卫生型温度计
Technical Data
CompareThermometer
| Measuring Principle | Resistance Temperature Detector |
| Characteristic / Application | imperial style hygienic applications aseptic applications hygienic process connections with neck |
| Thermowell / protection tube | without (direct immersion) |
| Insert / probe | without exchangeable insert |
| Outer diameter protection tube / Insert | 1/4'' (6,35 mm) 3/8'' (9,53 mm) |
| Max. immersion length on request | up to 15.5" (317,5mm) others on request |
| Material protection tube/ thermowell | 316L |
| Process connection | Triclamp Clamp-connections according to ISO2852 G3/4" Liquiphant G1" Liquiphant Varivent |
| Tip shape | straight reduced |
| Surface roughness Ra | 30 μin (0,76 μm) 15 μin (0,38 μm) |
| Operating temperature range | PT100: -50 °C … 200 °C (-58 °F … 392 °F) |
| Max. process pressure (static) | at 20 °C: 40 bar (580 psi) |
| Accuracy | class A acc. to IEC 60751 |
| Response time | depending on configuration |
| Integration head transmitter | yes (4 ... 20 mA, HART) |
| Certification | SIL (transmitter only) |
The iTHERM thermometer meets the basic requirements of the food & beverage and life sciences industries with maximum cost-effectiveness. A wide range of instrument versions is available, making product selection simple and fast while saving time and costs. The basic version features a non-replaceable fixed thermowell insert, a wide range of process connections and international approvals, at a highly attractive price.
Advantages
High cost-effectiveness and fast delivery
User-friendly and reliable from product selection through to maintenance
International approvals: complies with hygienic standards (3-A®, EHEDG, ASME BPE, FDA), TSE suitability certificate available
A wide range of process connections
Application areas
Designed specifically for hygienic and aseptic applications in the food & beverage and life sciences industries
Measuring range: –50...+200 °C (–8...+392 °F)
Maximum pressure: 40 bar (580 psi)
Maximum degree of protection: IP69K
Can be used in non-hazardous areas
E+H Product Model Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the input fields below; up to three products can be compared
Technical documentation
Technical data
Documents / Manuals / Software
Accessories / Spare parts
Source:Endress+Hauserpublic information from the website
Case Studies
市政污水处理污水处理厂 · 热电阻应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对热电阻的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 热电阻应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对热电阻的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 热电阻应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对热电阻的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 热电阻应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对热电阻的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。