HI5522-02

HI5522-02

Research grade benchtop multiparameter water quality analyzer

HANNA Instruments HI5522-02
Laboratory research grade benchtop pH/mV/ISE and EC/TDS//salinity/resistivity meter

Product Overview

HI5522 is an advanced research-grade benchtop pH/mV/ISE/EC/TDS/Salinity/Resistivity meter that can be fully customized via a large color LCD, capacitive touch keys, and a USB port for computer connection. HI5522 features a wealth of functions, including ISE incremental methods, data logging, alarm limits, comprehensive GLP, etc., while retaining the simple use of dedicated keys for routine operation and virtual keys that guide the user through setup options. HI5522 ensures the credibility of pH measurement through the exclusive Hanna Instruments CAL Check™ function, which alerts the user to potential problems during calibration, including whether the buffer has been contaminated or whether the probe needs cleaning.

  • Capacitive touch keypad

  • Two independent channels

  • Selection of ISE concentration devices and incremental methods

SKU HI5522-02
Product Name Laboratory Research Grade Benchtop pH/mV/ISE and EC/TDS/Salinity/Resistivity Meter - HI5522
Quote Required Yes
pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH
pH Resolution 0.1 pH / 0.01 pH / 0.001 pH
pH Accuracy ±0.1 pH / ±0.01 pH / ±0.002 pH ± 1LSD
pH Calibration Up to five-point calibration, eight standard buffers available (pH 1.68, 3.00, 4.01, 6.86, 7.01,9.18, 10.01, 12.45), and five custom buffers
pH Temperature Compensation automatic or manual from -20.0 to 120.0 °C
mV Range ±2000.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV ± 1LSD
mV Relative Offset ±2000.0 mV
ISE Range e.g. 10-7 to 10M/ 0.005 to 105 ppm/ 5·10–7 to 5·107 conc
ISE Resolution 1 conc./ 0.1 conc. / 0.01 conc. / 0.001 conc
ISE Accuracy ±0.5% (monovalent ions); ±1% (divalent ions)
ISE Calibration Up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five custom solutions
EC Range 0.000 to 9.999 μS/cm, 10.00 to 99.99 μS/cm, 100.0 to 999.9 μS/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm actual EC*
EC Resolution 0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy ±1% of reading (±0.01 μS/cm)
EC Calibration automatic standard recognition (0.000 μS/cm, 84.00 μS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm) or user standard; single point or multi-point calibration
TDS Range 0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt actual TDS* (with 1.00 factor)
TDS Resolution 0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt
TDS Accuracy ±1% of reading (±0.01 ppm)
EC/TDS Temperature Compensation Disabled / Linear / Non linear (natural water)
Temperature Correction Coefficient 0.00 to 10.00 %/°C
Reference Temperature 5.0 °C to 30.0 °C
Cell Constant 0.0500 to 200.00
Cell Type 4 cells
Salinity (% NaCl) Range 0.0 to 400.0%
Salinity (% NaCl) Resolution 0.01%
Salinity (% NaCl) Accuracy ±1% of reading
Salinity (PSU) Range 0.00 to 42.00 psu
Salinity (PSU) Resolution 0.01
Salinity (PSU) Accuracy ±1% of reading
Salinity (PSU) Calibration one-point (with HI7037 standard)
Salinity Range 0.00 to 80.00 ppt
Salinity Resolution (ppt) 0.01
Salinity Accuracy (ppt) ±1% of reading
Resistivity Range 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resistivity Resolution 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*
Resistivity Accuracy ±2% of reading (±1 Ω•cm)
Temperature Range -20.0 to 120.0 ºC**; -4.0 to 248.0 ºF**; 253.15 to 393.15 K**
Temperature Resolution 0.1 °C, 0.1 °F, 0.1 K
Temperature Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K (without probe)
Input Channels 2 (pH/mV/ISE; Conductivity/Resistivity/TDS/ Salinity)
pH Electrode HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)
EC/TDS Probe HI76312 platinum, four-ring EC/TDS probe with and 1 m (3.3’) cable (included)
Temperature Probe HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)
Logging Type Automatic, Manual, AutoHold
Logging Memory Up to 100 lots, 50,000 records max/lot; maximum 100,000 data points / channel
Logging Interval 14 selectable between 1 second and 180 minutes
Connectivity Opto-isolated USB
GLP yes (GLP Channel 1
Calibration Timeout Reminder yes
USP Compliant USP <645> Application
Profiles Up to 10 (5 for each)
Display Color Graphic LCD 240 x 320 pixels, 8 keys capacitive touch keyboard
Power Supply 12 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing
Dimensions 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”)
Weight 1.2 Kg (2.6 lbs)
Ordering Information HI5522 is supplied with HI1131 pH electrode, HI7662-T temperature probe, HI76312 conductivity probe, HI76404W electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), 12 VDC power adapter and instructions.
Notes *Uncompensated conductivity (or TDS) is the conductivity (or TDS) value without temperature compensation.
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.