Instrumentación · Ingeniería · Paquete · PLC
0755-82221901 sales@ainstru.com

B5AFAA152AAF2

B5AFAA152AAF2
Familia de producto: Hach BioTector B3500c TOC Analyzers
Hach BioTector B3500c Online TOC Analyzer, 0 - 100 mg/L C, 2 streams, 115 V AC
HACH B5AFAA152AAF2
Maximum uptime and reliability for TOC analysis in condensate applications

产品概述

Maximum uptime and reliability for TOC analysis in condensate applications

Through patented technology and semi-annual reagent replacement, the BioTector B3500c delivers 99.86% uptime with the lowest operating cost in condensate applications. The B3500c can also be configured to measure Total Inorganic Carbon (TIC), enabling flexible system setups for TIC & TOC (NPOC), TC, or VOC analyzis based on specific monitoring needs. This allows the analyzer to accurately assess inorganic and organic carbon content to match the requirements of your application. Reliable and accurate TOC and TIC monitoring allows plants to make confident decisions that protect capital equipment and avoid downtime. The BioTector B3500c, through its innovative oxidation technology, provides maximum reliability and uptime without sacrificing accuracy. With the option to configure for TIC & TOC (NPOC), TC, or VOC analyzis, the B3500c supports monitoring of Total Inorganic Carbon in addition to Total Organic Carbon, giving users the flexibility to match testing approaches to their patented process needs. Industry-leading reliability combined with low total cost of ownership make the B3500c a natural choice for continuous TOC and TIC monitoring in condensate applications.

For more details, to discuss specific application requirements, or to request additional BioTector versions, please contact us. Our team is ready to help identify the right solution for your plant.

Direct measurement of Total Organic Carbon, Total Inorganic Carbon, Total Carbon Chemical Oxygen Demand, Biological Oxygen Demand via correlation Volatile Organic Carbon via calculation

主要特点

  • Worry-free TOC:With a patented Two Stage, Advanced Oxidation Technology system, the B3500c provides you with maximum reliability and uptime, without sacrificing accuracy.
  • Lowest Cost of Ownership:Requiring you to replenish reagents, replace the pump tube, and calibrate only twice a year, the Hach BioTector B3500c has the lowest operating cost available.
  • Small Footprint = CriticalWall Space Savings:With one of the most compact analyzer footprints, this analyzer frees up wall space for other needed instruments.
  • Reagent Costs that Don't Kill the Bottom Line:By only needing to replenish reagents every six months, you will see direct bottom line savings in comparison to other systems requiring bi-weekly or monthly replacements.
  • One Instrument for Multiple Streams:Providing the ability to monitor two streams at the same time, eliminates the double-cost of needing two separate analyzers.

技术参数

参数名称说明
Ambient Temperature5 - 45 °C (41 - 113 °F)
CommunicationModbus RTU, Modbus TCP/IP & Profibus (when the Profibus option is selected, the digital output signals are sent through the Profibus converter with its specific communication protocol) Except for Zone 1 certification then Modbus RTU, Modbus TCP/IP & Modbus TCP/IP Redundant is available
Cycle TimeFrom 5.5 minutes, depending on range and application
Data StoragePrevious 9999 reaction data
DisplayHigh contrast 40 character x 16 line backlit LCD with LED backlight
EExp / Hazardous LocationCertification options are available to European Standards, (ATEX Zone 1, Zone 2), North American Standards (Class I Division 2) and IECEx Zone 1
Exceedance TrackingFull exceedance tracking up to 100 mg/L C
Humidity5 - 85 % (non-condensing)
LanguagesEnglish
Measurement MethodInfrared Measurement of CO₂ after Oxidation (DIN EN 1484:1997-08, ISO 8245:1999-03, EPA 415.1)
Multi-StreamUp to 2 process streams and grab sample
Number of Channels2 Channel / Grab sample-Calibration Port (includes three 4-20mA outputs enabled as standard)
Number of streams2
Oxidation MethodPatented Two-Stage Advanced Oxidation Process (TSAO) using Hydroxyl Radicals
ParameterDirect measurement of Total Organic Carbon, Total Inorganic Carbon, Total Carbon Chemical Oxygen Demand, Biological Oxygen Demand via correlation Volatile Organic Carbon via calculation
Particle SizeUp to 100 µm
Permissible Chloride RangeUp to 30 % w/v
Power Requirements (Hz)60 Hz
Power Requirements (Voltage)115 VAC
Power SupplyTIC/TOC - 115V
Protection ClassIP44, standard fan cooled, maximum ambient temperature 45 °C IP54, air cooled, maximum ambient temperature 35 °C IP54, vortex cooled, maximum ambient temperature 50 °C
Range0 - 100 mg/L C
Range SelectionAutomatic or Manual Range Selection
Repeatability0 - 25 mg/L C: ± 3 % of reading or ± 0.03 mg/L, whichever is greater; Lower limit of detection LOD = 0.06 mg/L Exceedance tracking 0 - 100 mg/L C: 5% of reading or 0.5 mg/L C, whichever is greater
Sample Inlet Temperature0 - 60 °C
Service Interval6 month service intervals
User InterfaceMicrocontroller with membrane keyboard
Warranty12 months
Warranty1
Weight46 kg
What's included?Includes: B3500c analyzer, Tubing, Fuses, Ferrules, Drain, Acid & Base Dip Tubes, C02 Filter & B3500c User Manual

应用领域

Boiler Water · Pre-Treatment · Product Loss · Regulations · Ultrapure Water · Water Conditioning

同系列其他配置

型号
B5ACAA152AAC2Hach BioTector B3500c Online TOC Analyzer, 0 - 25 mg/L C, 1 stream, 11
B5ACAA152AAF2Hach BioTector B3500c Online TOC Analyzer, 0 - 25 mg/L C, 2 streams, 1
B5AFAA152AAC2Hach BioTector B3500c Online TOC Analyzer, 0 - 100 mg/L C, 1 stream, 1

资料下载

4 modelos · clic para contraer