技术参数
加入对比温度计
| 测量原理 | |
| 特性 / 应用 | 公制样式探头用于环境温度测量无颈部 |
| 保护套管 | 无 (不 intended 至用途带保护套管) |
| 保护套管外径 / 芯子 | 20,0 mm (0,79'') |
| 保护套管材质 | 铝 |
| 工作温度范围 | PT 100: -50 °C ...100 °C (-58 °F …212 °F) |
| 最大过程压力(静压) | 在 20 °C: 1 bar (15 psi) |
| 测量精度 | 等级符合 IEC 60751 等级 B 符合 IEC 60751 |
| 一体化表头变送器 | 是 (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| 认证 | SIL (变送器仅) |
专门设计的铂电阻(RTD)温度计主要用于监测室温。头部装配变送器的设备可即装即用,与直接连线的传感器相比,增强了测量精确度和可靠性,可用于室内外的环境温度测量。
优势
模块化设计,采用符合DIN EN 50446的标准接线盒和客户指定的浸入长度,灵活性高
芯子兼容性高,设计符合DIN 43772标准
高精确度、超长稳定性
头部变送器选择容易:模拟输出4至20 mA、HART®、PROFIBUS® PA或 FF现场总线
附件 / 备件 16
共 16 项备件 · 点击收起
| 订货号 | 名称 / 说明 | |
|---|---|---|
| TA30A- | 接线盒 TA30ARetainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing). | 询价 |
| TMT82- | 温度变送器 TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. | 询价 |
| TMT82- | 温度变送器 TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. | 询价 |
| TMT84- | 温度变送器 TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable. | 询价 |
| TMT85- | 温度变送器 TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose. | 询价 |
| TMT84- | 温度变送器 TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable. | 询价 |
| TMT85- | 温度变送器 TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose. | 询价 |
| 71044061 | 设备包2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector | 查看详情 |
| TXU10- | 仪表调试包 TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线 | 询价 |
| FXA195- | 通讯接口 FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508. | 询价 |
| READWIN- | Readwin 2000调试包 READWINReadwin 2000 Operation + Read. software | 询价 |
| TMT82- | 温度变送器 TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. | 询价 |
| TMT180- | ***模块温度变送器 TMT180Product Phased Out. Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed. | 询价 |
| TMT181- | ***iTEMP TMT181, Head Transmitter PCPProduct being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed. | 询价 |
| TMT182- | ***模块温度变送器 TMT182Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, SIL2, galvanic isolation Fault reaction: NAMUR NE 43. Mounting: head form B, DIN43729. UL listed. GL (German Llyod) Marine. | 询价 |
| TMT184- | ***iTEMP TMT184, headtransmitter PATemperature transmitter, Profibus-PA. Application: RTD, TC, Ohm, mV. Galvanic isolation. Profil V3.0. Curr. consumption 11mA Mounting: head form B, DIN43729. | 询价 |
型号配置 / 参数对比
测量原理视频
点击播放说明书下载 3
查看该型号全部资料服务案例
市政污水处理 · 热电阻应用案例
项目概况
项目现场在城市污水处理厂的进水、生化与出水工段。客户希望在既有装置上完善热电阻配置,核心诉求是以铂电阻元件做高精度温度测量。
技术难点
真正麻烦的是:污水中含固率高、含腐蚀性组分,昼夜水量波动大,并且出水指标波动、探头易被污泥与生物膜覆盖。这些都要求热电阻在配置时按精度等级、线制与插深选 Pt100 / Pt1000。
配置方案
按温度测量组织供货与实施:按测温点位置与响应要求做温度方案。现场按精度等级、线制与插深选 Pt100 / Pt1000,并逐条核对:出水须稳定达到一级 A 标准并联网上传数据。
投运表现
完成调试后,低温段精度优势明显,工艺窗口更可控,测量数据可直接用于工艺调整与考核。
食品饮料 · 热电阻应用案例
现场工况
该客户属于食品饮料行业,生产装置位于配料、杀菌、灌装与 CIP 清洗工段。项目的主要任务就是以铂电阻元件做高精度温度测量。
需要解决的问题
难点在于介质多为糖浆、乳品与饮料等易结垢物料,卫生级要求高;与此同时清洗频繁,仪表必须耐受 CIP/SIP 高温碱洗。选型上必须按精度等级、线制与插深选 Pt100 / Pt1000。
我们的做法
我们采用温度测量的交付思路 — 按测温点位置与响应要求做温度方案。实施时按精度等级、线制与插深选 Pt100 / Pt1000,同时逐项校验:须满足食品安全与卫生级(3-A / EHEDG)要求。
运行结果
系统投运以来表现稳定,日常维护量明显减少 — 低温段精度优势明显,工艺窗口更可控。
化工制药 · 热电阻应用案例
应用背景
反应釜、计量罐与成品储罐区是化工制药行业的典型工况。项目以热电阻为切入点,重点是以铂电阻元件做高精度温度测量。
工况约束
强腐蚀与防爆双重约束,仪表寿命短、停机维护成本高,而介质腐蚀性强、常带溶剂与结晶,部分区域为爆炸性环境的条件又进一步放大了这一点。因此热电阻必须按精度等级、线制与插深选 Pt100 / Pt1000。
交付方案
交付按温度测量来组织 — 按测温点位置与响应要求做温度方案。实施中按精度等级、线制与插深选 Pt100 / Pt1000,同时满足需满足防爆认证与 GMP 数据可追溯要求。
使用效果
运行结果表明:低温段精度优势明显,工艺窗口更可控,该测点的测量置信度明显提高。
电力能源 · 热电阻应用案例
客户情况
电力能源行业的典型场景是锅炉给水、汽机凝结水与脱硫脱硝系统。本次测量对象为热电阻,工作重点是:以铂电阻元件做高精度温度测量。
面临的难点
现场工况为高温高压,蒸汽与含盐水并存,加上高温高压下测量漂移,非计划停机代价极高,常规配置很难长期胜任。方案需要按精度等级、线制与插深选 Pt100 / Pt1000。
实施方式
方案由温度测量落地:按测温点位置与响应要求做温度方案。技术要点在于按精度等级、线制与插深选 Pt100 / Pt1000,并确保符合:需满足电力行业规程与机组可用率指标。
客户收益
实际效果上,低温段精度优势明显,工艺窗口更可控,现场运维人员的工作负担随之下降。