CL17sc chlorine analyzer with pressure regulator installation kit
HACH 8572400
CL17sc Free (Total) Chlorine Analyzer with Pressure Regulator Installation Kit, w/o Reagents CL17sc Colorimetric Chlorine Analyzer with Pressure Regulator Installation Kit, w/o Reagents

产品概述

Accuracy ± 5% or ± 0.04 mg/L (whichever is greater) from 0 - 5 mg/L Cl₂
± 10% from 5 - 10 mg/L Cl₂
Air Purge Optional with 3/8-inch quick-connect fitting and tubing; 0.003 m3/min at 1.38 bar (20 psig) maximum
Alerts Low and high chlorine. Dirty cell. Low and high sample flow.
Certifications CE compliant with: EN 61326-1, CISPR 11, EN 50581
ACMA RCM
South Korea KC Certificate
North America: FCC Supplier’s Declaration of Conformance, IEC/EN 60529, ICES-003
Controller Compatibility SC200, SC1000, SC4500. All controllers sold separately
Cycle Time 2.5 minutes
Dimensions (H x W x D) 342 mm x 329 mm x 177 mm
Drain ½-inch ID flexible hose
Enclosure Rating IP66
Inlet ¼-inch OD polyethylene tube, quick-disconnect fitting
Inlet Pressure 0.3 - 5.2 bar (4.5 - 75 psig) supplied to Y-strainer
0.1 - 0.3 bar (1.5 - 5 psig) supplied to analyzer
Installation Kit Pressure Regulator Installation Kit
Interferences Other oxidizing agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference. Hardness must not exceed 1,000 mg/L CaCO₃.
Light Source LED, measurement at 510 nm, 1 cm light pathlength
Lower Limit of Detection (LOD) 0.03 mg/L
Mounting Wall mount
Operating Humidity 0 - 90% relative humidity, non-condensing
Operating Temperature Range 5 - 40 °C (41 - 104 °F)
Parameter Chlorine, free; Chlorine, total residual
Power Requirements (Voltage) 12 VDC, 400 mA maximum (supplied by the controller)
Range 0 -10 mg/L Cl₂
Reagent Consumption 0.5 L of buffer solution and 0.5 L of indicator solution in 31 days
Sample Flow Rate 60 - 200 mL/min through the instrument
Sample Requirements Y-strainer filtration with 40-mesh screen or higher
Sample Temperature 5 - 40 °C (41 - 104 °F)
Warranty 12 months
Weight 4.1 kg (9.0 lbs.)
What's included? CL17sc Chlorine Analyser with Pressure Regulator Installation Kit, and User Manual. User provides screws and/or anchors for mounting.
Hach SC Controller and Reagents are not included, they are sold separately.
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hach — Stock Configuration Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Hach, focusing on water analysis with Hach reagents and instruments.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Hach specification must therefore cover choosing reagents by method standard (colorimetric or titration) and range.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on choosing reagents by method standard (colorimetric or titration) and range, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — method consistency that lets historical data be compared over time, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Hach — Stock Configuration Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Hach; the focus is water analysis with Hach reagents and instruments.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing reagents by method standard (colorimetric or titration) and range.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on choosing reagents by method standard (colorimetric or titration) and range, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means method consistency that lets historical data be compared over time, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hach — Stock Configuration Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Hach and the core task is water analysis with Hach reagents and instruments.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Hach cannot be specified generically — it calls for choosing reagents by method standard (colorimetric or titration) and range.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves choosing reagents by method standard (colorimetric or titration) and range, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is method consistency that lets historical data be compared over time.

Power & Energy

Power & Energy · Hach — Stock Configuration Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Hach properly configured on the existing plant, with the aim of water analysis with Hach reagents and instruments.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Hach configuration has to involve choosing reagents by method standard (colorimetric or titration) and range.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant choosing reagents by method standard (colorimetric or titration) and range, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is method consistency that lets historical data be compared over time, and the readings are now used for process tuning.