.
  • Constant protection:Fast and accurate response minimizes process excursions.

技术参数

参数名称说明
Depth(21")
Height(21")
Width(25")
AccuracyBetter than ± 5 % of reading or ± 1 mg/L whichever is greater
Analog OutputsTwo 4-20 mA outputs suitable for recorders or PID control. Output span programmable over any portion of the 1 to 500 mg/L range (130 Vac isolation from earth ground)
Calibration Interval60 minutes
CertificationsNRTL certified to UL and CSA standards and CE approved
Cycle Time8 minutes
Data Communications DistanceMaximum node-to-node distance is 400 m (1312'). Maximum total wire length is 500 m (1640')
Dimensions (H x W x D)522 mm x 627 mm x 526 mm
DrainGravity, air break or vent recommended
Drain Fitting1/4" OD NPT barbed hose fitting
Enclosure RatingNEMA 4X (indoor)/IEC 529 (IP66) with provision for air purge. Reagent enclosure is drip-proof.
InletSample filter: 3/4" NPT male or female
MountingWall, bench and panel
ParameterAlkalinity
Power Requirements (Hz)50/60 Hz
Power Requirements (Voltage)90 - 240 V AC
Range1 - 1000 mg/L total alkalinity as CaCO3 5 - 1000 mg/L CaCO3 as phenolphthalein alkalinity
Relay OutputTwo SPDT relays with contacts rated for 5A resistive load at 230 Vac. Additional relays available through optional Signal Output Module.
RepeatabilityBetter than 3 % of reading or ± 0.6 mg/L, whichever is greater
Response TimeLess than 10 minutes for 90% response to setup change at instrument sample fitting
Sample Flow Rate20 - 1000 mL/min
Sample IntervalOptionally capable of analyzing up to three sample streams
Sample Pressure0.03 - 6.9 bar
Sample Temperature5 - 50 °C (41 - 122 °F)
Weight25.5 kg
What's included?APA6000 Alkalinity analyzer, installation kit, one month's supply of reagents, a maintenance kit, Hach user manual.

资料下载