产品概述
Experience the power of redundancy.
At times, depending on the difficulty of flow monitoring site applications or conditions, as well as in overflow monitoring or billing scenarios, more than one level measurement is desired to guarantee accuracy. That’s where the Hach Redundant-Level Monitoring System comes into play. This system combines a Hach FL900 Series Flow Logger with AV9000 Analyzer Module, a Hach Submerged AV Sensor, and a Hach US9003 In-Pipe Ultrasonic Sensor to create a highly accurate level monitoring solution. In this configuration, level is captured by both a pressure transducer in the Sub AV sensor and with ultrasonic technology in the in-pipe sensor, dramatically limiting your risk of missing data.
主要特点
- Redundant-Level Monitoring System:Often more than one level measurement is desired due to the application or site conditions. The Hach redundant-level system provides this capability and includes an FL902 flow logger, an AV9000 with a Hach submerged area velocity sensor, and an US9003 in-pipe ultrasonic level sensor. In this configuration, the pressure transducer in the submerged area velocity sensor and the in-pipe ultrasonic sensor measure level and either or both can be used to calculate flow. Redundancy is often desired to insure accurate level measurement in critical situations such as overflow monitoring or billing.
- Plug-and-Play Sensors with FL900 Series Flow Loggers:Get started with the FL902 and create a flexible flow meter network using FL900 series loggers and plug-and-play flow sensors. Three velocity sensor technologies and two level sensor technologies are available along with both noncontact and submerged options. The FL902 used for the redundant-level system has two sensor ports and can be deployed for future projects with different sensor combinations to match the application.
- Easy Installation Decreases Site Time and Increases Crew Efficiency:For typical redundant-level monitoring applications, the submerged AV sensor and in-pipe ultrasonic sensor are installed on a single mounting band with the submerged AV sensor at the base of the pipe and the ultrasonic sensor at the crown of the pipe. For confidence in the installation, both sensors provide real time measurements and the in-pipe ultrasonic sensor includes a status LED that indicates proper installation and operation. With the time-saving features designed into the system, crews spend less time on site, increasing the effciency of flow monitoring crews.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | FL900: Timebase Accuracy: +/- 0.002 % , synchronized every 24 hours with server software and modem |
| Alarm | Maximum of 16 channel alarms including high/high, high, low, low/low and system alarms including low battery, low RTC battery, low slate memory, slate memory full, sensor timeout, sensor ID error |
| Alternate KTO? | No |
| Battery Life | Varies with sensor type, logging intervals, telemetry and environment. |
| Certifications | Logger: CE; optional AC power supply: UL/CSA/CE |
| Communication | USB RS232 (Baud rates: 9600, 19200, 38400, 57600, 115200) |
| Communication (optional) | Remote Communications (optional): Wireless modem: 3G & 4G LTE |
| Data Storage | Datalog: 325,000 sensor measurement data points; 1128 days for 3 channels at 15-minute log intervals Event Log: 1,000 events maximum in non-volatile flash memory Sample History: 2,000 sample events maximum in non-volatile flash memory |
| Data Storage 2 | Sample History: 2000 sample events maximum in non-volatile flash memory |
| Data Storage 3 | Datalog: 325 k data points, 1128 days for 3 channels at 15-minute log intervals |
| Datalog Channels | 16 maximum |
| Environmental Rating | NEMA 6P (IP68) |
| Level Accuracy | US9003: 0.2 mm/25.4 mm (0.008 in./in.) from the calibration point at steady state temperature, still air and ideal target |
| Level Measurement Method | US9003: Down-looking ultrasonic Sub AV: Differential pressure |
| Level Range | 0 to 10 ft range |
| Logging | 1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 or 60 minutes Primary and secondary intervals for dynamic logging. |
| Manual Languages | English |
| Modem | Non-Wireless |
| Operating Temperature Range | -18 to 60ºC (0 to 140ºF) at 95% RH |
| Power Requirements (Voltage) | 8 - 18 V DC |
| Pre-configuration? | AV9000 Module, SUB AV 30ft and US9003 Ultrasonic Sensor |
| Protocol | Local Modbus RTU |
| Recommended Range | US9003: 0 to 382.91 cm (0.00 to 150.75 in.) |
| Sensor Connector | 2, with US9003 AV9000 & SUB AV |
| Sensor Connectors | 2, additional options |
| Sensor Ports | 2 |
| Sensors Included | Sub AV & Ultrasonic |
| Storage Conditions | -40 to 60ºC (-40 to 140ºF) |
| Supported Sensors | FLO-TOTE 3, FLO-DAR, FLO-DAR with Surcharge Velocity Sensor (SVS), Submerged Area Velocity Sensor (requires AV9000 Analyzer Module), Rain Gauge, Sigma 950 Flow Meter (requires IM9001), US9001, US9002 |
| Typical Minimum Operating Depth | Sub AV: 2 cm (0.8cm) |
| Velocity Accuracy | ±2% of reading or 0.05 fps** **Uniform velocity profile, known salinity, positive flow. Field performance is site specific. |
| Velocity Measurement Method | Doppler ultrasonic; twin 1 MHz piezoelectric crystals |
| Velocity-Induced Depth Error | Compensated based on flow velocity |
| Warranty | 12 months |
| What's included? | The Hach redundant-level flow monitoring system components include the area velocity sensor, in-pipe ultrasonic sensor and the FL902 Flow Logger. |
同系列其他配置
| 型号 | |
|---|---|
| FL900AV.97 | FL900 Logger with AV9000 Analyzer Module |
资料下载
- Open Flow Measurement Trends
- Submerged Area Velocity Flow Meter
- FL900 Series Flow Logger
- Hach AV9000 Area Velocity Analyzer Module
- US9000 Ultrasonic Sensor Series: Flow Monitoring & Level Alarming
- Full User Manual: FL900 Series Flow Logger
- Manuel d'utilisation: Enregistreur d'écoulement série FL900
- User Manual: FSDATA Desktop Instrument Manager
Recomendados similares
HACHSC1000 relay module for DIN-rail mounting, 4 Relays, max. 240V
HACHNP6000sc Phosphate Analyzers
Stainless Steel Chain Mount Kit
Mercury Thermometer, Celsius, -10 to 200°C
Mercury Thermometer, Fahrenheit, -30 to 120°F
Accu4 Spare Chamber with Plumbing, High Pressure
HACH