TNT82106
Семейство продуктов: COD TNTplus Vial Tests, LR
Chemical Oxygen Demand (COD) TNTplus Vial Test, LR (3-150 mg/L COD), 150 Tests
HACH TNT82106
Chemical Oxygen Demand - Expert Low Range COD test made simple.

产品概述

Chemical Oxygen Demand - Expert Low Range COD test made simple.

Recommended COD test for wastewater effluent. The Chemical Oxygen Demand analysis provides important information for the water treatment process and is essential to calculate the BOD COD ratio in wastewater. Due to this, the COD is one of the most frequently analyzed wastewater parameters globally. Why should you use Hach TNTplus® COD tests? Hach TNTplus COD vial test reagents are incredibly simple to use and cut down significantly on waste generation compared to other COD test kits. TNT821 is based on Hach Method 8000 for virtually any type of water sample. Method 8000 is USEPA approved for wastewater analysis under 40 CFR 136.3 and based on Standard Methods 5220 D. Hach TNTplus COD vial tests are available in multiple ranges. TNT821 provides a result in the Low Range of 3 - 150 mg/L COD and is often used for Chemical Oxygen Demand measurement in wastewater effluent. Hach TNT821 does not require a separate blanking vial for further waste reduction and is compatible with our ezCOD Waste Recycling Service for further peace of mind. Make the switch to TNTplus COD reagents today! Method For determination of Chemical Oxygen Demand (COD) by the Reactor Digestion Method. Simply pipette in sample, digest, and read in your Hach Spectrophotometer. 6 x 25 tests. Recommended instruments DR3900 DR6000 DRB200 Benefits of Hach TNTplus COD test kits:

主要特点

  • Easy and safe handling:The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
  • No reagent blank necessary:The high quality of TNTplus® vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
  • Lot after lot - Be Right:Truecal™ with each vial includes the calibration data for each individual lot, reducing variation in results. This allows you to meet reporting standards and to perform proficiency testing with higher confidence.
  • Automatic method detection:The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
  • Documented shelf life and COA:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box.

技术参数

参数名称说明
Digestion RequiredYes
EPA compliantYes
InstrumentDR3900, DR4900, DR6000, DR1900, DR2800, DR3800, DR5000
Method NameReactor Digestion
Method Number8000
Number of tests150
ParameterCOD (Chemical Oxygen Demand)
PlatformTNT plus™
Range3 - 150 mg/L COD
TruecalYes

应用领域

Industrial Wastewater · Municipal Water