The electromagnetic flowmeter 5W4C selection table is a commonly used configuration tool in industrial flow measurement. It defines various parameters of the instrument through a series of code combinations. A correct understanding of the selection table helps choose the most suitable model according to process requirements.

This article analyzes each option of the 5W4C selection table item by item and provides selection steps and suggestions to help you quickly complete the selection.

5W4C Selection Table Overview

Detailed Explanation of Selection Codes

Explosion-proof Certification

Select the explosion-proof rating according to the atmospheric conditions of the installation environment to ensure safety and compliance.

  • AA: Non-explosion-proof场合
  • C6: CSA C/US NI Cl.I Div.2 Gr. ABCD
  • GR: Non-explosion-proof + EAC marking
  • UR: UK; Non-explosion-proof场合

Design

The design options involve sensor structure, flange type, and straight pipe section requirements, which need to be selected according to pipeline conditions.

  • A: Short sensor end-face distance, ISO/DVGW until DN400, DN450-2000 1:1
  • B: Long sensor end-face distance, ISO/DVGW until DN400, DN450-2000 1:1.3
  • C: Short sensor end-face distance, ISO/DVGW reduced bore measuring tube, no upstream/downstream straight pipe installation requirements
  • D: Loose flange
  • E: Welded flange
  • F: Welded flange, short end-face distance type
  • G: Welded flange, long end-face distance type
  • H: Loose flange, no upstream/downstream straight pipe requirements
  • I: Welded flange, no upstream/downstream straight pipe requirements
  • J: Welded flange, short end-face distance type, no upstream/downstream straight pipe requirements
  • K: Welded flange, long end-face distance type, no upstream/downstream straight pipe requirements
  • 9: Special type, please define TSP number

Power Supply

Select the power supply type according to on-site power supply conditions.

  • L: AC 100...240V, AC/DC 24V
  • X: Sensor only
  • 9: Special type, please define TSP number

Output; Input

Output and input options determine the signal transmission method and communication protocol.

  • H: 4-20mA HART, pulse/frequency switch output
  • I: 4-20mA HART, 2x pulse/frequency/switch output; status input
  • J: 4-20mA HART, pulse output custody transfer switch output; status input
  • L: PROFIBUS DP
  • M: Modbus RS485
  • N: EtherNet/IP
  • O: Modbus RS485, 4-20mA, 2x pulse/frequency/switch output
  • P: Modbus RS485, 4-20mA, pulse output custody transfer, pulse/frequency/switch output
  • X: Sensor only
  • 9: Special type, please define TSP number

Housing

Housing material and installation method affect the protection rating and on-site adaptability.

  • A: Compact, aluminum housing, with anti-corrosion coating
  • M: Compact, polycarbonate
  • N: Remote, polycarbonate
  • P: Remote, aluminum housing, with anti-corrosion coating
  • Q: Compact, polycarbonate, with tilt
  • R: Compact, aluminum housing, with anti-corrosion coating, with tilt
  • 9: Special type, please define TSP number

Remote Cable

Remote transmitter requires selection of signal cable length and type.

  • 0: None
  • 1: 5m signal cable
  • 2: 10m signal cable
  • 3: 20m signal cable
  • 4: ..... m signal cable
  • 5: ..... ft signal cable
  • 6: ..... m armored signal cable
  • 7: ..... ft armored signal cable
  • 8: 30m armored signal cable
  • 9: Special type, please define TSP number

Electrical Connection

The electrical connection method must match the on-site cable interface.

  • A: Cable gland M20
  • B: Thread M20
  • C: Thread G1/2
  • D: Thread NPT1/2
  • L: Plug connector M12x1 + thread NPT1/2
  • N: Plug connector M12x1 + cable gland M20
  • P: Plug connector M12x1 + thread G1/2
  • U: Plug connector M12x1 + thread M20
  • X: Sensor only
  • 9: Special type, please define TSP number

Liner

Liner material must be selected according to medium corrosiveness and temperature.

  • H: Hard rubber
  • Q: PTFE 90oC
  • U: Polyurethane
  • 9: Special type, please define TSP number

Process Connection

Process connection options include flange standard, pressure rating, and material, and must match the pipeline flange.

