产品概述
Reliable, Scalable Systems Designed for Peak Performance
The EZ2727sc Total Nickel Analyzer, complete with the innovative SC4500 Controller, provides a precise and dependable solution for monitoring nickel levels in water. Designed for industrial and wastewater facilities, this Analyzer addresses operational challenges such as inefficiencies and regulatory compliance. Its ease of integration and reliable performance help optimize processes while minimizing downtime, making it a trusted tool for critical applications. Key Features Flexible Customisation Adapt the EZ2727sc Total Nickel Analyzer to meet your operational needs. The base model supports 1 stream and 4x mA outputs, but it can be expanded to handle up to 8 streams and 8x mA outputs, providing scalability for future requirements. Advanced connectivity options—including Modbus RTU, Modbus TCP/IP, Profibus DP, and Ethernet/IP—enable seamless system integration, streamlining data collection and process efficiency. Reliable and Easy to Use Engineered for demanding environments, the EZ2727sc Total Nickel Analyzer delivers consistently accurate nickel measurements with minimal maintenance. Its intuitive interface reduces the complexity of operation, empowering operators to focus on maintaining plant efficiency. The durable construction and low-maintenance design ensure long-term reliability, even under rigorous conditions, minimising disruptions to your workflows. Explore Tailored Solutions Every facility has unique requirements, and the EZ2727sc Total Nickel Analyzer is designed to meet those challenges. Contact us today to discover how this adaptable solution can help you improve process efficiency, achieve compliance, and maintain operational excellence. Together, we’ll configure the right solution for your needs.
主要特点
- Trusted Equipment for Critical Operations:The EZ sc Series combines robust engineering with high-quality materials to ensure reliability 24/7. Designed for long-term performance, EZ sc Series minimizes breakdowns and supports sustained operational success.
- Scalable Solutions for Growing Needs:Built to evolve alongside your needs, online analysers from the EZ sc Series offer adaptable parameters and easier integration. They ensure your facility remains future proof without requiring expensive upgrades. Easily adjust parameter testing ranges and expand sample streams to accommodate innovation and growth.
- Real-Time Data for Faster Decisions:The EZ sc Series offers advanced connectivity and real-time monitoring, delivering immediate access to actionable insights. Facilities utilising this technology benefit from improved reaction times, empowering more informed decision-making and quicker responses during critical situations.
- Simplified Troubleshooting with Expert Support:Built-in diagnostics combined with secure remote data access make the EZ sc Series simplify issue resolution. Supported by a highly responsive team of experts, it ensures uninterrupted functionality and minimises operational downtime. By addressing and identifying issues early, EZ sc Series of online analysers helps prevent costly disruptions and repairs while maintaining system efficiency.
- Clear Workflows for Predictable Outcomes:Standardized tools and guided workflows ensure consistent implementation and operation. The EZ sc Series minimizes miscommunication, sets clear expectations, and reduces process inconsistencies, driving greater efficiency.
技术参数
| 参数名称 | 说明 |
|---|---|
| Ambient Temperature | 50 - 86 °F (10 - 30 °C) ± 4 °C deviation at 5 - 95% relative humidity (non-condensing) |
| Analog Outputs | Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard: 4, optional: 8 |
| Automatic cleaning | Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly |
| Calibration | Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced |
| Certifications | CE, ETL certified to UL and CSA safety standards, UKCA |
| Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 °C; pressure max. 0.5 bar |
| Cycle Time | No Dilution Default: 30 min. Continous: 28 min. Internal Dilution Default: 31 min. Continous 31 min. |
| Demineralized Water | Internal dilution option: Rinse water & Dilution water |
| Digital Outputs | Profibus DP or Modbus RTU |
| Dimensions (H x W x D) | 688 mm x 460 mm x 340 mm |
