产品概述
| Accuracy | ± 5% or ± 0.04 mg/L (whichever is greater) from 0 - 5 mg/L Cl₂ ± 10% from 5 - 10 mg/L Cl₂ |
| Air Purge | Optional with 3/8-inch quick-connect fitting and tubing; 0.003 m3/min at 1.38 bar (20 psig) maximum |
| Alerts | Low and high chlorine. Dirty cell. Low and high sample flow. |
| Certifications | CE compliant with: EN 61326-1, CISPR 11, EN 50581 ACMA RCM South Korea KC Certificate North America: FCC Supplier’s Declaration of Conformance, IEC/EN 60529, ICES-003 |
| Controller Compatibility | SC200, SC1000, SC4500. All controllers sold separately |
| Cycle Time | 2.5 minutes |
| Dimensions (H x W x D) | 342 mm x 329 mm x 177 mm |
| Drain | ½-inch ID flexible hose |
| Enclosure Rating | IP66 |
| Inlet | ¼-inch OD polyethylene tube, quick-disconnect fitting |
| Inlet Pressure | 0.3 - 5.2 bar (4.5 - 75 psig) supplied to Y-strainer 0.1 - 0.3 bar (1.5 - 5 psig) supplied to analyzer |
| Installation Kit | Pressure Regulator Installation Kit |
| Interferences | Other oxidizing agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference. Hardness must not exceed 1,000 mg/L CaCO₃. |
| Light Source | LED, measurement at 510 nm, 1 cm light pathlength |
| Lower Limit of Detection (LOD) | 0.03 mg/L |
| Mounting | Wall mount |
| Operating Humidity | 0 - 90% relative humidity, non-condensing |
| Operating Temperature Range | 5 - 40 °C (41 - 104 °F) |
| Parameter | Chlorine, free; Chlorine, total residual |
| Power Requirements (Voltage) | 12 VDC, 400 mA maximum (supplied by the controller) |
| Range | 0 -10 mg/L Cl₂ |
| Reagent Consumption | 0.5 L of buffer solution and 0.5 L of indicator solution in 31 days |
| Sample Flow Rate | 60 - 200 mL/min through the instrument |
| Sample Requirements | Y-strainer filtration with 40-mesh screen or higher |
| Sample Temperature | 5 - 40 °C (41 - 104 °F) |
| Warranty | 12 months |
| Weight | 4.1 kg (9.0 lbs.) |
| What's included? | CL17sc Chlorine Analyser with Pressure Regulator Installation Kit, and User Manual. User provides screws and/or anchors for mounting. Hach SC Controller and Reagents are not included, they are sold separately. |
服务案例
市政污水处理 · 哈希现货配置案例
应用背景
城市污水处理厂的进水、生化与出水工段是市政污水处理行业的典型工况。项目以哈希为切入点,重点是以 Hach 系列试剂与仪表完成水质分析。
工况约束
出水指标波动、探头易被污泥与生物膜覆盖,而污水中含固率高、含腐蚀性组分,昼夜水量波动大的条件又进一步放大了这一点。因此哈希必须按方法标准(分光光度法/滴定法)与量程选试剂。
交付方案
交付按现货中心来组织 — 从现货库存中直接配置并快速交付。实施中按方法标准(分光光度法/滴定法)与量程选试剂,同时满足出水须稳定达到一级 A 标准并联网上传数据。
使用效果
运行结果表明:方法一致性好,历史数据可纵向比较,该测点的测量置信度明显提高。
食品饮料 · 哈希现货配置案例
客户情况
食品饮料行业的典型场景是配料、杀菌、灌装与 CIP 清洗工段。本次测量对象为哈希,工作重点是:以 Hach 系列试剂与仪表完成水质分析。
面临的难点
现场工况为介质多为糖浆、乳品与饮料等易结垢物料,卫生级要求高,加上清洗频繁,仪表必须耐受 CIP/SIP 高温碱洗,常规配置很难长期胜任。方案需要按方法标准(分光光度法/滴定法)与量程选试剂。
实施方式
方案由现货中心落地:从现货库存中直接配置并快速交付。技术要点在于按方法标准(分光光度法/滴定法)与量程选试剂,并确保符合:须满足食品安全与卫生级(3-A / EHEDG)要求。
客户收益
实际效果上,方法一致性好,历史数据可纵向比较,现场运维人员的工作负担随之下降。
化工制药 · 哈希现货配置案例
项目背景
反应釜、计量罐与成品储罐区。本次项目围绕哈希展开,要解决的核心问题是:以 Hach 系列试剂与仪表完成水质分析。
工况挑战
现场介质与工况的特点是介质腐蚀性强、常带溶剂与结晶,部分区域为爆炸性环境,而且强腐蚀与防爆双重约束,仪表寿命短、停机维护成本高。因此哈希不能照搬通用配置,按方法标准(分光光度法/滴定法)与量程选试剂。
解决方案
阿仪科技技术团队按现货中心的方式推进:从现货库存中直接配置并快速交付。配置上按方法标准(分光光度法/滴定法)与量程选试剂,并同步对照:需满足防爆认证与 GMP 数据可追溯要求。
实施效果
投运后系统运行稳定,实际效果是:方法一致性好,历史数据可纵向比较。
电力能源 · 哈希现货配置案例
项目概况
项目现场在锅炉给水、汽机凝结水与脱硫脱硝系统。客户希望在既有装置上完善哈希配置,核心诉求是以 Hach 系列试剂与仪表完成水质分析。
技术难点
真正麻烦的是:高温高压,蒸汽与含盐水并存,并且高温高压下测量漂移,非计划停机代价极高。这些都要求哈希在配置时按方法标准(分光光度法/滴定法)与量程选试剂。
配置方案
按现货中心组织供货与实施:从现货库存中直接配置并快速交付。现场按方法标准(分光光度法/滴定法)与量程选试剂,并逐条核对:需满足电力行业规程与机组可用率指标。
投运表现
完成调试后,方法一致性好,历史数据可纵向比较,测量数据可直接用于工艺调整与考核。