CodeStandardPressure RatingMaterialFlange Type
A1KASME B16.5Cl.150Carbon steelFlange
A1SASME B16.5Cl.150Stainless steelFlange
A12ASME B16.5Cl.150Carbon steelLoose flange
A14ASME B16.5Cl.150Stainless steelLoose flange
A2KASME B16.5Cl.300Carbon steelFlange
A2SASME B16.5Cl.300Stainless steelFlange
D1KEN1092-1PN6Carbon steelFlange
D1SEN1092-1PN6Stainless steelFlange
D2KEN1092-1PN10Carbon steelFlange
D2SEN1092-1PN10Stainless steelFlange
D21EN1092-1PN10Carbon steelLoose flange plate type
D22EN1092-1PN10Carbon steelLoose flange
D23EN1092-1PN10Stainless steelLoose flange plate type
D24EN1092-1PN10Stainless steelLoose flange
D3KEN1092-1PN16Carbon steelFlange
D3SEN1092-1PN16Stainless steelFlange
D32EN1092-1PN16Carbon steelLoose flange
D34EN1092-1PN16Stainless steelLoose flange
D4KEN1092-1PN25Carbon steelFlange
D4SEN1092-1PN25Stainless steelFlange
D5KEN1092-1PN40Carbon steelFlange
D5SEN1092-1PN40Stainless steelFlange
M2KAS2129Table ECarbon steelFlange
M3KAS4087PN16Carbon steelFlange
N3KJIS B222010KCarbon steelFlange
N3SJIS B222010KStainless steelFlange
N4KJIS B222020KCarbon steelFlange
N4SJIS B222020KStainless steelFlange
W1KAWWA C207Cl.DCarbon steelFlange
999Special type, please define TSP number

Electrodes

Electrode material affects measurement accuracy and corrosion resistance.

  • G: 316L, bullet nose
  • H: Alloy C22, bullet nose
  • 0: 316L
  • 1: Alloy C22
  • 2: Tantalum electrode
  • 7: 316L, replaceable, only 2 measuring electrodes
  • 9: Special type, please define TSP number

Calibration Flow

Calibration options determine measurement accuracy and certification type.

  • A: 0.5%
  • B: 0.2%
  • D: 0.5%, 3-point, traceable ISO/IEC17025
  • E: 0.2%, 3-point, traceable ISO/IEC17025
  • F: 0.5% full range calibration
  • G: 0.2% full range calibration
  • H: MID type test certificate MI-001, sensor fully welded
  • K: OIML R49 Class 2, sensor fully welded
  • L: OIML R49 Class 1, sensor fully welded
  • M: 0.5%, 3-point
  • N: 0.2%, 3-point
  • 8: Special type, also meets custody transfer certification
  • 9: Special type, please define TSP number

Operating Language Display

Display language options, supporting multiple languages.

  • AA: English
  • AB: German
  • AC: French
  • AD: Spanish
  • AE: Italian
  • AF: Dutch
  • AG: Portuguese
  • AH: Polish
  • AI: Russian
  • AJ: Turkish
  • AK: Simplified Chinese
  • AL: Japanese
  • AM: Korean
  • AN: Arabic
  • AO: Indonesian
  • AP: Thai
  • AQ: Vietnamese
  • AR: Czech
  • AS: option not used AS
  • AT: Swedish

Display; Operation

Additional display and operation functions.

  • BA: WLAN
  • B9: Special type, please define TSP number

Sensor Options

Sensor protection rating and special application options.

  • CA: IP66/67, Type 4X, fully welded, anti-corrosion protection EN ISO 12944 C5-M
  • CB: IP68, Type 6P, factory potting, anti-corrosion protection EN ISO 12944 C5-M/Im1
  • CC: IP68, Type 6P, customer potting, anti-corrosion protection EN ISO 12944 C5-M/Im1
  • CD: Buried IP68, Type 6P, factory potting, anti-corrosion protection EN ISO 12944 Im2/3
  • CE: Buried IP68, Type 6P, customer potting, anti-corrosion protection EN ISO 12944 Im2/3
  • CF: Harsh working conditions
  • CQ: IP68, Type 6P, factory potting
  • CV: Suspended measurement
  • C3: IP66/67, Type 4X, fully welded, EN ISO 12944 C5-M
  • C9: Special type, please define TSP number

Factory Parameter Setting

Factory preset output and display parameters.

  • DA: Output 1
  • DB: Output 2
  • DH: Display; totalizer
  • D9: Special type, please define TSP number

Application Package

Optional application function packages to enhance instrument performance.

