产品概述
Reliable Monitoring for Critical Water Quality
Monitoring total hardness in water systems is essential for optimizing processes, protecting equipment, and ensuring compliance with industry standards. The EZ1016sc Total Hardness analyser provides accurate, real-time measurements to help you achieve these goals. With advanced features and a user-friendly design, this analyser simplifies water hardness monitoring, offering reliable performance tailored to your operational needs. Key Features Flexible Customisation The EZ1016sc Total Hardness analyser is built to effortlessly adapt to a wide range of operational needs. It offers monitoring capabilities for up to 8 streams and provides versatile output options, ranging from standard 4x mA to advanced 8x mA configurations. The analyser easily integrates with common industrial communication protocols such as Modbus RTU, Modbus TCP/IP, Profinet, Profibus DP, and Ethernet/IP, ensuring smooth system compatibility and optimised process control. Reliable and Easy to Use Engineered for long-lasting reliability, the EZ1016sc Total Hardness analyser delivers consistent performance in even the toughest industrial environments. Its intuitive interface minimises the learning curve, allowing operators to focus on essential tasks without extensive training. With its robust design, the analyser ensures precise data with minimal maintenance, providing the dependable results you need to reduce downtime. Explore Tailored Solutions Take control of total hardness monitoring with the EZ1016sc Total Hardness analyser. Contact us today to learn how this innovative solution can optimise your processes, protect your equipment, and support compliance with regulatory and industry requirements.
主要特点
- Performance in Challenging Environments:Designed to excel in tough conditions, the system features preconditioning solutions, including self-cleaning filtration panels that seamlessly integrate with EZ sc analyzers. These prefiltration panels ensure reliable, long-term performance while minimizing maintenance needs, making them ideal for demanding applications.
- Cost-Effective and Scalable Monitoring:With support for up to 8 streams, the EZ1016sc reduces per-sampling-point costs while delivering comprehensive insights. Its flexible, scalable design adapts to your evolving monitoring needs, from basic to complex analyses.
- Enhanced Operational Efficiency with Advanced Connectivity:Real-time data and advanced connectivity improve reaction times, enabling faster, more informed decisions. Integrate the EZ1016sc with your systems using configurable analogue or digital outputs for optimized performance.
技术参数
| 参数名称 | 说明 |
|---|---|
| Ambient Temperature | 50 - 86°F (10 - 30 °C) ± 4 °C deviation at 5 - 95% relative humidity (non-condensing) |
| Analog Outputs | Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard: 4, optional: 8 |
| Automatic cleaning | Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly |
| Calibration | Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced |
| Certifications | CE, ETL certified to UL and CSA safety standards, UKCA |
| Cycle Time | No Dilution Default: 10 min. Continuous: 7 min. Internal Dilution Default: 15 min. Continuous: 10 min. |
| Demineralized Water | Internal dilution option: Rinse water & Dilution water |
| Digital Outputs | Profibus DP or Modbus RTU |
| Dimensions (H x W x D) | 740 mm x 500 mm x 340 mm |
| Drain | Atmospheric pressure, vented, min. Ø 32 mm |
| Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm² |
| Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar |
