DR4900 Laboratory Spectrophotometer for water analysis

DR4900 Laboratory Spectrophotometer for water analysis
DR4900 Laboratory Spectrophotometer for water analysis
HACH DR4900-US
Configurable Models 2 models
DR4900 Laboratory Spectrophotometer for water analysis

产品概述

Bringing Effortless Accuracy to Your Lab

Built on the trusted legacy of the DR3900, the DR4900 Spectrophotometer increases analytical reliability and strengthens your laboratory’s operational performance. Engineered for routine and high‑throughput water analysis, the instrument combines stable optics, automated verification functions, and streamlined workflows to deliver consistent, traceable results across a wide range of parameters. Accurate, reproducible data is fundamental for laboratory oversight. The DR4900 reduces sources of analytical variability by integrating diagnostic controls, guided workflows, and an interface designed to standardize testing steps. The result is fewer repeat analyses, reduced operator‑dependent variation, and better confidence in day‑to‑day results. The DR4900 Lab Spectrophotometer with a built-in workflow camera features barcode-based TNTplus vial recognition. The system automatically identifies the correct method for each vial, minimizing manual errors and ensuring compliance and method traceability. Technical Innovations That Protect Data Integrity 10-inch High‑Resolution Touchscreen The large, full‑color display enables rapid navigation of analytical steps, clear visualization of spectral data, and fast review of sample information. The modern UI is optimized for multi‑operator labs, reducing training time and minimizing navigation errors. Integrated Turbidity Diagnostics Optical monitoring verifies whether sample turbidity may interfere with TNTplus vial measurements. The system alerts the operator when filtration or additional sample preparation is recommended, helping maintain result accuracy in samples with suspended solids. Temperature Monitoring for Vial Tests An integrated temperature sensor evaluates vial temperature prior to measurement. This helps ensure that exothermic reactions or insufficient equilibration times do not impact analytical output, particularly important for temperature‑sensitive colorimetric methods. With more than 250 pre‑programmed Hach methods, including a broad range of regulatory‑relevant parameters, the DR4900 supports standardized workflows and consistent method execution. Its robust optical design and built‑in diagnostics help maintain instrument performance over time, giving you greater oversight and control over daily testing operations. Trust the DR4900 Lab Spectrophotometerto deliver reliable, repeatable water quality data while improving analytical efficiency across your laboratory.

主要特点

  • Proven Technology, Modern Interface:The DR4900 Spectrophotometer maintains the trusted core of the DR3900, now enhanced with a 10” screen and modern user interface that helps reduce training time and speed up routine workflows. It’s the familiar performance lab professionals trust—elevated for modern needs.
  • Ensuring Reliable Results with Unrivaled Diagnostic Features:Temperature and turbidity diagnostics help prevent common testing errors -- reducing rework and ensuring consistent accuracy. When using Hach TNTplus vial chemistries, the DR4900 automatically checks the temperature and turbidity of your test, providing you with alerts when out of range, giving you the confidence you need in every measurement.
  • Complete Confidence - From Start to Finish:DR4900 users benefit from end-to-end expertise across instruments, chemistries, and service. So you get faster resolutions, deeper insights, and consistent results from a single partner.
  • DR4900 options to fit your workflow:Two versions of the DR4900 are available: one without an external camera (LPV451.99.00021) or with an external camera (LPV451.99.00121) to enable Smart Workflow features including Certificate of Analysis QR code scanning and Sample ID Text Recognition. • Without Camera (LPV451.99.00021) Delivers the full DR4900 analytical performance and error prevention features for routine lab workflows • With Camera (LPV451.99.00121) Includes all DR4900 performance features plus an external camera that enables Smart Workflow capabilities such as Certificate of Analysis QR code scanning and Sample ID Text Recognition - reducing manual data entry and supporting documentation tracking directly at the instrument.

技术参数

参数名称说明
Accuracy±1.5 nm (340 - 900 nm)
Altitude2000 m maximum
CameraYes
CertificationsCE, UKCA, CMIM, FCC, ISED, certified to UL and CSA safety standards by TÜV
Data Logger> 10,000 measured values (measured values, date, time, sample ID, user ID)
Dimensions (H x W x D)226 mm x 255 mm x 344 mm
Display10 inch (25.4 cm)
Enclosure RatingIP20
Indoor/OutdoorIndoor
InterfacesUse only shielded cable with maximum length of 3 m (9.8 ft) for: USB type A and type C (front side) USB type A and type C (back side) Use only shielded cable (e.g., STP, FTP, S/FTP) with maximum length of 20 m (65.6 ft) for: 1x Ethernet
Light SourceHalogen lamp
Operating Conditions50 - 104 °F (10 - 40 °C ), maximum 80% relative humidity, non-condensing
Operating ModeTransmittance (%), absorbance (Abs) or concentration
Optical SystemReference beam, spectral
Over voltage categoryII
Photometric Accuracy5 mAbs at 0.0 - 0.5 Abs 1% at 0.50 - 2.0 Abs
Photometric Linearity< 0.5% - 2 Abs ≤ 1% at > 2 Abs with neutral glass at 546 nm
Photometric Measuring Range±3.0 Abs (340 - 900 nm)
Pollution Degree2
Power Requirements (Hz)50/60 Hz
Power Requirements (Voltage)100 - 240 VAC
Power SupplyBenchtop Power Supply
Preprogrammed Methods˃ 240
Protection ClassClass I
Sample Cell CompatibilityRectangular: 10 mm, 50 mm, 1 inch Round: 13 mm, 16 mm, 1 inch
Scanning Speed≥ 8 nm/s (in increments of 1 nm)
Spectral Bandwidth5 nm
Storage Conditions-40 - 140 °F (-40 - 60 °C), maximum 80% relative humidity, non-condensing
Stray Light< 0.1% T at 340 nm with NaNO₂
User Programs˃ 100 user programs
Warranty12 months
Warranty1
Wavelength Accuracy± 1.5 nm (wavelength range 320 - 900 nm)
Wavelength CalibrationAutomatic
Wavelength Range320 - 1100 nm
Wavelength Reproducibility± 0.1
Wavelength Resolution1
Wavelength SelectionAutomatic, based on the procedure selected
Weight4.8 kg (10.58 lb)
What's included?Spectrophotometer DR4900; adapter "A" for 1 inch round cell, 10 mm rectangular cell + Accuvac vials; sample cells (matched pair); light shield; dust cover; power cord with country-specific adapter plug; power adapter; camera; user manual

应用领域

Discharge · Groundwater · Influent for Wastewater · Municipal Water · Nutrient Monitoring · Potable Water · Production Water · QA/QC Lab · Regulations · Secondary Treatment · Surface Water · Water Reuse

同系列其他配置

型号
LPV451.99.00021DR4900 Laboratory Spectrophotometer, without camera

资料下载

2 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hach-lab — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.

Configuration

Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hach-lab — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.

What We Did

We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hach-lab — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.

Delivery Approach

Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hach-lab — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.

Implementation

The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.