产品概述
Allows you to monitor hydrogen in the power production process.
The patented polarographic sensor design is a proven performer wherever knowledge of H2 content is critical. From corrosion monitoring in power generators to chemical manufacturing, this sensor provides fast, accurate hydrogen measurements, in gaseous or liquid samples.
A wide range of temperature and pressure ranges is made possible by the exclusive valve seat sealing, whereby the sensor cathode is mechanically tensioned against a ceramic valve seat to ensure the integrity of the seal. This design enables a vanishingly small residual signal, for improved accuracy.
All these hydrogen sensors use the deep-draw membrane mounting method for a uniformly thin layer of electrolyte for faster response and superior stability. Coupled with a screw-on protection cap, the sensor provides in-service intervals of up to a year.
主要特点
- Guard Ring Electrode Design:An auxiliary guard ring electrode surrounds the working electrode to shield against the influence of other gases and improve stability.
- Rugged Construction:Use for harsh chemicals, hot CIP and high pressure situations.
- Flexibility:Installs in-line for process control, or in flow chamber for spot measurement. Cable detaches at sensor end for installation and maintenance flexibility.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | The greater of ±1% of reading, or ±0.03 ppb, or ±1 Pa (Membrane 2956A) |
| Accuracy 2 | The greater of ±1% of reading, or ±0.09 ppb, or ±6 Pa (Membrane 2952A) |
| Accuracy 3 | The greater of ±1% of reading, or ±1 ppb, or ±50 Pa (Membrane 2995A) |
| Accuracy 4 | The greater of ±1% of reading, or ±10 ppb, or ±1 kPa (Membrane 29015A) |
| Ambient Temperature | -5 - 100 °C (23 - 212 °F) |
| Application | Corrosion rate |
| Certifications | IP68 / NEMA4 |
| Flow Rate | Typical Flow Rate Membrane 2956A: 50 - 220 mL/min Membrane 2952A: 40 - 200 mL/min Membrane 2995A: 20 - 70 mL/min Membrane 29015A: 20 - 40 mL/min |
| Protection Class | IP68 / NEMA4 |
| Radiation Resistance Level | Membrane 2956A: 2x104 rad Membrane 2952A: 108 rad Membrane 2995A: 108 rad Membrane 29015A: N/A |
| Range | Range at 25 °C Membrane 2956A: 0 - 75 ppb or 0 Pa - 5 kPa Membrane 2952A: 0 - 300 ppb or 0 Pa - 20 kPa Membrane 2995A: 0 - 3200 ppb or 0 Pa - 200 kPa Membrane 29015A: 0 ppb - 32 ppm or 0 - 2000 kPa |
| Sample Pressure | 0 - 100 bar |
| Temperature Range | Accurate from -5 - 50 °C (23 - 122 °F) Resistant - temperature from -5 - 100 °C (23 - 212 °F) |
| Warranty | 6 months |
| Weight | 140 - 700 g, depending on the construction material |
| What's included? | Sensor only. Controller, sensor cable, flow-chamber or process connection must be ordered separately. |
同系列其他配置
| 型号 | |
|---|---|
| 31292HP | Orbisphere Hydrogen (H₂) TC Sensor with carbon dioxide purge, protecti |
| 31292TC | Orbisphere Hydrogen (H₂) TC Sensor with carbon dioxide purge, protecti |
| 31290TC | Orbisphere Hydrogen (H₂) TC Sensor with nitrogen purge, protection cap |
| 31290HP | Orbisphere High Pressure Hydrogen (H₂) TC sensor with nitrogen purge, |
资料下载
- Measurement of Dissolved Hydrogen as a Determination of Corrosion Rate in Power Plants
- Introduction to Hach Services
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- Power Industry Laboratory & Process Analysis (JP)
- ORBISPHERE Laboratories Technical Notes (JP)
- 有機溶媒用 溶存酸素計(DO計)
- Orbisphere Hydrogen Sensors
Recomendados similares
HACHSC1000 relay module for DIN-rail mounting, 4 Relays, max. 240V
HACHNP6000sc Phosphate Analyzers
Stainless Steel Chain Mount Kit
Mercury Thermometer, Celsius, -10 to 200°C
Mercury Thermometer, Fahrenheit, -30 to 120°F
Accu4 Spare Chamber with Plumbing, High Pressure
HACH