HACH DR4900-US
Modelos configurables 2 models
DR4900 Laboratory Spectrophotometer for water analysis

产品概述

Bringing Effortless Accuracy to Your Lab

Built on the trusted legacy of the DR3900, the DR4900 Spectrophotometer increases analytical reliability and strengthens your laboratory’s operational performance. Engineered for routine and high‑throughput water analysis, the instrument combines stable optics, automated verification functions, and streamlined workflows to deliver consistent, traceable results across a wide range of parameters. Accurate, reproducible data is fundamental for laboratory oversight. The DR4900 reduces sources of analytical variability by integrating diagnostic controls, guided workflows, and an interface designed to standardize testing steps. The result is fewer repeat analyses, reduced operator‑dependent variation, and better confidence in day‑to‑day results. The DR4900 Lab Spectrophotometer with a built-in workflow camera features barcode-based TNTplus vial recognition. The system automatically identifies the correct method for each vial, minimizing manual errors and ensuring compliance and method traceability. Technical Innovations That Protect Data Integrity 10-inch High‑Resolution Touchscreen The large, full‑color display enables rapid navigation of analytical steps, clear visualization of spectral data, and fast review of sample information. The modern UI is optimized for multi‑operator labs, reducing training time and minimizing navigation errors. Integrated Turbidity Diagnostics Optical monitoring verifies whether sample turbidity may interfere with TNTplus vial measurements. The system alerts the operator when filtration or additional sample preparation is recommended, helping maintain result accuracy in samples with suspended solids. Temperature Monitoring for Vial Tests An integrated temperature sensor evaluates vial temperature prior to measurement. This helps ensure that exothermic reactions or insufficient equilibration times do not impact analytical output, particularly important for temperature‑sensitive colorimetric methods. With more than 250 pre‑programmed Hach methods, including a broad range of regulatory‑relevant parameters, the DR4900 supports standardized workflows and consistent method execution. Its robust optical design and built‑in diagnostics help maintain instrument performance over time, giving you greater oversight and control over daily testing operations. Trust the DR4900 Lab Spectrophotometerto deliver reliable, repeatable water quality data while improving analytical efficiency across your laboratory.

主要特点

  • Proven Technology, Modern Interface:The DR4900 Spectrophotometer maintains the trusted core of the DR3900, now enhanced with a 10” screen and modern user interface that helps reduce training time and speed up routine workflows. It’s the familiar performance lab professionals trust—elevated for modern needs.
  • Ensuring Reliable Results with Unrivaled Diagnostic Features:Temperature and turbidity diagnostics help prevent common testing errors -- reducing rework and ensuring consistent accuracy. When using Hach TNTplus vial chemistries, the DR4900 automatically checks the temperature and turbidity of your test, providing you with alerts when out of range, giving you the confidence you need in every measurement.
  • Complete Confidence - From Start to Finish:DR4900 users benefit from end-to-end expertise across instruments, chemistries, and service. So you get faster resolutions, deeper insights, and consistent results from a single partner.
  • DR4900 options to fit your workflow:Two versions of the DR4900 are available: one without an external camera (LPV451.99.00021) or with an external camera (LPV451.99.00121) to enable Smart Workflow features including Certificate of Analysis QR code scanning and Sample ID Text Recognition. • Without Camera (LPV451.99.00021) Delivers the full DR4900 analytical performance and error prevention features for routine lab workflows • With Camera (LPV451.99.00121) Includes all DR4900 performance features plus an external camera that enables Smart Workflow capabilities such as Certificate of Analysis QR code scanning and Sample ID Text Recognition - reducing manual data entry and supporting documentation tracking directly at the instrument.