| Interferences | Some metal ions interfere by causing fading or indistinct end points or by stoichiometric consumption of EDTA. Suspended or colloidal organic matter can interfere with the end point. Large quantities of color and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere. |
| Lower Limit of Detection (LOD) | No Dilution 0.025 - 0.25 mg/L CaCO₃: 0.025 mg/L 0.025 - 0.5 mg/L CaCO₃: 0.025 mg/L 0.05 - 1 mg/L CaCO₃: 0.05 mg/L Internal Dilution 0.25 - 5 mg/L CaCO₃: 0.25 mg/L 0.5 - 10 mg/L CaCO₃: 0.5 mg/L 1.25 - 25 mg/L CaCO₃: 1.25 mg/L 2.5 - 50 mg/L CaCO₃: 2.5 mg/L 3.75 - 75 mg/L CaCO₃: 3.75 mg/L 5 - 100 mg/L CaCO₃: 5 mg/L |
| Material | Hinged part: Thermoform ABS, door: PMMA Wall section: Galvanized steel, powder coated |
| Measurement method | Calmagite colorimetric method |
| Measurement Method | Colorimetric |
| Number of sample streams | Standard: 1 Optional accessory for 2, 4, or 8 sample streams |
| Outputs | Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP |
| Parameter | Hardness, total |
| Power | 100 - 240 VAC, 50/60 Hz Max. power consumption: 120 VA |
| Precision | Better than 3% of full scale at: 0.025 - 0.25 mg/L CaCO₃ 0.025 - 0.5 mg/L CaCO₃; and better than 2% of full scale for standard test solutions. |
| Protection Class | IP44 |
| Range | No Dilution 0.025 - 0.25 mg/L CaCO₃ 0.025 - 0.5 mg/L CaCO₃ 0.05 - 1 mg/L CaCO₃ Internal Dilution 0.25 - 5 mg/L CaCO₃ 0.5 - 10 mg/L CaCO₃ 1.25 - 25 mg/L CaCO₃ 2.5 - 50 mg/L CaCO₃ 3.75 - 75 mg/L CaCO₃ 5.0 - 100 mg/L CaCO₃ |
| Reagent Requirements | Keep between 50 - 86 °F (10 - 30 °C) |
| Relays | 5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150) |
| Sample Flow Rate | 100 - 300 mL/min |
| Sample Pressure | By external overflow vessel (open to atmospheric pressure) |
| Sample Quality | Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU |
| Sample Temperature | 50 - 86 °F (10 - 30 °C) |
| Validation | Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly |
| Warranty | 12 months |
| Weight | Max. 77 lb (35 kg) |
| What's included? | EZ1016 Hardness Analyzer, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 4 x empty 2.5L Reagent Containers with Fittings (for Color, Acid, Buffer and EDTA Solution) |
应用领域
Municipal Water
同系列其他配置
| 型号 | |
|---|---|
| EZ1012.9700140T | EZ1012sc Cyanide Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1035.9700140T | EZ1035sc Silica Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1036.9700140T | EZ1036sc Sulfate Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1037.9700140T | EZ1037sc Sulfide Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ3005.9700140T | EZ3005sc Chloride Ion-Selective Electrode (ISE) Analyzer, 1 stream, 4x |
| EZ3008.9700140T | EZ3008sc Fluoride Ion-Selective Electrode (ISE) Analyzer, 1 stream, 4x |
| EZ3505.9700140T | EZ3505sc Chloride Ion-Selective Electrode (ISE) Standard Addition Anal |
| EZ3508.9700140T | EZ3508sc Fluoride Ion-Selective Electrode (ISE) Standard Addition Anal |
| EZ1017.9700140T | EZ1017sc Hardness, calcium Colorimetric Analyzer, 1 stream, 4x mA Outp |
资料下载
- Maximum Insight with Minimal Effort : EZ sc verses EZ
- 최소한의 노력으로 최대의 효과 : EZ sc ~에 비해 EZ
- Máxima perceção com o mínimo de esforço : EZ sc em comparação com EZ
- Analisadores Online Série EZ
- Maximální přehled s minimálním úsilím : EZ sc vs. EZ
- Online analyzátory řady EZ
- Analyzer Seri EZ Online Solusi Lengkap
- Brochure EZ Series Online Analysers
Recomendados similares
HACHSC1000 relay module for DIN-rail mounting, 4 Relays, max. 240V
HACHNP6000sc Phosphate Analyzers
Stainless Steel Chain Mount Kit
Mercury Thermometer, Celsius, -10 to 200°C
Mercury Thermometer, Fahrenheit, -30 to 120°F
COVER-SERVICE REPLACEMENT
HACHBattery cable, SD900
HACH