Приборы · Инжиниринг · Комплектация · ПЛК
0755-82221901 sales@ainstru.com

EZ1027.9700140T

EZ1027.9700140T
Семейство продуктов: EZ sc Metal Analyzers
EZ1027sc Nickel Colorimetric Analyzer, 1 stream, 4x mA Output
HACH EZ1027.9700140T
Reliable, Scalable Systems Designed for Peak Performance

产品概述

Reliable, Scalable Systems Designed for Peak Performance

The EZ1027sc Nickel analyzer, compatible with the SC4500 Controller, provides precise monitoring of nickel in water for efficient process control and regulatory compliance. Integration with the SC4500 improves data management and supports better decision-making. With reliable design and real-time measurements, this analyzer streamlines operations and ensures smooth workflows. Key Features Flexible Customisation The EZ1027sc Nickel analyzer meets the monitoring needs of any facility. The standard model supports a single stream with 4x mA outputs, while an upgrade offers 8x mA outputs for added flexibility. It can monitor up to eight streams, making it ideal for complex setups. With protocols like Modbus RTU, Modbus TCP/IP, Profibus DP, and Ethernet/IP, it integrates easily into existing systems. Its customisable features ensure accurate nickel monitoring for both routine and detailed analyses. Reliable and Easy to Use Designed for simplicity and accuracy, the EZ1027sc Nickel analyzer features an intuitive user interface and durable construction. It minimises operational complexity, helping your team consistently achieve dependable results with ease. Explore Tailored Solutions Your operations have specific demands, and we’re dedicated to helping you meet them. Contact our experts to explore how the EZ1027sc Nickel analyzer can be configured to enhance your nickel monitoring processes. Together, we’ll develop a solution tailored to your objectives, ensuring efficiency and long-term success.

主要特点

  • Trusted Equipment for Critical Operations:The EZ sc Series combines robust engineering with high-quality materials to ensure reliability 24/7. Designed for long-term performance, EZ sc Series minimizes breakdowns and supports sustained operational success.
  • Scalable Solutions for Growing Needs:Built to evolve alongside your needs, online analysers from the EZ sc Series offer adaptable parameters and easier integration. They ensure your facility remains future proof without requiring expensive upgrades. Easily adjust parameter testing ranges and expand sample streams to accommodate innovation and growth.
  • Real-Time Data for Faster Decisions:The EZ sc Series offers advanced connectivity and real-time monitoring, delivering immediate access to actionable insights. Facilities utilising this technology benefit from improved reaction times, empowering more informed decision-making and quicker responses during critical situations.
  • Simplified Troubleshooting with Expert Support:Built-in diagnostics combined with secure remote data access make the EZ sc Series simplify issue resolution. Supported by a highly responsive team of experts, it ensures uninterrupted functionality and minimises operational downtime. By addressing and identifying issues early, EZ sc Series of online analysers helps prevent costly disruptions and repairs while maintaining system efficiency.
  • Clear Workflows for Predictable Outcomes:Standardized tools and guided workflows ensure consistent implementation and operation. The EZ sc Series minimizes miscommunication, sets clear expectations, and reduces process inconsistencies, driving greater efficiency.