技术参数

参数名称说明
Accuracy±1.5 nm (340 - 900 nm)
Altitude2000 m maximum
CameraYes
CertificationsCE, UKCA, CMIM, FCC, ISED, certified to UL and CSA safety standards by TÜV
Data Logger> 10,000 measured values (measured values, date, time, sample ID, user ID)
Dimensions (H x W x D)226 mm x 255 mm x 344 mm
Display10 inch (25.4 cm)
Enclosure RatingIP20
Indoor/OutdoorIndoor
InterfacesUse only shielded cable with maximum length of 3 m (9.8 ft) for: USB type A and type C (front side) USB type A and type C (back side) Use only shielded cable (e.g., STP, FTP, S/FTP) with maximum length of 20 m (65.6 ft) for: 1x Ethernet
Light SourceHalogen lamp
Operating Conditions50 - 104 °F (10 - 40 °C ), maximum 80% relative humidity, non-condensing
Operating ModeTransmittance (%), absorbance (Abs) or concentration
Optical SystemReference beam, spectral
Over voltage categoryII
Photometric Accuracy5 mAbs at 0.0 - 0.5 Abs 1% at 0.50 - 2.0 Abs
Photometric Linearity< 0.5% - 2 Abs ≤ 1% at > 2 Abs with neutral glass at 546 nm
Photometric Measuring Range±3.0 Abs (340 - 900 nm)
Pollution Degree2
Power Requirements (Hz)50/60 Hz
Power Requirements (Voltage)100 - 240 VAC
Power SupplyBenchtop Power Supply
Preprogrammed Methods˃ 240
Protection ClassClass I
Sample Cell CompatibilityRectangular: 10 mm, 50 mm, 1 inch Round: 13 mm, 16 mm, 1 inch
Scanning Speed≥ 8 nm/s (in increments of 1 nm)
Spectral Bandwidth5 nm
Storage Conditions-40 - 140 °F (-40 - 60 °C), maximum 80% relative humidity, non-condensing
Stray Light< 0.1% T at 340 nm with NaNO₂
User Programs˃ 100 user programs
Warranty12 months
Warranty1
Wavelength Accuracy± 1.5 nm (wavelength range 320 - 900 nm)
Wavelength CalibrationAutomatic
Wavelength Range320 - 1100 nm
Wavelength Reproducibility± 0.1
Wavelength Resolution1
Wavelength SelectionAutomatic, based on the procedure selected
Weight4.8 kg (10.58 lb)
What's included?Spectrophotometer DR4900; adapter "A" for 1 inch round cell, 10 mm rectangular cell + Accuvac vials; sample cells (matched pair); light shield; dust cover; power cord with country-specific adapter plug; power adapter; camera; user manual

应用领域

Discharge · Groundwater · Influent for Wastewater · Municipal Water · Nutrient Monitoring · Potable Water · Production Water · QA/QC Lab · Regulations · Secondary Treatment · Surface Water · Water Reuse

同系列其他配置

型号
LPV451.99.00021DR4900 Laboratory Spectrophotometer, without camera

资料下载

2 modelos · clic para contraer
Tratamiento de Aguas Residuales Municipales

Tratamiento de Aguas Residuales Municipales — Hach-Lab: caso de aplicación

Resumen del proyecto

La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hach-Lab en la planta existente, con el objetivo de análisis de agua colorimétrico y volumétrico en laboratorio.

Retos técnicos

Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hach-Lab deba incluir selección por método, volumen de muestras y kit de reactivos.

Configuración

El suministro y la instalación se organizaron por la vía de laboratorio: configurar según métodos de laboratorio y volumen de muestras. En planta esto supuso selección por método, volumen de muestras y kit de reactivos; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.

Comportamiento

Tras la puesta en marcha el resultado es métodos normalizados que hacen comparables los datos entre laboratorios, y las lecturas se usan ya para ajustar el proceso.

Alimentación y Bebidas

Alimentación y Bebidas — Hach-Lab: caso de aplicación

Situación en planta

Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis de agua colorimétrico y volumétrico en laboratorio.

El problema

La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por método, volumen de muestras y kit de reactivos.

Qué hicimos

Adoptamos un enfoque de laboratorio: configurar según métodos de laboratorio y volumen de muestras. La entrega se construyó en torno a selección por método, volumen de muestras y kit de reactivos; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.

Resultado operativo

En servicio el sistema responde a lo previsto: métodos normalizados que hacen comparables los datos entre laboratorios, con un mantenimiento rutinario notablemente menor.

Química y Farmacéutica

Química y Farmacéutica — Hach-Lab: caso de aplicación

Contexto de aplicación

reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hach-Lab, centrándose en análisis de agua colorimétrico y volumétrico en laboratorio.

Limitaciones del proceso

la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hach-Lab debe cubrir selección por método, volumen de muestras y kit de reactivos.

Enfoque de suministro

La entrega se gestionó como laboratorio: configurar según métodos de laboratorio y volumen de muestras. La ejecución se centró en selección por método, volumen de muestras y kit de reactivos, junto con certificación Ex y trazabilidad de datos según GMP.

Resultados en campo

La operación evidencia el beneficio: métodos normalizados que hacen comparables los datos entre laboratorios, con una confianza claramente mayor en este punto de medición.

Energía y Electricidad

Energía y Electricidad — Hach-Lab: caso de aplicación

Perfil del cliente

El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hach-Lab; el foco es análisis de agua colorimétrico y volumétrico en laboratorio.

Dificultades clave

Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por método, volumen de muestras y kit de reactivos.

Implementación

El alcance se canalizó por la vía de laboratorio: configurar según métodos de laboratorio y volumen de muestras. Técnicamente se apoya en selección por método, volumen de muestras y kit de reactivos, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.

Beneficio para el cliente

En la práctica esto significa métodos normalizados que hacen comparables los datos entre laboratorios, lo que redujo la carga del equipo de mantenimiento.