jt33 tdlas gas analyzer 诊断代码
共 93 条诊断代码 · 来源手册 BA02297CZH_0324.pdf
对应产品:Газоанализатор (查看参数与选型)
| 代码 | 信号 | 简述 | 行为 | 页码 |
|---|---|---|---|---|
| F082 | F | Data storage | Alarm | P112 |
| F083 | F | Memory content | Alarm | P112 |
| F100 | F | Laser off | Alarm | P112 |
| F101 | F | Laser off | Alarm | P112 |
| F103 | F | Laser temperature unstable | Alarm | P112 |
| F105 | F | Cell pressure connection defective | Alarm | P112 |
| F106 | F | Sensor (Optical Head) faulty | Alarm | P112 |
| F109 | F | Peak index @1 out of range | Alarm | P112 |
| F110 | F | Peak track adjustment exceeded | Alarm | P112 |
| F112 | F | Auto ramp adjustment exceeded | Alarm | P113 |
| F201 | F | Device failure | Alarm | P113 |
| F242 | F | Software incompatible | Alarm | P113 |
| F252 | F | Modules incompatible | Alarm | P113 |
| F262 | F | Sensor electronic connection faulty | Alarm | P113 |
| F270 | F | Main electronic failure | Alarm | P113 |
| F271 | F | Main electronic failure | Alarm | P113 |
| F272 | F | Main electronic failure | Alarm | P113 |
| F273 | F | Main electronic failure | Alarm | P113 |
| F275 | F | I/O module 1 to n defective | Alarm | P113 |
| F276 | F | I/O module 1 to n faulty | Alarm | P113 |
| F283 | F | Memory content | Alarm | P113 |
| F300 | F | Sensor electronics (ISEM) faulty | Alarm | P113 |
| F304 | F | MAC electronics connection faulty | Alarm | P114 |
| F305 | F | Solenoid @1 trigger error | Alarm | P114 |
| F306 | F | Heater temperature sensor | Alarm | P114 |
| F307 | F | Heater connection error | Alarm | P114 |
| F311 | F | Electr. failure | Alarm | P118 |
| F331 | F | Firmware update failed | Alarm | P114 |
| F332 | F | Writing in HistoROM backup failed | Alarm | P114 |
| F361 | F | I/O module 1 to n faulty | Alarm | P114 |
| F372 | F | Sensor electronics (ISEM) faulty | Alarm | P114 |
| F373 | F | Sensor electronic (ISEM) faulty | Alarm | P114 |
| F375 | F | I/O – 1 to n communication failed | Alarm | P114 |
| F382 | F | Data storage | Alarm | P114 |
| F383 | F | Memory content | Alarm | P114 |
| F387 | F | HistoROM data faulty | Alarm | P114 |
| F410 | F | Data transfer | Alarm | P114 |
| F437 | F | Configuration incompatible | Alarm | P115 |
| F520 | F | I/O 1 to n hardware configuration invalid | Alarm | P115 |
| F803 | F | Current loop @1 | Alarm | P115 |
| F908 | F | Cell pressure dry rescrub | Alarm | P116 |
| F909 | F | Cell pressure delta rescrub | Alarm | P116 |
| F910 | F | Cell temperature delta rescrub | Alarm | P116 |
| F911 | F | Detector reference level delta rescrub | Alarm | P116 |
| F912 | F | Fit ratio 2 rescrub | Alarm | P116 |
| F913 | F | Fit ratio 3 rescrub | Alarm | P116 |
| F914 | F | Fit residue rescrub | Alarm | P116 |
| F915 | F | Peak tracking rescrub | Alarm | P116 |
| F916 | F | Auto ramp rescrub | Alarm | P116 |
| F920 | F | Fit residue too low | Alarm | P116 |