  • EA: Extended HistoROM
  • EB: Heartbeat verification + monitoring
  • EC: ECC electrode cleaning
  • E9: Special type, please define TSP number

Custody Transfer

Certification options for trade settlement.

  • GM: Liquid: water; MI-001
  • GN: Liquid: water; OIML R49 Class 1
  • GO: Liquid: water; OIML R49 Class 2
  • G9: option not used G9

Service

Documentation options.

  • I7: Product paper documentation
  • I8: Product documentation CD
  • I9: Special type, please define TSP number

Test, Certificate

Material and pressure test certificates.

  • JA: 3.1 material certificate (pipe + flange) EN10204-3.1 inspection certificate
  • JB: Pressure test certificate, internal pressure-bearing parts inspection certificate
  • KA: EN10204-2.1 declaration of conformity
  • KB: EN10204-2.2 test report
  • K9: Special type, please define TSP number

Other Certifications

Industry and regional certifications.

  • LC: PESR Cat. I/II/III
  • LD: CRN
  • LG: OIML R49 certificate
  • LK: PED Cat. I/II/III
  • L1: KTW/W270 drinking water certification
  • L2: WRAS BS6920 drinking water certification
  • L3: ACS drinking water certification
  • L4: NSF 61 drinking water certification
  • L5: NSF 61 drinking water + hot water certification
  • L9: Special type, please define TSP number
  • M1: TSG certificate/GC1
  • M2: TSG certificate/GC2
  • M9: Special type, please define TSP number

Other Accessories

Installation and protection accessories.

  • PA: Rain cover
  • PB: Sunshade
  • PC: Pipe mounting components
  • P9: Special type, please define TSP number

Firmware Version

Firmware version affects communication protocol and functions.

  • 66: 02.00.zz, EtherNet/IP, DevRev 04
  • 67: 02.00.zz, PROFIBUS DP, DevRev 03
  • 68: 02.01.zz, Modbus RS485, DevRev 05
  • 69: option not used 69
  • 70: 02.01.zz, HART, DevRev 09
  • 71: 02.00.zz, HART, DevRev 08
  • 72: 01.01.zz, PROFIBUS DP, DevRev 02
  • 73: 01.05.zz, HART, DevRev 06
  • 74: 01.01.zz, EtherNet/IP
  • 75: 01.00.zz, PROFIBUS DP, DevRev 01
  • 76: 01.04.zz, HART, DevRev 01
  • 77: 01.00.zz, EtherNet/IP
  • 78: 01.00.zz, Modbus RS485

Marking

Tag and bus address marking.

  • Z1: Tag (TAG), see additional notes
  • Z2: Bus address, see additional notes

Selection Steps and Suggestions

Follow these steps to quickly complete the selection:

  1. Confirm process conditions: medium, temperature, pressure, flow range, explosion-proof requirements, etc.
  2. Select liner and electrode material according to medium corrosiveness.
  3. Select process connection and design options according to pipeline standards.
  4. Select power supply, output, and firmware version according to power supply and communication requirements.
  5. Select housing, electrical connection, and sensor options according to installation environment.
  6. Select calibration, testing, and other certification options according to certification requirements.
  7. Check the selection codes to ensure compatibility of all options.

If there are special requirements, you can choose special type codes (such as 9, 999, etc.) and define the TSP number.

5W4C Selection Steps

Frequently Asked Questions (FAQ)

1. How to choose the explosion-proof rating?

Choose according to the hazardous gas classification of the installation area, e.g., select AA for non-explosion-proof场合, C6 for CSA certification.

2. How to choose the liner material?

Hard rubber is suitable for neutral media such as water, PTFE has strong corrosion resistance, and polyurethane has good wear resistance.

3. What is the difference between calibration accuracy 0.2% and 0.5%?

0.2% has higher accuracy and is suitable for trade settlement and other demanding occasions; 0.5% is suitable for general industrial measurement.

4. How to interpret the process connection code?

The first letter of the code indicates the flange standard, the number indicates the pressure rating, and the letter K/S indicates carbon steel/stainless steel.

5. How to handle special type options?

After selecting the special type code, provide the TSP number to specify the exact specifications.

Through the above analysis, we believe you can more efficiently complete the selection of the electromagnetic flowmeter 5W4C. If you need further assistance, please contact our technical support team.