Orbisphere 312xx Hydrogen Sensors
Orbisphere 312xx Hydrogen Sensors
产品概述
Allows you to monitor hydrogen in the power production process.
Standard Hydrogen TC sensor with external temperature sensor adaptor with nitrogen purge and protection cap. Sensor Cable to be ordered: 32505.03. External Temperature sensor to be ordered: 32557/32559 Maximum pressure: 20 bar
主要特点
- Patented thermal conductivity (TC) sensor design:
- Selective and precise measurement of hydrogen in gaseous or liquid samples:
- No specific sample preparation required, the gas concentration is measured directly in the sample:
- Rugged construction can handle harsh plant conditions and high sample pressures:
- Flexibility of installation for better process control and very low maintenance:
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | (Sample temp. 20 - 50°C within ± 5°C of calibration temperature) The greater of Membrane 29561A: ±1% of reading, or ±2 ppb, or ±0.03 cc/kg, or ±1.5 bar Membrane 2952A: ±1% of reading, or ±8 ppb, or ±0.1 cc/kg, or ±6 mbar Membrane 2935A: ±1% of reading, or ±25 ppb, or ±0.4 cc/kg, or ±20 mbar |
| Accuracy 2 | (Sample temp. 0 - 50°C independent of calibration temperature) The greater of Membrane 2952A: ±3% of reading, or ±60 ppb, or ±0.6 cc/kg, or ±20 mbar Membrane 2935A: ±3% of reading, or ±150 ppb, or ±2.5 cc/kg, or ±50 mbar |
| Application | Power |
| Certifications | 2004/108/EC - EN 61326-1 |
| Cycle Time | 17 s |
| Flow Rate | Typical Flow Rate Membrane 29561A: 220 mL/min Membrane 2952A: 200 mL/min Membrane 2935A: 100 mL/min |
| Parameter | Hydrogen (H₂) |
| Protection Class | IP65 |
| Purge connection | Nitrogen Purge |
| Radiation Resistance Level | Membrane 29561A: 105 rad Membrane 2952A: 108 rad Membrane 2935A: 108 rad |
| Range | Range at 25 °C Membrane 29561A: 0 - 2 ppm, or 0 - 25 cc/kg, or 0 - 1.5 bar Membrane 2952A: 0 - 10 ppm, or 0 - 120 cc/kg, or 0 - 6 bar Membrane 2935A: 0 - 20 ppm, or 0 - 220 cc/kg, or 0 - 12 bar |
| Response Time | 17 s |
| Sample Pressure | 0 - 20 bar |
| Sample Temperature | 0 - 50 °C (32 - 122 °F) |
| Temperature Range | -5 - 50 °C |
| Warranty | 6 months |
| Weight | 0.95 kg |
| What's included? | Sensor only. Controller, sensor cable, flow-chamber or process connection must be ordered separately. |
应用领域
Ultrapure Water
同系列其他配置
| 型号 | |
|---|---|
| 31230.01 | Orbisphere Hydrogen (H₂) EC Sensor in stainless steel with EPDM O-rin |
| 31292HP | Orbisphere Hydrogen (H₂) TC Sensor with carbon dioxide purge, protecti |
| 31292TC | Orbisphere Hydrogen (H₂) TC Sensor with carbon dioxide purge, protecti |
| 31290HP | Orbisphere High Pressure Hydrogen (H₂) TC sensor with nitrogen purge, |
资料下载
- ORBISPHERE and Hydrogen Measurement for Stator Coolant; Hydrogen Measurement in Hydrogen-Cooled Turbo Generators
- Dissolved Oxygen and Hydrogen Analysis in Reactor Coolant Systems: Orbisphere 510 with Channel Compensation
- Analysis Of Waste-Gas / Off-Gas Oxygen and Hydrogen in Nuclear Power Plants
- Introduction to Hach Services
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- Orbisphere Hydrogen Sensors
- 511FK, K1200, 31290 Dissolved Oxygen and Hydrogen in nuclear applications CSI Specifications
Recomendados similares
HACHSC1000 relay module for DIN-rail mounting, 4 Relays, max. 240V
Ver →
HACHNP6000sc Phosphate Analyzers
Ver →
A
HACHStainless Steel Chain Mount Kit
Ver →
A
HACHMercury Thermometer, Celsius, -10 to 200°C
Ver →
A
HACHMercury Thermometer, Fahrenheit, -30 to 120°F
Ver →
A
HACHCPVC Insertion Mounting Hardware 2", pHD Series
Ver →
A
HACHCOVER-SERVICE REPLACEMENT
Ver →
HACHBattery cable, SD900
Ver →