产品概述
The first maintenance-free optical oxygen sensor for nuclear power plants.
The Hach Orbisphere K1200 sensor is a high accuracy Luminescent Dissolved Oxygen (LDO) sensor that has been optimized for measurements in water processes in the power and steam industry. Designed for mechanical robustness to extend service life and optimize total cost of ownership, the sensor, combined with the Orbisphere Controllers, offers a new way to monitor dissolved oxygen in power plants. Based on good engineering practice the Orbisphere K1200 LDO sensor is suitable for nuclear plant application. Maintenance and operating costs are significantly reduced due to the absence of membrane and electrolyte and sensor accuracy is unaffected by process changes such as flow changes.
主要特点
- One calibration per year:One zero point calibration per year is all that is needed with the K1200 sensor. Traditional electrochemical (EC) sensors display significant drift after only a few months, demanding regular re-calibration and substantial operator time. Due to its luminescent technology, the K1200 sensor is designed for minimal drift, resulting in it being the most stable sensor with the longest calibration interval in the nuclear industry.
- No membranes = two minutes of maintenance:With no membranes to replace and no electrolyte solution to replenish, the K1200 is virtually maintenance-free requiring only two minutes of maintenance per year. Sensor accuracy is unaffected by process changes or low flow events with no polarization time, eliminating unnecessary operator interventions in radioactive zones. In addition, corrosive or hazardous chemicals are not required, making the annual task faster, easier and safer without reducing measurement precision.
- Low cost retrofit:The complete system consists of a Controller, a flow chamber, the K1200 Luminescent Dissolved Oxygen Sensor and a 312xx Hydrogen Sensor for parallel measurement. The sensor is compatible with Hach Orbisphere 28 mm flow chambers, eliminating the need for engineering changes. Installation is fast and easy and does not require special preparation.
- A new level of confidence:The K1200 optical sensor is the first to use luminescent measurement technology to measure low level oxygen in nuclear power plants. Since 1978, when the first patent on EC sensors was granted, Hach Orbisphere sensors have set the industry standard for oxygen measurement by delivering confidence to every water chemistry manager. The new K1200 maintains this tradition in the nuclear industry and offers significant operating and cost benefits.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ± 0.8 ppb or 2 % whichever is greater |
| Ambient Temperature | -5 - 50 °C (23 - 122°F) |
| Analog Outputs | 3 Smart 0/4 to 20 mA (500 Ohms) programmable as linear or tri-linear, configurable to send diagnostics or alarm informations. |
| Application | Nuclear |
| Calibration | Single point zero calibration with standard 99.999% nitrogen (quality 5.0) or equivalent oxygen free gas |
| Certifications | 2004/108/EC - EN 61326-1 |
| Communication Capabilities | 3 x 0/4-20 mA; RS485; Ethernet |
| Display Resolution | 0.1 ppb |
| Lower Limit of Detection (LOD) | 0.6 ppb |
| Mounting | 28 mm Orbisphere fitting |
| Parameter | Oxygen |
| Power Requirements (Voltage) | 100 - 230 VAC |
| Range | 0 - 2000 ppb dissolved O2 (DO) |
| Relays | Measurement board: 3 measurement alarm relays (1A-30 VAC or 0.5A-50 VDC), configurable to send diagnostics information. Main board: 1 system alarm relay (1A-30 VAC or 0.5A-50 VDC). |
| Repeatability | ± 0.4 ppb or 1 % whichever is greater |
| Reproducibility | ± 0.8 ppb or 2 % whichever is greater |
| Response Time | (90%) <10 s (gas phase); <30 s (liquid phase) |
| Sample Flow Rate | 50 - 300 mL/min |
| Sample Pressure | 1 - 20 bar absolute (14.5 - 290 psi) |
| Sample Temperature | -5 - 50°C (23 - 122°F) |
| Sensors | K1200 LDO |
| Storage Conditions | -5 °C - 100 °C |
| Temperature Range | Accurate from -5 - 50 °C (23 - 122 °F) Resistant - temperature from -5 - 100 °C (23 - 212 °F) |
| Warranty | 12 months |
| Weight Sensor | 0.6 |
| What's included? | K1200 Sensor only. Controller 510, sensor cable, flow-chamber or process connection must be ordered separately. |
应用领域
Boiler Water · Steam Cycle · Ultrapure Water
资料下载
- Practice report: Dissolved Oxygen Measurement in Power Plants
- Mesure de l’oxygène dissous dans les centrales électriques
- Medición de oxígeno disuelto en centrales de energía
- Connah's Quay Opts for Almost Zero Maintenance DO Monitors
- Connah’s Quay opta por monitores de OD que casi no necesitan mantenimiento
- Application Note: Increasing LDO Longevity in Brewing
- Practice report: Dissolved Oxygen Measurement in Power Plants
- Introduction to Hach Services
Похожие
HACHBench Service Partnership, LDO Model 2, 1 Service/Year
Replacement Protector for Clark DO sensor
HACHOrbisphere 510 Controller O₂ (EC), CO₂ (TC), Wall Mount, 100-240 VAC, 0/4-20mA, Ext. Press.
HACHField Service Partnership, 3100 LDO, 1 Service/Year
HACHBench Service Partnership, 3100 LDO, 1 Service/Year
HACHPocket Dissolved Oxygen (DO) Meter
HACHHach BioTector B7000i TOC Analyzer
HACH