技术参数
加入对比测量
| 测量原理 | 热式质量流量(插入式) |
| 测量变量 | 质量流量、温度、校正体积流量、体积流量、流速、热流量、能量流、密度 |
| 测量误差 | ±1.0 % o.r.(100…10 % 量程);±0.10 % o.f.s.(10…1 % 量程) |
| 重复性 | 流速 >1.0 m/s 时 ±0.25 % o.r. |
| 响应时间 | 通常 < 3 s(63 % 阶跃响应,双向) |
过程条件
| 最大过程压力 | 20 bar (290 psi) |
| 环境温度 | -40 … +60 ℃ (-40 … +140 ℉) |
| 储存温度 | -50 … +80 ℃ (-58 … +176 ℉) |
| 过程连接 | 插入式,DN 80…1500 (3…60") |
电气与通信
| 防护等级 | IP66/67, Type 4X(可选 IP68 Type 6P) |
认证
| SIL 认证 | SIL 2 |
附件 / 备件 55
共 55 项备件 · 点击收起
| 订货号 | 名称 / 说明 | |
|---|---|---|
| XPD0052- | ISEM 电子插件, t-mass 300/500Usage: t-mass 300/500 digital. Valid for approvals acc. feature 010. ISEM module V305-02. | 询价 |
| XPD0053- | ISEM 电子插件, t-mass 300Usage: t-mass 300 Valid for approvals acc. feature 010. ISEM module V305-01. | 询价 |
| XPD0037- | I/O模块Usage: Proline 300/500 | 询价 |
| XPD0038- | I/O模块Usage: Proline 300/500 | 询价 |
| XPD0031- | 显示模块Usage: Proline 300/500, DKX001. | 询价 |
| 71323007 | 电源组件Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment. | 查看详情 |
| 71323008 | 电源组件Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment. | 查看详情 |
| 71323009 | 电源组件Usage: Promag/Promass/Prosonic Flow/ t-mass/Teqwave MW 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment. | 查看详情 |
| 71185788 | T-DAT模块 | 查看详情 |
| 71323010 | 模块盒, 300/500, ExUsage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board. | 查看详情 |
| 71323011 | 模块盒, 300, Non-hazUsage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board. | 查看详情 |
| 71323005 | 带状电缆组件Usage: Promag/Promass 300/500, t-mass/Teqwave MW 300, transmitter housing. | 查看详情 |
| 71323073 | 接线端子组件Usage: transmitter housing Alu/hygienic, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol. | 查看详情 |
| 71327818 | 接线端子组件Usage: transmitter housing Alu/hygienic, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol. | 查看详情 |
| 71323075 | 接线端子组件Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus, Profinet APL, Modbus TCP APL. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol. | 查看详情 |
| 71327819 | 接线端子组件Usage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol. | 查看详情 |
| 71323079 | 接线端子组件Usage: transmitter housing Alu/cast, connection compartment with remote display DKX001. Consists of: 1x connection terminal 4-Pol. | 查看详情 |
| 71323016 | 盖组件Usage: Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 300, Prosonic Flow 500, transmitter housing Alu, Non-haz. Promag/Promass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110.7x3.53 HNBR. | 查看详情 |
| 71323017 | 盖组件Usage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF. | 查看详情 |
| 71323018 | 盖组件Usage: Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 300, transmitter housing Alu, Non-haz. Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 HNBR. | 查看详情 |
型号配置 / 参数对比
诊断代码
tmass i300(65 条)→数据摘自 Endress+Hauser 操作手册,含状态信号、可能原因与维修指导。
服务案例
市政污水处理 · 热式气体质量流量计应用案例
客户情况
市政污水处理行业的典型场景是城市污水处理厂的进水、生化与出水工段。本次测量对象为热式气体质量流量计,工作重点是:测量空气、燃气等气体的质量流量。
面临的难点
现场工况为污水中含固率高、含腐蚀性组分,昼夜水量波动大,加上出水指标波动、探头易被污泥与生物膜覆盖,常规配置很难长期胜任。方案需要按气体组分、温度与含尘量选插入式或管段式。
实施方式
方案由流量测量落地:按管径、介质与量程做流量计量方案。技术要点在于按气体组分、温度与含尘量选插入式或管段式,并确保符合:出水须稳定达到一级 A 标准并联网上传数据。
客户收益
实际效果上,直接输出质量流量,燃烧配比更精准,现场运维人员的工作负担随之下降。
食品饮料 · 热式气体质量流量计应用案例
项目背景
配料、杀菌、灌装与 CIP 清洗工段。本次项目围绕热式气体质量流量计展开,要解决的核心问题是:测量空气、燃气等气体的质量流量。
工况挑战
现场介质与工况的特点是介质多为糖浆、乳品与饮料等易结垢物料,卫生级要求高,而且清洗频繁,仪表必须耐受 CIP/SIP 高温碱洗。因此热式气体质量流量计不能照搬通用配置,按气体组分、温度与含尘量选插入式或管段式。
解决方案
阿仪科技技术团队按流量测量的方式推进:按管径、介质与量程做流量计量方案。配置上按气体组分、温度与含尘量选插入式或管段式,并同步对照:须满足食品安全与卫生级(3-A / EHEDG)要求。
实施效果
投运后系统运行稳定,实际效果是:直接输出质量流量,燃烧配比更精准。
化工制药 · 热式气体质量流量计应用案例
项目概况
项目现场在反应釜、计量罐与成品储罐区。客户希望在既有装置上完善热式气体质量流量计配置,核心诉求是测量空气、燃气等气体的质量流量。
技术难点
真正麻烦的是:介质腐蚀性强、常带溶剂与结晶,部分区域为爆炸性环境,并且强腐蚀与防爆双重约束,仪表寿命短、停机维护成本高。这些都要求热式气体质量流量计在配置时按气体组分、温度与含尘量选插入式或管段式。
配置方案
按流量测量组织供货与实施:按管径、介质与量程做流量计量方案。现场按气体组分、温度与含尘量选插入式或管段式,并逐条核对:需满足防爆认证与 GMP 数据可追溯要求。
投运表现
完成调试后,直接输出质量流量,燃烧配比更精准,测量数据可直接用于工艺调整与考核。
电力能源 · 热式气体质量流量计应用案例
现场工况
该客户属于电力能源行业,生产装置位于锅炉给水、汽机凝结水与脱硫脱硝系统。项目的主要任务就是测量空气、燃气等气体的质量流量。
需要解决的问题
难点在于高温高压,蒸汽与含盐水并存;与此同时高温高压下测量漂移,非计划停机代价极高。选型上必须按气体组分、温度与含尘量选插入式或管段式。
我们的做法
我们采用流量测量的交付思路 — 按管径、介质与量程做流量计量方案。实施时按气体组分、温度与含尘量选插入式或管段式,同时逐项校验:需满足电力行业规程与机组可用率指标。
运行结果
系统投运以来表现稳定,日常维护量明显减少 — 直接输出质量流量,燃烧配比更精准。