技术参数

参数名称说明
Ambient Temperature50 - 86°F (10 - 30 °C) ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Analog OutputsActive 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard: 4, optional: 8
Automatic cleaningYes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
CalibrationAutomatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
CertificationsCE, ETL certified to UL and CSA safety standards, UKCA
Cycle TimeNo Dilution Default: 15 min. Continuous: 12 min. Internal Dilution Default: 20 min. Continuous: 15 min.
Demineralized WaterInternal dilution option: Rinse water & Dilution water
Digital OutputsProfibus DP or Modbus RTU
Dimensions (H x W x D)688 mm x 460 mm x 340 mm
DrainAtmospheric pressure, vented, min. Ø 32 mm
Earth ConnectionDry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Instrument AirDry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
InterferencesMetal ions, e.g., aluminium (III) (Al³⁺), bismuth (II) (Bi²⁺), cadmium (II) (Cd²⁺), chromium (III) (Cr³⁺), cobalt (II) (Co²⁺), copper (II) (Cu²⁺), iron (II) (Fe²⁺), iron (III) (Fe³⁺), lead (II) (Pb²⁺), manganese (II) (Mn²⁺), magnesium (II) (Mg²⁺), mercury (II) (Hg²⁺), palladium (II) (Pd²⁺), platinum (II) (Pt²⁺), silver (II) (Ag⁺), tin (II) (Sn²⁺) and zinc (II) (Zn²⁺). Large quantities of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere.
Lower Limit of Detection (LOD)No Dilution 0.005 - 0.25 mg/L Ni: 0.005 mg/L 0.01 - 0.5 mg/L Ni: 0.01 mg/L Internal Dilution 0.05 - 2.5 mg/L Ni: 0.05 mg/L 0.1 - 5 mg/L Ni: 0.1 mg/L 0.25 - 12.5 mg/L Ni: 0.25 mg/L 0.5 - 25 mg/L Ni: 0.5 mg/L 0.75 - 37.5 mg/L Ni: 0.75 mg/L 1 - 50 mg/L Ni: 1 mg/L
MaterialHinged part: Thermoform ABS, door: PMMA Wall section: Galvanized steel, powder coated
Measurement methodColorimetric
Measurement MethodColorimetric
Number of sample streamsStandard: 1 Optional accessory for 2, 4, or 8 sample streams
OutputsOptional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP
ParameterNickel
Power100 - 240 VAC, 50/60 Hz Max. power consumption: 120 VA
PrecisionBetter than 2% full scale range for standard test solutions
Protection ClassIP44
RangeNo Dilution 0.005 - 0.25 mg/L Ni 0.010 - 0.5 mg/L Ni Internal Dilution 0.050 - 2.5 mg/L Ni 0.100 - 5 mg/L Ni 0.250 - 12.5 mg/L Ni 0.500 - 25 mg/L Ni 0.750 - 37.5 mg/L Ni 1 - 50 mg/L Ni
Reagent RequirementsKeep Buffer between 50 - 77 °F (10 - 25 °C), all other between 50 - 86 °F (10 - 30 °C)
Relays5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)
Sample Flow Rate100 - 300 mL/min
Sample PressureBy external overflow vessel (open to atmospheric pressure)
Sample QualityMaximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Sample Temperature50 - 86 °F (10 - 30 °C)
ValidationAutomatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Warranty12 months
WeightMax. 77 lb (35 kg)
What's included?EZ1027sc Nickel Analyzer, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and Empty Containers for Reagents with Fittings

应用领域

Municipal Water

同系列其他配置

型号
EZ1001.9700140TEZ1001sc Aluminum Colorimetric Analyzer, 1 stream, 4x mA Output
EZ1004.9700140TEZ1004sc Boron Colorimetric Analyzer, 1 stream, 4x mA Output
EZ1009.9700140TEZ1009sc Chromium Colorimetric Analyzer, 1 stream, 4x mA Output
EZ1010.9700140TEZ1010sc Copper Colorimetric Analyzer, 1 stream, 4x mA Output
EZ1024.9700140TEZ1024sc Iron Colorimetric Analyzer, 1 stream, 4x mA Output
EZ1040.9700140TEZ1040sc Zinc Colorimetric Analyzer, 1 stream, 4x mA Output
EZ2709.970B140TEZ2709sc Total Chromium Colorimetric Analyzer, 1 stream, 4x mA Output
EZ2701.970B140TEZ2701sc Total Aluminum Colorimetric Analyzer, 1 stream, 4x mA Output
EZ2710.970B140TEZ2710sc Total Copper Colorimetric Analyzer, 1 stream, 4x mA Output
EZ2724.970B140TEZ2724sc Total Iron Colorimetric Analyzer, 1 stream, 4x mA Output
EZ2727.970B140TEZ2727sc Total Nickel Colorimetric Analyzer, 1 stream, 4x mA Output
EZ2740.970B140TEZ2740sc Total Zinc Colorimetric Analyzer, 1 stream, 4x mA Output
EZ1025.9700140TEZ1025sc Manganese Colorimetric Analyzer, 1 stream, 4x mA Output
EZ2725.970B140TEZ2725sc Total Manganese Colorimetric Analyzer, 1 stream, 4x mA Output

资料下载

Моделей: 15 · свернуть