| Drain | Atmospheric pressure, vented, min. Ø 32 mm |
| Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm² |
| Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar |
| Interferences | Metal ions, e.g., aluminium (III) (Al3+), bismuth (II) (Bi2+), cadmium (II) (Cd2+), chromium (III) (Cr3+), cobalt (II) (Co2+), copper (II) (Cu2+), iron (II) (Fe2+), iron (III) (Fe3+), lead (II) (Pb2+), manganese (II) (Mn2+), magnesium (II) (Mg2+), mercury (II) (Hg2+), palladium (II) (Pd2+), platinum (II) (Pt2+), silver (II) (Ag+), tin (II) (Sn2+) and zinc (II) (Zn2+). Large quantities of color and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere. |
| IP Rating | IP44 |
| Lower Limit of Detection (LOD) | No Dilution 0.01 - 0.25 mg/L Ni(T): 0.01 mg/L 0.02 - 0.5 mg/L Ni(T): 0.02 mg/L Internal Dilution 0.1 - 2.5 mg/L Ni(T): 0.1 mg/L 0.2 - 5 mg/L Ni(T): 0.2 mg/L 0.5 - 12.5 mg/L Ni(T): 0.5 mg/L |
| Material | Hinged part: Thermoform ABS, door: PMMA Wall section: Galvanized steel, powder coated |
| Measurement method | Colorimetric measurement using DMG colour solution |
| Measurement Method | Colorimetric |
| Model | EZ2727sc |
| Number of sample streams | Standard: 1 Optional accessory for 2, 4, or 8 sample streams |
| Outputs | Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP |
| Parameter | Nickel, total |
| Power | 230 VAC, 50/60 Hz 120 VAC, 50/60 Hz Max. power consumption: 240 VA |
| Precision | Better than 3% full scale range for standard test solutions |
| Protection Class | IP44 |
| Range | No Dilution 0.01 - 0.25 mg/L Ni(T) 0.02 - 0.5 mg/L Ni(T) Internal Dilution 0.1 - 2.5 mg/L Ni(T) 0.2 - 5 mg/L Ni(T) 0.5 - 12.5 mg/L Ni(T) |
| Reagent Requirements | Keep Buffer between 50 - 77 °F (10 - 25 °C), all other between 50 - 86 °F (10 - 30 °C) |
| Relays | 5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150) |
| Sample Flow Rate | 100 - 300 mL/min |
| Sample Pressure | By external overflow vessel (open to atmospheric pressure) |
| Sample Quality | Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU |
| Sample Temperature | 50 - 86 °F (10 - 30 °C) |
| Validation | Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly |
| Warranty | 12 months |
| Weight | Max. 77 lb (35 kg) |
| What's included? | EZ2727sc Nickel Analyzer, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and Empty Containers for Reagents with Fittings |
应用领域
Municipal Water
同系列其他配置
| 型号 | |
|---|---|
| EZ1001.9700140T | EZ1001sc Aluminum Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1004.9700140T | EZ1004sc Boron Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1009.9700140T | EZ1009sc Chromium Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1010.9700140T | EZ1010sc Copper Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1024.9700140T | EZ1024sc Iron Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1027.9700140T | EZ1027sc Nickel Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1040.9700140T | EZ1040sc Zinc Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ2709.970B140T | EZ2709sc Total Chromium Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ2701.970B140T | EZ2701sc Total Aluminum Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ2710.970B140T | EZ2710sc Total Copper Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ2724.970B140T | EZ2724sc Total Iron Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ2740.970B140T | EZ2740sc Total Zinc Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ1025.9700140T | EZ1025sc Manganese Colorimetric Analyzer, 1 stream, 4x mA Output |
| EZ2725.970B140T | EZ2725sc Total Manganese Colorimetric Analyzer, 1 stream, 4x mA Output |
资料下载
- Maximum Insight with Minimal Effort : EZ sc verses EZ
- 최소한의 노력으로 최대의 효과 : EZ sc ~에 비해 EZ
- Máxima perceção com o mínimo de esforço : EZ sc em comparação com EZ
- Analisadores Online Série EZ
- Maximální přehled s minimálním úsilím : EZ sc vs. EZ
- Online analyzátory řady EZ
- Analyzer Seri EZ Online Solusi Lengkap
- Brochure EZ Series Online Analysers
Похожие
HACHSC1000 relay module for DIN-rail mounting, 4 Relays, max. 240V
HACHNP6000sc Phosphate Analyzers
Stainless Steel Chain Mount Kit
Mercury Thermometer, Celsius, -10 to 200°C
Mercury Thermometer, Fahrenheit, -30 to 120°F
CPVC Insertion Mounting Hardware 2", pHD Series
COVER-SERVICE REPLACEMENT