HI5522 is an advanced research-grade benchtop pH/mV/ISE/EC/TDS/Salinity/Resistivity meter that can be fully customized via a large color LCD, capacitive touch keys, and a USB port for computer connection. HI5522 features a wealth of functions, including ISE incremental methods, data logging, alarm limits, comprehensive GLP, etc., while retaining the simple use of dedicated keys for routine operation and virtual keys that guide the user through setup options. HI5522 ensures the credibility of pH measurement through the exclusive Hanna Instruments CAL Check™ function, which alerts the user to potential problems during calibration, including whether the buffer has been contaminated or whether the probe needs cleaning.

  • Capacitive touch keypad

  • Two independent channels

  • Selection of ISE concentration devices and incremental methods

SKU HI5522-02
Product Name Laboratory Research Grade Benchtop pH/mV/ISE and EC/TDS/Salinity/Resistivity Meter - HI5522
Quote Required Yes
pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH
pH Resolution 0.1 pH / 0.01 pH / 0.001 pH
pH Accuracy ±0.1 pH / ±0.01 pH / ±0.002 pH ± 1LSD
pH Calibration Up to five-point calibration, eight standard buffers available (pH 1.68, 3.00, 4.01, 6.86, 7.01,9.18, 10.01, 12.45), and five custom buffers
pH Temperature Compensation automatic or manual from -20.0 to 120.0 °C
mV Range ±2000.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV ± 1LSD
mV Relative Offset ±2000.0 mV
ISE Range e.g. 10-7 to 10M/ 0.005 to 105 ppm/ 5·10–7 to 5·107 conc
ISE Resolution 1 conc./ 0.1 conc. / 0.01 conc. / 0.001 conc
ISE Accuracy ±0.5% (monovalent ions); ±1% (divalent ions)
ISE Calibration Up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five custom solutions
EC Range 0.000 to 9.999 μS/cm, 10.00 to 99.99 μS/cm, 100.0 to 999.9 μS/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm actual EC*
EC Resolution 0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy ±1% of reading (±0.01 μS/cm)
EC Calibration automatic standard recognition (0.000 μS/cm, 84.00 μS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm) or user standard; single point or multi-point calibration
TDS Range 0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt actual TDS* (with 1.00 factor)
TDS Resolution 0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt
TDS Accuracy ±1% of reading (±0.01 ppm)
EC/TDS Temperature Compensation Disabled / Linear / Non linear (natural water)
Temperature Correction Coefficient 0.00 to 10.00 %/°C
Reference Temperature 5.0 °C to 30.0 °C
Cell Constant 0.0500 to 200.00
Cell Type 4 cells
Salinity (% NaCl) Range 0.0 to 400.0%
Salinity (% NaCl) Resolution 0.01%
Salinity (% NaCl) Accuracy ±1% of reading
Salinity (PSU) Range 0.00 to 42.00 psu
Salinity (PSU) Resolution 0.01
Salinity (PSU) Accuracy ±1% of reading
Salinity (PSU) Calibration one-point (with HI7037 standard)
Salinity Range 0.00 to 80.00 ppt
Salinity Resolution (ppt) 0.01
Salinity Accuracy (ppt) ±1% of reading
Resistivity Range 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resistivity Resolution 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*
Resistivity Accuracy ±2% of reading (±1 Ω•cm)
Temperature Range -20.0 to 120.0 ºC**; -4.0 to 248.0 ºF**; 253.15 to 393.15 K**
Temperature Resolution 0.1 °C, 0.1 °F, 0.1 K
Temperature Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K (without probe)
Input Channels 2 (pH/mV/ISE; Conductivity/Resistivity/TDS/ Salinity)
pH Electrode HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)
EC/TDS Probe HI76312 platinum, four-ring EC/TDS probe with and 1 m (3.3’) cable (included)
Temperature Probe HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)
Logging Type Automatic, Manual, AutoHold
Logging Memory Up to 100 lots, 50,000 records max/lot; maximum 100,000 data points / channel
Logging Interval 14 selectable between 1 second and 180 minutes
Connectivity Opto-isolated USB
GLP yes (GLP Channel 1
Calibration Timeout Reminder yes
USP Compliant USP <645> Application
Profiles Up to 10 (5 for each)
Display Color Graphic LCD 240 x 320 pixels, 8 keys capacitive touch keyboard
Power Supply 12 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing
Dimensions 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”)
Weight 1.2 Kg (2.6 lbs)
Ordering Information HI5522 is supplied with HI1131 pH electrode, HI7662-T temperature probe, HI76312 conductivity probe, HI76404W electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), 12 VDC power adapter and instructions.
Notes *Uncompensated conductivity (or TDS) is the conductivity (or TDS) value without temperature compensation.
Tratamiento de Aguas Residuales Municipales

Tratamiento de Aguas Residuales Municipales — Hanna: caso de configuración desde stock

Resumen del proyecto

La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hanna en la planta existente, con el objetivo de análisis portátil y de laboratorio con instrumentos Hanna.

Retos técnicos

Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hanna deba incluir selección por parámetros, precisión y portabilidad.

Configuración

El suministro y la instalación se organizaron por la vía de stock: configurar desde stock y entregado con rapidez. En planta esto supuso selección por parámetros, precisión y portabilidad; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.

Comportamiento

Tras la puesta en marcha el resultado es resultados in situ, con menos verificaciones de laboratorio, y las lecturas se usan ya para ajustar el proceso.

Alimentación y Bebidas

Alimentación y Bebidas — Hanna: caso de configuración desde stock

Situación en planta

Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis portátil y de laboratorio con instrumentos Hanna.

El problema

La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por parámetros, precisión y portabilidad.

Qué hicimos

Adoptamos un enfoque de stock: configurar desde stock y entregado con rapidez. La entrega se construyó en torno a selección por parámetros, precisión y portabilidad; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.

Resultado operativo

En servicio el sistema responde a lo previsto: resultados in situ, con menos verificaciones de laboratorio, con un mantenimiento rutinario notablemente menor.

Química y Farmacéutica

Química y Farmacéutica — Hanna: caso de configuración desde stock

Contexto de aplicación

reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hanna, centrándose en análisis portátil y de laboratorio con instrumentos Hanna.

Limitaciones del proceso

la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hanna debe cubrir selección por parámetros, precisión y portabilidad.

Enfoque de suministro

La entrega se gestionó como stock: configurar desde stock y entregado con rapidez. La ejecución se centró en selección por parámetros, precisión y portabilidad, junto con certificación Ex y trazabilidad de datos según GMP.

Resultados en campo

La operación evidencia el beneficio: resultados in situ, con menos verificaciones de laboratorio, con una confianza claramente mayor en este punto de medición.

Energía y Electricidad

Energía y Electricidad — Hanna: caso de configuración desde stock

Perfil del cliente

El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hanna; el foco es análisis portátil y de laboratorio con instrumentos Hanna.

Dificultades clave

Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por parámetros, precisión y portabilidad.

Implementación

El alcance se canalizó por la vía de stock: configurar desde stock y entregado con rapidez. Técnicamente se apoya en selección por parámetros, precisión y portabilidad, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.

Beneficio para el cliente

En la práctica esto significa resultados in situ, con menos verificaciones de laboratorio, lo que redujo la carga del equipo de mantenimiento.