Семейство продуктов: Total Nitrogen & s-TKN TNTplus Vial Tests
Simplified TKN (s-TKN) TNTplus Vial Test (0-16 mg/L N), 25 Tests
HACH TNT880
Expert Total Kjeldahl Nitrogen test made simple.

产品概述

Expert Total Kjeldahl Nitrogen test made simple.

Total Kjeldahl Nitrogen TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results. Hach Method 10242 Revision 1.2 (Simplified Spectrometric Measurement of Total Kjeldahl Nitrogen in Water and Water) is a USEPA Equivalent Method under 40 CFR 136.6 (Method Modifications and Analytical Requirements) that is compliant for the purposes of NPDES regulatory monitoring and reporting under the Clean Water Act. Please check with your local regulator for use under NPDES discharge permit. Hach Method 10242 provides two results, Total Nitrogen and Total Nitrate (combined Nitrate and Nitrite) that are used for the quantification of Total Kjeldahl Nitrogen. Unique vial reagent system digests the sample at 120 °C, increasing safety while eliminating ammonia contamination and the need to clean glassware. TNT880 has a range up to 16 mg/L TKN.

主要特点

  • Easy and safe handling:The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
  • No reagent blank necessary:The high quality of TNTplus® vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
  • Lot after lot - Be Right:Truecal™ with each vial includes the calibration data for each individual lot, reducing variation in results. This allows you to meet reporting standards and to perform proficiency testing with higher confidence.
  • Automatic method detection:The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
  • Documented shelf life and COA:New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box.

技术参数

参数名称说明
Digestion RequiredYes
EPAEqivalent under 40 CFR 136.6
EPA compliantYes
InstrumentDR3900, DR4900, DR6000, DR1900, DR2800, DR3800, DR5000
Method NameSimplified TKN (s-TKN™)
Method Number10242
Number of tests25
ParameterNitrogen, Simplified Total Kjeldahl
PlatformTNT plus™
Range0 - 16 mg/L N
Sample RequirementsThe pH of the water sample must be between pH 3 - 10. The temperature of the water sample and reagents must be between 15 - 25 °C (59 - 77 °F).
TruecalYes

同系列其他配置

型号
TNT826Nitrogen (Total) TNTplus Vial Test, LR (1-16 mg/L N), 25 Tests
TNT827Nitrogen (Total) TNTplus Vial Test, HR (5-40 mg/L N), 25 Tests
TNT828Nitrogen (Total) TNTplus Vial Test, UHR (20-100 mg/L N), 25 Tests
TNT818Nitrogen (Total) TNTplus Vial Test, UHR (100-250 mg/L N), 25 Tests