Семейство продуктов: Total Nitrogen & s-TKN TNTplus Vial Tests
Nitrogen (Total) TNTplus Vial Test, LR (1-16 mg/L N), 25 Tests
HACH TNT826
Expert Low Range Nitrogen test made simple.

产品概述

Expert Low Range Nitrogen test made simple.

Nitrogen TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. Hach Method 10208 determines Total Nitrogen in water and wastewater by the Persulfate Digestion Method with a range up to 16 mg/L N. Digestion occurs within the sealed vial which eliminates evaporation and nitrogen loss due to splatter.

主要特点

  • Easy and safe handling:The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
  • No reagent blank necessary:The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
  • Lot after lot - Be Right:Truecal™ with each vial includes the calibration data for each individual lot, reducing variation in results. This allows you to meet reporting standards and to perform proficiency testing with higher confidence.
  • Automatic method detection:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.
  • Documented shelf life and COA:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box.

技术参数

参数名称说明
Digestion RequiredYes
InstrumentDR3900, DR4900, DR6000, DR1900, DR2800, DR3800, DR5000
Method NamePersulfate Digestion
Method Number10208
Number of tests25
ParameterNitrogen, Total
PlatformTNT plus™
Range1 - 16 mg/L N
Sample RequirementsThe pH of the water sample must be between pH 3 - 12. The temperature of the water sample and reagents must be between 15 - 25 °C (59 - 77 °F).
TruecalYes

同系列其他配置

型号
TNT880Simplified TKN (s-TKN) TNTplus Vial Test (0-16 mg/L N), 25 Tests
TNT827Nitrogen (Total) TNTplus Vial Test, HR (5-40 mg/L N), 25 Tests
TNT828Nitrogen (Total) TNTplus Vial Test, UHR (20-100 mg/L N), 25 Tests
TNT818Nitrogen (Total) TNTplus Vial Test, UHR (100-250 mg/L N), 25 Tests