CA80AM Liquiline System

CA80AM Liquiline System
Liquiline System CA80AM
Configurable Models 13 models
Liquiline System CA80AM offers high-precision ammonium measurement in all critical control points. As member of the Liquiline platform, it enables plug & play and easy upgrade to a measuring station - minimizing the installation effort. Automatic calibration and cleaning as well as the low consumption of reagents save you operating and maintenance costs. Advanced diagnostics with remote access ensure process safety and support you in providing process documentation to the authorities.
Compare

Analyser

Measuring Principle Colorimetric
Characteristic Analyzer for ammonium in aqueous solutions
Measuring method Comply with standard colorimetric measuring principle - indophenol blue method following ISO 7150-1, DIN 38406-5 and GB 7481-87
Size Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in
Design Open design / cabinet:
Plastic ASA-PC
Stand housing:
Plastic ASA-PC, steel coated
Process temperature 4 to 40 °C (39 to 104 °F)
Ambient temperature 5 to 40 °C (41 to 104 °F)
Outdoor version: - 20 to 40 °C (-4 to 104 °F)
Process pressure Unpressurized
Sample flow rate Min. 5 ml/min (0.17 fl.oz/min)
Consistency of the sample Low solids content
Turbitity < 50 NTU, aqueous, homogenized
Specials Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Optional cooling module for longer reagent life time
Automatic calibration and cleaning
Optional 2 channel version
User-definable measuring ranges
Flexibale functionality and modular expandable
Digital communication for remote access
Application Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants
Monitoring of the wastewater treatment plant outlet for documentation purposes
Monitoring and optimization of activated sludge basins
Power supply 100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1.2 Hz
Output / communication 2x 0/4 to 20 mA
Optional: Webserver, Modbus, Ethernet/IP, Profibus DP
Input 1 or 2 measuring channels
Optinonal 1 to 4 digital sensor inputs for sensors with Memosens protocol
Measuring range 0.05 to 20 mg/l NH4-N
0.5 to 50 mg/l NH4-N
1 to 100 mg/l NH4-N
0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l NH4-N
Consumables Reagents and standard solutions CY80AM
Cleaner CY800
Maintenance kit CAV800

The Liquiline System CA80AM performs high-precision ammonium measurement at all critical control points. As a member of the Liquiline platform, it is plug-and-play and can be easily upgraded to a measuring station - with minimal installation requirements. Automatic calibration and cleaning and low reagent consumption reduce operating and maintenance costs. Advanced diagnostics with remote access ensure process safety and provide process documentation for convenient process management.

  • Advantages

  • Convenient commissioning, plug and play thanks to Memosens technology and a user-friendly interface

  • Easy functional upgrade - even to a complete measuring station - by simply adding and connecting Memosens sensors

  • Advanced diagnostics with remote access increase process safety

  • Automatic calibration, automatic cleaning and an optional reagent cooling unit effectively reduce system maintenance and management costs

  • Standard colorimetric measuring principle - indophenol blue method - compliant with ISO 7150-1, DIN 38406-5 and GB 7481-87

  • Areas of application

  • The Liquiline System CA80AM monitors and controls:

  • Inlet of wastewater treatment plants

  • Outlet of wastewater treatment plants for documentation

  • Aeration basins

  • Water treatment

  • Purification capacity of municipal and industrial wastewater treatment plants

Spare Parts & Accessories 107

107 spare parts · click to collapse
Order codeDescription
CY80AM-Reagent / Standard CY80AMPremixed reagent set for CA80AM with long shelf life and/or standard solution for calibration/ajustment Contains dangerous goodsEnquire
CY800-Cleaning Solution CY800Cleaning solution for Liquiline System CA80 Contains dangerous goodsEnquire
CAV800-CAV800 Maintenance Tool KitKits with all maintenance parts for Liquiline System CA8x analyzers Content: dispensers, hoses, connectors, O-ring for the sample collector, filter mats. Optional: in-and outlet hoses(PA), Liquidmanager without motor (PT) or 2 sample collector beakers(PV)Enquire
CAC800-Liquiline System CAC800Sample hoses for Liquiline System with different lengthsEnquire
CAC880-CA8x inlet/outlet hose CAC880Inlet and outlet hoses for Liquiline System CA80 in heated and unheated version.Enquire
71101762CM442/CM444/CM448/CSF48 display cable accessoryCM44x/CSF48/CA8xDetails
71218400CA8x/CAT860 Accessories: Wall MountingDetails
71458285Mast kit with holder CA80, outdoorDetails
71218402CA8x/CAT860 accessory: baseDetails
71218409CA8x Accessory: Door with WindowDetails
71218419CA8x accessory: M12 digital sensor external socketDetails
71218425CA8x/CAT860 Accessory: Lock cylinderDetails
71218429CA8x/CAT860 Accessory: Door StopDetails
71218431outlet pipeDetails
71218433ValveDetails
71218403CAT860 Liquid Level DetectionDetails
71218434Reagent disk, without cooling moduleDetails
71218471Reagent disk with cooling moduleDetails
71218472Complete Liquid CollectorDetails
71218473CA8x accessories: analyzer standard configurationDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

13 models · click to collapse
Diagnostic codes(136 条)→
All documents for this model
6 documents · click to expand
BA

BA Liquiline System CA80AM Chinese

Rev. 0924 176 pages
Preview
BA

Memosens Chinese

Rev. 0822 208 pages
Preview
BA

BA Liquiline System CA80AM English

Rev. 0924 186 pages
Preview
BA

Memosens English

Rev. 0822 228 pages
Preview
TI

TI Liquiline System CA80AM Chinese

Rev. 0924 40 pages
Preview
TI

TI Liquiline System CA80AM English

Rev. 0924 40 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · EH-ONLINE — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted EH-ONLINE properly configured on the existing plant, with the aim of continuous water monitoring on the E+H online platform.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the EH-ONLINE configuration has to involve configured under one numbering scheme across platform protocols and sensors.

Configuration

Supply and installation were organised through the online water-analysis line: integrating around each online monitoring point. On site this meant configured under one numbering scheme across platform protocols and sensors, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is data flows through the platform, improving service and diagnostics, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · EH-ONLINE — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous water monitoring on the E+H online platform.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means configured under one numbering scheme across platform protocols and sensors.

What We Did

We took a online water-analysis line approach — integrating around each online monitoring point. Delivery was built around configured under one numbering scheme across platform protocols and sensors, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — data flows through the platform, improving service and diagnostics, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · EH-ONLINE — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from EH-ONLINE, focusing on continuous water monitoring on the E+H online platform.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The EH-ONLINE specification must therefore cover configured under one numbering scheme across platform protocols and sensors.

Delivery Approach

Delivery was handled as the online water-analysis line — integrating around each online monitoring point. Execution centred on configured under one numbering scheme across platform protocols and sensors, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — data flows through the platform, improving service and diagnostics, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · EH-ONLINE — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is EH-ONLINE; the focus is continuous water monitoring on the E+H online platform.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with configured under one numbering scheme across platform protocols and sensors.

Implementation

The scope ran through the online water-analysis line: integrating around each online monitoring point. Technically it hinges on configured under one numbering scheme across platform protocols and sensors, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means data flows through the platform, improving service and diagnostics, which cut the workload on the site maintenance team.